{"title":"Apollo Call Points","description":"\u003cp\u003eApollo call points are manual call points that start a fire alarm when operated by hand, plus their covers and keys. This page has the AlarmSense 55400-894APO red call point, certified to EN 54-11 for two-wire AlarmSense systems, a transparent clip-on hinged cover that must be lifted before a call point is operated, and a pack of 10 reset keys for Apollo XP95 call points.\u003c\/p\u003e","products":[{"product_id":"apollo-manual-call-point-reset-keys-pack-of-10-xp95-compatible-44251-176apo","title":"Apollo Manual Call Point Reset Keys, Pack of 10, XP95 Compatible 44251-176APO","description":"\u003cp\u003e\u003cstrong\u003ePack of 10 Apollo XP95 manual call point reset\/test keys (44251-176APO).\u003c\/strong\u003e Plastic reset keys allow authorised personnel to operate and reset Apollo XP95 manual call points for routine testing without breaking the glass element, reducing replacement glass costs and simplifying maintenance.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePack of 10 reset\/test keys for routine testing and resetting of Apollo XP95 manual call points.\u003c\/li\u003e\n  \u003cli\u003eDesigned to fit the new style Apollo XP95 manual call point reset mechanism.\u003c\/li\u003e\n  \u003cli\u003eHelps avoid breaking the glass element during tests, lowering ongoing maintenance costs.\u003c\/li\u003e\n  \u003cli\u003eLightweight plastic construction for repeated use by maintenance teams and installers.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eUse cases:\u003c\/strong\u003e Ideal for facilities maintenance teams, fire alarm installers and service contractors who carry out routine testing and reset operations on Apollo XP95 manual call points.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSafety \u0026amp; installation:\u003c\/strong\u003e Only authorised personnel should test or reset fire alarm devices. Follow your site fire safety procedures and the manufacturer’s installation and maintenance guidance.\u003c\/p\u003e","brand":"Apollo Fire","offers":[{"title":"-","offer_id":56594667176309,"sku":"44251-176APO","price":6.04,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/ITM002848_1.png?v=1768248646"},{"product_id":"manual-call-point-hinged-cover-transparent-clip-on-single-44251-189apo","title":"Manual Call Point Hinged Cover (Transparent), Clip-On Single 44251-189APO","description":"\u003cp\u003e\u003cstrong\u003eApollo 44251-189APO\u003c\/strong\u003e — transparent hinged cover for single Apollo manual (break‑glass) call points. The clip‑on clear lid must be lifted before the call point is operated, helping to reduce accidental or malicious activations while keeping the call point fully visible for inspection.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003eTransparent design maintains visibility of indicators and the glass\/panel\u003c\/li\u003e\n  \u003cli\u003eHinged lift‑to‑access lid reduces false activations\u003c\/li\u003e\n  \u003cli\u003eSimple clip‑on fitting — easy to install as an ancillary accessory\u003c\/li\u003e\n  \u003cli\u003eDesigned to fit Apollo-manufactured manual call points (single unit)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eUsage \u0026amp; installation:\u003c\/strong\u003e Intended as a protective accessory for Apollo manual call points. Installers should follow Apollo guidance and local regulations when fitting accessories to fire alarm devices. This product is an ancillary cover only — it does not alter the operation of the call point and does not replace any certified device or maintenance requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDisclaimer:\u003c\/strong\u003e Manufacturer datasheet with dimensions\/material not available on the product page consulted. For full technical data or official specification PDF, consult Apollo or authorised distributors. Ensure installation and maintenance are performed in accordance with applicable UK\/EU standards and site fire‑safety procedures.\u003c\/p\u003e","brand":"Apollo Fire","offers":[{"title":"-","offer_id":56595090473333,"sku":"44251-189APO","price":2.18,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/ITM002889_1.png?v=1768256587"},{"product_id":"apollo-fire-manual-call-point-55400-894apo","title":"Apollo Fire 55400-894APO manual call point, Red","description":"\u003cp\u003e\u003cstrong\u003eApollo Fire 55400-894APO is a manual call point.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBrand Information\u003c\/p\u003e\n\u003cp\u003eAlarmSense is a range of conventional fire detection and alarm products designed to be connected to the same pair of supply wires, making installation quicker and less expensive. AlarmSense has been developed to make the design and installation of a fire detection and alarm system easier and more economic for small to medium-sized buildings. The range also allows an existing system to be extended or modified if necessary.\u003c\/p\u003e\n\u003cp\u003eThis flexibility makes AlarmSense an excellent choice for use in HMOs (House in Multiple Occupation). As you would expect from Apollo, AlarmSense incorporates features that help reduce false alarms and patented technology to ensure the integrity of a system. The range also includes products, such as beacons, to help meet the requirements of the Disability Discrimination Act (DDA).\u003c\/p\u003e\n\u003cp\u003eElectrical Considerations\u003c\/p\u003e\n\u003cp\u003eThe AlarmSense Manual Call Point is designed to operate with Alarmsense compatible control panels. Operating Principles\u003c\/p\u003e\n\u003cp\u003eWhen activated, the AlarmSense Manual Call Point introduces a load onto the line, which is detected by the fire control panel. The fire control panel then increases the line voltage, which activates the sounders, the manual call point load is then removed. Mechanical Construction\u003c\/p\u003e\n\u003cp\u003eThe component parts of the call point are moulded in a robust fire retardant polycarbonate. Product Information\u003c\/p\u003e\n\u003cp\u003eThe AlarmSense Manual Call Point has been designed to operate on a loop of AlarmSense compatible two wire fire alarm systems. An alarm is initiated by pressing the resettable element. The manual call point signals to the Control and Indicating Equipment using zene voltages.\u003c\/p\u003e\n\u003cp\u003eAn alarm status is indicated through the rotation of the resettable element, displaying and yellow and black indication bars and a solid red LED. The manual call point can be easily reset from the front using the supplied reset key.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eResettable operating element\u003c\/li\u003e\n\u003cli\u003eEasy access, front reset mechanism\u003c\/li\u003e\n\u003cli\u003eErgonomic reset key\u003c\/li\u003e\n\u003cli\u003eEN 54-11 Certified\u003c\/li\u003e\n\u003cli\u003e170° viewable LED\u003c\/li\u003e\n\u003cli\u003eSuitable for semi flush or surface mounting\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57546005283189,"sku":"55400-894APO","price":18.92,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/55400-894APO.jpg?v=1788458364"},{"product_id":"apollo-conventional-manual-call-point-sc2900-001apo","title":"Apollo Conventional Manual Call Point, Resettable, EN 54-11, Red SC2900-001APO","description":"\u003cp\u003eThe Apollo SC2900-001APO is a manual call point for a zone of conventional fire detection devices. It suits installers and maintainers who want a resettable element in place of glass to change. Pressing the element starts the alarm, and the supplied reset key returns it to normal from the front.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eCan be reset, nothing to replace after a test – resettable operating element\u003c\/li\u003e\n\u003cli\u003eQuick to return to service – easy access, front reset mechanism with an ergonomic reset key\u003c\/li\u003e\n\u003cli\u003eClear when it has been operated – yellow and black indication bars and an illuminated solid red LED\u003c\/li\u003e\n\u003cli\u003eSeen from a wide angle – 170° viewable LED\u003c\/li\u003e\n\u003cli\u003eTwo electrical options in one unit – both 470Ω resistor and normally open clean contact\u003c\/li\u003e\n\u003cli\u003eCertified to the call point standard – EN 54-11 certified\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: Supply Voltage 18 V - 30 V dc. Dry contact only, rated 30 V DC at 2A.\u003c\/li\u003e\n\u003cli\u003eMounting: size 90 mm height x 90 mm width x 63 mm depth, weight 150 g.\u003c\/li\u003e\n\u003cli\u003eCabling: choose the 470Ω resistor option or the normally open clean contact option. The LED illuminates red only in 470Ω mode.\u003c\/li\u003e\n\u003cli\u003eCompatibility: designed for a zone of conventional fire detection devices.\u003c\/li\u003e\n\u003cli\u003eStandards: EN 54-11, CPR \u0026amp; TUV-Mark. Rated IP44.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eIs this call point resettable?\u003c\/h4\u003e\n\u003cp\u003eYes. It has a resettable operating element, reset from the front using the supplied reset key.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it have glass to break?\u003c\/h4\u003e\n\u003cp\u003eIt uses a resettable element. An alarm is initiated by pressing it.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWill the LED light in every wiring mode?\u003c\/h4\u003e\n\u003cp\u003eNo. The LED illuminates red only when the call point is operated in 470Ω mode.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it be used on an addressable system?\u003c\/h4\u003e\n\u003cp\u003eIt has been designed to operate on a zone of conventional fire detection devices, so check the panel's documentation before using it on any other system.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it be fitted outside?\u003c\/h4\u003e\n\u003cp\u003eIt is rated IP44, with an operating temperature of -40 °C to +70 °C. Check the position against both, and check with the maker before fitting it outside.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat is the contact rating?\u003c\/h4\u003e\n\u003cp\u003e30 V DC at 2A. The contact type is dry contact only.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57710600061301,"sku":"SC2900-001APO","price":9.54,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-sc2900-001apo-conventional-manual-call-point-angled-view.webp?v=1793615347"},{"product_id":"apollo-waterproof-manual-call-point-58200-951apo","title":"Apollo Waterproof Addressable Manual Call Point, Red with Isolator 58200-951APO","description":"\u003cp\u003eThe Apollo 58200-951APO is a waterproof manual call point for addressable fire alarm loops. It suits outdoor applications, and areas where water ingress or high humidity is a problem. This red version includes a short circuit isolator, is IP56 rated, and works with XP95, Discovery and CoreProtocol.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBuilt for wet places – IP56 rated, with an IP67 rated electronics enclosure\u003c\/li\u003e\n\u003cli\u003eKeeps working through a loop fault – a short circuit isolator ensures operation in the event of a short circuit fault\u003c\/li\u003e\n\u003cli\u003eNothing to replace after use – a resettable operating element\u003c\/li\u003e\n\u003cli\u003eSimple to put back – easy access, front reset mechanism with an ergonomic reset key\u003c\/li\u003e\n\u003cli\u003eQuick response – when activated it interrupts the polling cycle\u003c\/li\u003e\n\u003cli\u003eCopes with the cold – operating temperature -30°C to +70°C\u003c\/li\u003e\n\u003cli\u003eEasy to fit – captive screws for easy installation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: loop powered at 17-28V dc. Quiescent 100µA, alarm current 4mA with the LED on.\u003c\/li\u003e\n\u003cli\u003eMounting: 114mm height x 114mm width x 74mm depth. Apollo recommends cable entry from the bottom.\u003c\/li\u003e\n\u003cli\u003eCabling: 20 mm cable entries. Use IP rated cable glands, and tighten and seal all glands and blanking plugs.\u003c\/li\u003e\n\u003cli\u003eCompatibility: XP95, Discovery and CoreProtocol compatible. On a CoreProtocol panel the device behaves as Discovery, fire control panel dependant.\u003c\/li\u003e\n\u003cli\u003eStandards: EN 54-11, EN 54-17, CPR, BOSEC, ESC, FG, SBSC, VNIIPO \u0026amp; SAI.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan this call point go outdoors?\u003c\/h4\u003e\n\u003cp\u003eYes. It is intended for outdoor applications, and it is IP56 rated. That relies on correctly IP rated cable glands and sealed entries.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it have a built-in isolator?\u003c\/h4\u003e\n\u003cp\u003eYes. This is the isolated version, Part No. 58200-951, with a yellow LED to indicate isolator operation.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is it reset?\u003c\/h4\u003e\n\u003cp\u003eWith the reset key. Insert it into the front facing LED and turn clockwise until there is a positive click.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhich fire alarm protocols does it work with?\u003c\/h4\u003e\n\u003cp\u003eXP95, Discovery and CoreProtocol, depending on the fire control panel. Check your panel before ordering.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is the address set?\u003c\/h4\u003e\n\u003cp\u003eBy a seven-segment DIL switch, at the commissioning stage. A DIL switch is a small bank of on-off switches.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhich colour is it?\u003c\/h4\u003e\n\u003cp\u003eRed. A yellow version exists under a separate part number.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57711081750901,"sku":"58200-951APO","price":106.55,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-58200-951apo-waterproof-manual-call-point-front-angled-view.jpg?v=1793620318"},{"product_id":"apollo-intelligent-manual-call-point-sa5900-908apo","title":"Apollo Intelligent Manual Call Point with Isolator, Red SA5900-908APO","description":"\u003cp\u003eThe Apollo SA5900-908APO is an intelligent red call point for raising a fire alarm by hand on an addressable loop. It suits installers on XP95, Discovery or CoreProtocol systems. A built-in short circuit isolator protects the loop, and the resettable element resets from the front with the supplied key.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNothing to replace after a press – a resettable operating element, reset from the front with the supplied reset key\u003c\/li\u003e\n\u003cli\u003eClear to see it has been used – the element rotates to show yellow and black indication bars, with a solid red LED\u003c\/li\u003e\n\u003cli\u003eHelps keep the loop running – a short circuit isolator, shown by a solid yellow LED when operating\u003c\/li\u003e\n\u003cli\u003eVisible from the side – a 170° viewable LED\u003c\/li\u003e\n\u003cli\u003eFaster first fix – cabling goes to a removable terminal block\u003c\/li\u003e\n\u003cli\u003eTest before commissioning – a continuity link for cable insulation testing\u003c\/li\u003e\n\u003cli\u003eChoice of fixing – suitable for semi flush or surface mounting\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: loop powered, 17-35V DC. Alarm current (LED on) 4mA, max at 24V DC.\u003c\/li\u003e\n\u003cli\u003eMounting: suitable for semi flush or surface mounting, 90mm height x 90mm width x 63mm depth.\u003c\/li\u003e\n\u003cli\u003eCabling: E-Z fit connector system, with a removable terminal block and a continuity link for cable insulation testing.\u003c\/li\u003e\n\u003cli\u003eCompatibility: operates with compatible Apollo control equipment using XP95, Discovery and CoreProtocols.\u003c\/li\u003e\n\u003cli\u003eStandards: EN 54-11, EN 54-17, CPR and LPCB (red version only). IP44.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is it reset after activation?\u003c\/h4\u003e\n\u003cp\u003eWith the supplied reset key. Insert it into the front facing LED and turn clockwise until a positive click and reset occurs.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is the address set?\u003c\/h4\u003e\n\u003cp\u003eBy a DIL switch at the commissioning stage. A DIL switch is a small bank of on-off switches.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it have a built-in isolator?\u003c\/h4\u003e\n\u003cp\u003eYes. It incorporates a short circuit isolator, and a solid yellow LED shows when it is operating.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhich panels does it work with?\u003c\/h4\u003e\n\u003cp\u003eCompatible Apollo control equipment using XP95, Discovery or CoreProtocol. Check your panel uses one of these first.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it be used outside?\u003c\/h4\u003e\n\u003cp\u003eIt is rated IP44, but that alone does not make it an outdoor product. Check your specification if it will be exposed to the weather.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat do the LED colours mean?\u003c\/h4\u003e\n\u003cp\u003eSolid red shows alarm, flashing yellow a fault, flashing green a poll and solid yellow isolator operation.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57711101968757,"sku":"SA5900-908APO","price":35.45,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-sa5900-908apo-intelligent-manual-call-point-angled-view.png?v=1793621007"},{"product_id":"apollo-discovery-manual-call-point-with-isolator-58100-908apo","title":"Apollo Discovery Manual Call Point with Isolator, Addressable, Red 58100-908APO","description":"\u003cp\u003eThe Apollo Discovery 58100-908APO is a manual call point with isolator for addressable fire alarm loops. A person presses it to raise the alarm, and it interrupts the polling cycle for a very fast response. It suits Discovery systems and is XP95 and CoreProtocol compatible, with a resettable element in a red housing.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eResets without a new glass – a resettable operating element with a front reset mechanism\u003c\/li\u003e\n\u003cli\u003eRaises the alarm quickly – interrupts the polling cycle for a very fast response\u003c\/li\u003e\n\u003cli\u003eProtects the loop – the isolated version, with an amber\/yellow LED for a short-circuit either side\u003c\/li\u003e\n\u003cli\u003eQuick to commission – front facing accessible addressing and a seven-segment DIL switch\u003c\/li\u003e\n\u003cli\u003eEasy to spot in alarm – a 170º viewable LED indicator\u003c\/li\u003e\n\u003cli\u003eWiring can be proved early – a connector allows continuity testing before commissioning\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: 17 - 28 V dc from the loop. Quiescent 100 µA, power up surge 1 mA, 4 mA in alarm with the LED illuminated.\u003c\/li\u003e\n\u003cli\u003eMounting: 89mm wide x 93 mm high x 26.5 mm depth, with a backbox for surface mounting as standard. 110 g flush mounted, 160 g surface mounted.\u003c\/li\u003e\n\u003cli\u003eCabling: two-wire supply, polarity sensitive. Terminal block L1 -ve\/L2 +ve, with clip-on terminal blocks.\u003c\/li\u003e\n\u003cli\u003eCompatibility: Discovery (XP95 and CoreProtocol compatible).\u003c\/li\u003e\n\u003cli\u003eStandards: EN 54-11, EN 54-17: 2005 (isolated version), CPR, LPCB. IP24D.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it have an isolator?\u003c\/h4\u003e\n\u003cp\u003eYes. Part 58100-908 is the version with isolator. Part 58100-910 is the one without.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it need a new glass after use?\u003c\/h4\u003e\n\u003cp\u003eNo. It has a resettable element that resets from the front with the reset key.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan a protective lid be added?\u003c\/h4\u003e\n\u003cp\u003eYes, but check the standard first. Apollo warns the call point does not conform to EN54-11 when the hinged lid is fitted and secured with the locking tag.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it be surface mounted?\u003c\/h4\u003e\n\u003cp\u003eYes. A backbox for surface mounting comes as standard, and it weighs 160 g surface mounted.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it be tested from the panel?\u003c\/h4\u003e\n\u003cp\u003eYes. It responds to a test command with a value of 64, and the panel should recognise this as a test signal without raising a general alarm.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57714822250869,"sku":"58100-908APO","price":54.23,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-58100-908apo-discovery-manual-call-point-with-isolator-angled-front-view.jpg?v=1793701407"},{"product_id":"apollo-explosion-proof-manual-call-point-29600-508","title":"Apollo Conventional Explosion Proof Manual Call Point, IP66, ATEX 29600-508","description":"\u003cp\u003eThe Apollo 29600-508 is a conventional explosion proof manual call point for the control of fire and gas alarm systems in hazardous areas. It is approved for use in Zone 1, 2, 21 and 22, and is break-glass operated with a flap. Its aluminium housing is rated IP66.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFor hazardous areas – approved for use in Zone 1, 2, 21 and 22\u003c\/li\u003e\n\u003cli\u003eFamiliar in an emergency – break-glass operated with a flap\u003c\/li\u003e\n\u003cli\u003eBuilt for harsh places – marine grade copper-free LM6 aluminium housing\u003c\/li\u003e\n\u003cli\u003eResists corrosion – phosphated and powder coated anti-corrosion finish\u003c\/li\u003e\n\u003cli\u003eSealed against water and dust – IP66\u003c\/li\u003e\n\u003cli\u003eWide temperature range – operating temperature -40ºC to +55ºC\u003c\/li\u003e\n\u003cli\u003eRecognised approvals – EN 54-11, IECEx, ATEX, EAC, InMetro and Gost-R\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: 250 V ac max, 50 V dc max. Switch rated 5 A max at 250 V ac, 1 A max at 50 V dc.\u003c\/li\u003e\n\u003cli\u003eCabling: 2 x M20 top and 1 x M20 side entries, and the backbox can be rotated to supply 2 x bottom and 1 x side entries.\u003c\/li\u003e\n\u003cli\u003eMounting: weighs 0.8kg. 2 x Ex e nylon stopping plugs are supplied as standard.\u003c\/li\u003e\n\u003cli\u003eStandards: II 2 G Ex e d IIC T6 Gb, and II 2 D Ex t IIIC T60ºC Db.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhich hazardous zones is it approved for?\u003c\/h4\u003e\n\u003cp\u003eZone 1, 2, 21 and 22. Check the site's area classification against that before fitting it.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is it operated?\u003c\/h4\u003e\n\u003cp\u003eBy breaking the glass. It is break-glass operated with a flap.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it be used for a gas alarm?\u003c\/h4\u003e\n\u003cp\u003eYes. It is approved for the control of fire and gas alarm systems.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan the cable come in from below?\u003c\/h4\u003e\n\u003cp\u003eYes. The backbox can be rotated to supply 2 x bottom and 1 x side entries.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eIs it suitable for outdoor or marine sites?\u003c\/h4\u003e\n\u003cp\u003eIt suits harsh conditions, with an IP66 rating and a marine grade aluminium housing. Check the location against its -40ºC to +55ºC temperature range.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57723711258997,"sku":"29600-508","price":320.34,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-29600-508-explosion-proof-manual-call-point-front-angled-view.jpg?v=1793788759"},{"product_id":"apollo-manual-call-point-55100-001apo","title":"Apollo Conventional Manual Call Point, Indoor Red, Resettable 55100-001APO","description":"\u003cp\u003eThe Apollo 55100-001APO is a conventional manual call point, the push-to-operate device that lets a person raise a fire alarm by hand. This indoor red version has an easily resettable element rather than a break glass. It suits installers on conventional fire detection systems, comes with a backbox for surface mounting and complies with EN54–11:2001.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eQuick to reset – an easily resettable element rather than a break glass\u003c\/li\u003e\n\u003cli\u003eFaster to wire – all installation cabling is terminated at a terminal block, the Plug and Play concept\u003c\/li\u003e\n\u003cli\u003eReady to fix – supplied with a backbox for surface mounting\u003c\/li\u003e\n\u003cli\u003eMeets the call point standard – red version complies with EN54–11:2001\u003c\/li\u003e\n\u003cli\u003eA tough housing – moulded in polycarbonate or ABS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: maximum supply voltage 30VDC, switch rating 2A.\u003c\/li\u003e\n\u003cli\u003eMounting: indoor, on the backbox supplied for surface mounting. 93mm x 89mm x 59.5mm, 180g, IP rating 24D.\u003c\/li\u003e\n\u003cli\u003eCabling: all installation cabling is terminated at a terminal block.\u003c\/li\u003e\n\u003cli\u003eCompatibility: conventional fire detection systems, with a 470Ω resistor in series with a normally open switch contact.\u003c\/li\u003e\n\u003cli\u003eStandards: complies with EN54–11:2001 and EMC Directive 2004\/108\/EC.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes the 55100-001APO need replacement glass?\u003c\/h4\u003e\n\u003cp\u003eNo. It has an easily resettable element rather than a break glass.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is it reset after use?\u003c\/h4\u003e\n\u003cp\u003eInsert the test key into the bottom of the unit until it clicks into position, remove it, then push the front cover up until it clicks home.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it be used on an addressable system?\u003c\/h4\u003e\n\u003cp\u003eIt is designed for conventional fire detection systems. Addressable loops need an addressable call point on the panel's protocol.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it be fitted outside?\u003c\/h4\u003e\n\u003cp\u003eNo, this is the indoor version with an IP rating of 24D. Outdoor versions have their own part numbers.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat is inside it electrically?\u003c\/h4\u003e\n\u003cp\u003eA 470Ω resistor in series with a normally open switch contact, which is how it signals an alarm on the zone.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57723712373109,"sku":"55100-001APO","price":15.69,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-55100-001apo-manual-call-point-front-view.png?v=1793788901"},{"product_id":"apollo-outdoor-manual-call-point-55100-004apo","title":"Apollo Conventional Manual Call Point, Outdoor Yellow, IP67 55100-004APO","description":"\u003cp\u003eThe Apollo 55100-004APO is an outdoor yellow manual call point, a device that lets a person raise a signal by hand on a conventional system. It has an easily resettable element, an IP rating of 67 and a backbox for surface mounting.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOutdoor version – IP rating 67\u003c\/li\u003e\n\u003cli\u003eWorks across a wide temperature range – -25°C to +70°C\u003c\/li\u003e\n\u003cli\u003eQuick to reset – an easily resettable element rather than a break glass\u003c\/li\u003e\n\u003cli\u003eFaster to wire – all installation cabling is terminated at a terminal block\u003c\/li\u003e\n\u003cli\u003eA tough housing – moulded in polycarbonate or ABS\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: maximum supply voltage 30VDC, switch rating 2A.\u003c\/li\u003e\n\u003cli\u003eMounting: on the backbox supplied for surface mounting. 93mm x 97.5mm x 71mm, 350g, IP rating 67.\u003c\/li\u003e\n\u003cli\u003eCabling: all installation cabling is terminated at a terminal block.\u003c\/li\u003e\n\u003cli\u003eCompatibility: conventional \u003ca href=\"\/collections\/fire-alarm-systems\"\u003efire detection systems\u003c\/a\u003e, with a 470Ω resistor in series with a normally open switch contact.\u003c\/li\u003e\n\u003cli\u003eStandards: complies with EMC Directive 2004\/108\/EC. Where a specification calls for EN54–11:2001, choose a red version.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eIs the 55100-004APO approved to EN54-11?\u003c\/h4\u003e\n\u003cp\u003eThat approval is for the red version, so choose red where a fire alarm specification calls for EN54–11:2001.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat is a yellow call point used for?\u003c\/h4\u003e\n\u003cp\u003eYellow sets it apart from the red fire alarm version. Agree the colour and its meaning with the system designer.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it go outdoors?\u003c\/h4\u003e\n\u003cp\u003eYes. This is the outdoor version, with an IP rating of 67 and an operating range of -25°C to +70°C.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is it reset after use?\u003c\/h4\u003e\n\u003cp\u003eInsert the test key into the bottom of the unit until it clicks into position, remove it, then push the front cover up until it clicks home.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57723712405877,"sku":"55100-004APO","price":134.03,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-55100-004apo-outdoor-manual-call-point-front-view.jpg?v=1793788910"},{"product_id":"apollo-addressable-manual-call-point-with-isolator-55100-908apo","title":"Apollo XP95 Manual Call Point with Isolator, Addressable, Indoor Red 55100-908APO","description":"\u003cp\u003eThe Apollo XP95 55100-908APO is an isolating manual call point, the device that lets a person raise a fire alarm by hand, for a loop of intelligent fire detection devices. It suits installers on XP95, Discovery or CoreProtocol systems. It reports an alarm in under 0.2 seconds and has an easily resettable element.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFast alarm – interrupts the polling cycle and reports an alarm in under 0.2 seconds\u003c\/li\u003e\n\u003cli\u003eQuick to reset – an easily resettable element\u003c\/li\u003e\n\u003cli\u003eIsolating version – this is the isolating XP95 Manual Call Point\u003c\/li\u003e\n\u003cli\u003eFaster to wire – initial cabling goes to a terminal block that fits neatly into the back of the call point\u003c\/li\u003e\n\u003cli\u003eCheck wiring early – continuity link for wiring test before commissioning\u003c\/li\u003e\n\u003cli\u003eClear status – a single bi-coloured alarm LED, red when activated and amber\/yellow for a short circuit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: 17 V - 28 V dc. At 24 V: maximum quiescent current 100 µA, alarm LED on 4 mA.\u003c\/li\u003e\n\u003cli\u003eMounting: for indoor applications. 93 mm x 89 mm x 59.5 mm, 160g, designed to IP45.\u003c\/li\u003e\n\u003cli\u003eCabling: initial installation cabling is wired to a terminal block, with a continuity link for a wiring test before commissioning.\u003c\/li\u003e\n\u003cli\u003eCompatibility: XP95, Discovery and CoreProtocol compatible. Address set with a seven segment DIL switch.\u003c\/li\u003e\n\u003cli\u003eStandards: EN 54-11, with CPR, LPCB, SBSC, CCCf.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes the 55100-908APO have an isolator?\u003c\/h4\u003e\n\u003cp\u003eYes. It is the isolating version of the XP95 Manual Call Point.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow quickly does it report an alarm?\u003c\/h4\u003e\n\u003cp\u003eIn under 0.2 seconds, because it interrupts the polling cycle.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is the address set?\u003c\/h4\u003e\n\u003cp\u003eAt the commissioning stage, with a seven segment DIL switch.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat do the LED colours mean?\u003c\/h4\u003e\n\u003cp\u003eRed shows the call point has been activated, and amber\/yellow indicates a short circuit. The fire control panel controls the LED.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it be fitted outdoors?\u003c\/h4\u003e\n\u003cp\u003eIt is intended for indoor applications and is designed to IP45.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57723712438645,"sku":"55100-908APO","price":51.65,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-55100-908apo-addressable-manual-call-point-with-isolator-front-view.jpg?v=1793788920"},{"product_id":"apollo-waterproof-manual-call-point-55200-003apo","title":"Apollo Conventional Waterproof Manual Call Point, Red, IP67 55200-003APO","description":"\u003cp\u003eThe Apollo 55200-003APO is a conventional waterproof manual call point, a device that lets a person raise a fire alarm by hand, for outdoor and wet positions. It suits installers on conventional fire detection systems. This red version has a resettable operating element, an IP rating of 67 and complies with EN54–11:2001.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMade for wet positions – IP rating 67 for the outdoor version\u003c\/li\u003e\n\u003cli\u003eQuick to reset – resettable operating element with an easy access, front reset mechanism\u003c\/li\u003e\n\u003cli\u003eSet to suit the panel – selectable 470Ω or 680 Ω alarm resistor\u003c\/li\u003e\n\u003cli\u003eEasy to see in alarm – 170° viewable LED indicator\u003c\/li\u003e\n\u003cli\u003eScrews stay put – captive screws on the outdoor variant\u003c\/li\u003e\n\u003cli\u003eMeets the call point standard – red version complies with EN54–11:2001\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: zone powered, 9-33V DC. Maximum alarm current with LED on 80mA at 24V DC.\u003c\/li\u003e\n\u003cli\u003eMounting: 110mm x 110mm x 74mm, 318g, IP rating 67.\u003c\/li\u003e\n\u003cli\u003eCabling: use IP rated cable glands on the 20 MM cable entries.\u003c\/li\u003e\n\u003cli\u003eCompatibility: conventional fire detection systems, with an alarm resistance of 470 or 680 Ohms.\u003c\/li\u003e\n\u003cli\u003eStandards: complies with EN54–11:2001 and EMC Directive 2004\/108\/EC.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eIs the 55200-003APO suitable for outdoor use?\u003c\/h4\u003e\n\u003cp\u003eYes. It is the waterproof version, with an outdoor IP rating of 67 and an operating temperature of -30°C to +70°C.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it use break glass?\u003c\/h4\u003e\n\u003cp\u003eNo. It has a resettable operating element, reset from the front with a reset key.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhich alarm resistor does it use?\u003c\/h4\u003e\n\u003cp\u003eThe resistor is selectable, 470 or 680 Ohms, so set it to suit the panel.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it have an LED?\u003c\/h4\u003e\n\u003cp\u003eYes. There is a red alarm LED, and the indicator is viewable over 170°.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat keeps water out at the cable entries?\u003c\/h4\u003e\n\u003cp\u003eUse IP rated cable glands, which are needed to keep the rating of the unit.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57723712504181,"sku":"55200-003APO","price":59.69,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-55200-003apo-waterproof-manual-call-point-front-view.jpg?v=1793788929"},{"product_id":"apollo-wireless-manual-call-point-rw1900-901apo","title":"Apollo REACH Wireless Manual Call Point, Resettable Element RW1900-901APO","description":"\u003cp\u003eThe Apollo RW1900-901APO is a wireless manual call point for REACH Wireless fire systems, used to raise an alarm by hand. It suits wall positions that are hard to reach with cable. It has a resettable plastic element, a supplied key and a battery life of 10 years in normal operation.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eRaises the alarm by hand – a wall-mounted device that initiates an alarm when activated\u003c\/li\u003e\n\u003cli\u003eReusable after use – resettable plastic element with a drop-down warning indicator\u003c\/li\u003e\n\u003cli\u003eQuick to put back in service – reset with the supplied key\u003c\/li\u003e\n\u003cli\u003eNo device cabling to run – battery powered with bi-directional wireless communication\u003c\/li\u003e\n\u003cli\u003eA fall-back on the radio link – dual channel redundancy\u003c\/li\u003e\n\u003cli\u003eLong battery service – 10 years in normal operation with good signal strength\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: 2x VARTA CR123A Lithium 3 V, 1250mAh typical.\u003c\/li\u003e\n\u003cli\u003eMounting: wall-mounted, 61 mm depth, 160 g including batteries.\u003c\/li\u003e\n\u003cli\u003eCompatibility: Apollo protocol is handled by the Loop-Interface, \u003ca href=\"\/products\/apollo-wireless-loop-interface-module-rw1700-030apo\"\u003eRW1700-030APO\u003c\/a\u003e.\u003c\/li\u003e\n\u003cli\u003eStandards: EN54-11 and EN54-25.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eIs a cover included?\u003c\/h4\u003e\n\u003cp\u003eNo. A transparent cover that protects against accidental operation is an accessory and is not included.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is it reset?\u003c\/h4\u003e\n\u003cp\u003eWith the key supplied. The same key opens the case.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow long do the batteries last?\u003c\/h4\u003e\n\u003cp\u003e10 years in normal operation with good signal strength and no dropped messages.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it wire to the fire panel?\u003c\/h4\u003e\n\u003cp\u003eNo. It links by radio to the Loop-Interface, RW1700-030APO, up to 100 m in open space.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow can someone see it has been activated?\u003c\/h4\u003e\n\u003cp\u003eThe element shows a drop-down warning indicator, and the LED shows red on for 1s in each 2s period.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57723720466805,"sku":"RW1900-901APO","price":147.94,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-rw1900-901apo-wireless-manual-call-point-front-view.png?v=1793789490"},{"product_id":"apollo-intelligent-manual-call-point-sa5900-905apo","title":"Apollo Intelligent Manual Call Point with Isolator, Blue SA5900-905APO","description":"\u003cp\u003eThe Apollo SA5900-905APO is a blue intelligent manual call point for addressable loops on XP95, Discovery or CoreProtocol systems. It raises an alarm when the resettable element is pressed. It suits sites that use a blue call point, and note that the EN 54 approvals are for the red version only.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUsed again after activation – resettable operating element\u003c\/li\u003e\n\u003cli\u003eQuick to reset – easy access, front reset mechanism with the supplied reset key\u003c\/li\u003e\n\u003cli\u003eEasy to read in an alarm – yellow and black indication bars and a solid red LED\u003c\/li\u003e\n\u003cli\u003eKeeps working through a wiring fault – a built-in short circuit isolator\u003c\/li\u003e\n\u003cli\u003eFaster first fix – cabling goes to a removable terminal block with the E-Z fit connector system\u003c\/li\u003e\n\u003cli\u003eTest before commissioning – continuity link for cable insulation testing\u003c\/li\u003e\n\u003cli\u003eFits the job – suitable for semi flush or surface mounting\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: loop powered, 17-35V DC. Max at 24V DC: quiescent 100µA, power up surge 1mA (1s typical), alarm 4mA with LED on.\u003c\/li\u003e\n\u003cli\u003eMounting: semi flush or surface, 90mm height x 90mm width x 63mm depth, 180g.\u003c\/li\u003e\n\u003cli\u003eCabling: all first-fix cabling goes to a removable terminal block, with a continuity link for insulation testing.\u003c\/li\u003e\n\u003cli\u003eCompatibility: CoreProtocol, Discovery \u0026amp; XP95 compatible Apollo control equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eIs the blue call point EN 54-11 certified?\u003c\/h4\u003e\n\u003cp\u003eNo. The EN 54-11, EN 54-17, CPR and LPCB approvals are for the red version only. Ask whoever designs the system whether a blue unit is acceptable for the job.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is it reset?\u003c\/h4\u003e\n\u003cp\u003eInsert the supplied reset key into the front facing LED and turn it clockwise until a positive click and reset occurs.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it have a short circuit isolator?\u003c\/h4\u003e\n\u003cp\u003eYes. It keeps working through a short circuit fault on the loop, and a solid yellow LED shows isolator operation.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is the address set?\u003c\/h4\u003e\n\u003cp\u003eBy a DIL switch, at the commissioning stage.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat do the LED colours mean?\u003c\/h4\u003e\n\u003cp\u003eSolid red shows alarm, flashing yellow shows a fault and flashing green shows the device being polled.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57723720925557,"sku":"SA5900-905APO","price":49.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-sa5900-905apo-intelligent-manual-call-point-front-view.jpg?v=1793789528"},{"product_id":"apollo-marine-manual-call-point-sa5900-928mar","title":"Apollo Intelligent Marine Manual Call Point with Isolator, Red SA5900-928MAR","description":"\u003cp\u003eThe Apollo SA5900-928MAR is an intelligent marine manual call point for indoor marine and offshore fire detection loops. It suits installers on XP95, Discovery or CoreProtocol systems. It has a resettable element and a built-in short-circuit isolator, and carries MED and ABS approvals alongside EN 54-11.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBuilt for marine jobs – intended for indoor marine and offshore applications\u003c\/li\u003e\n\u003cli\u003eMarine approvals – EN 54-11:2001, EN 54-17:2005, CPR, LPCB, MED and ABS\u003c\/li\u003e\n\u003cli\u003eUsed again after activation – resettable operating element with front reset and the supplied key\u003c\/li\u003e\n\u003cli\u003eKeeps the loop working – a built-in short-circuit isolator\u003c\/li\u003e\n\u003cli\u003eEasy to read in an alarm – yellow and black indication bars and a solid red LED\u003c\/li\u003e\n\u003cli\u003eFaster first fix – removable terminal block with the E-Z fit connector system\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: loop powered, 17-35 V dc. Max at 24V dc: quiescent 100 µA, power up surge 1 mA (1s typical), alarm 4 mA with LED on.\u003c\/li\u003e\n\u003cli\u003eMounting: semi flush or surface, 90 mm height x 90 mm width x 63 mm depth, 180 g.\u003c\/li\u003e\n\u003cli\u003eCabling: first-fix cabling goes to a removable terminal block, with a continuity link for insulation testing.\u003c\/li\u003e\n\u003cli\u003eCompatibility: XP95, Discovery and CoreProtocol compatible, depending on the fire control panel.\u003c\/li\u003e\n\u003cli\u003eStandards: EN 54-11:2001, EN 54-17:2005, CPR, LPCB, MED and ABS, with vibration and shock to IEC 60092-504:2016.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it be used outdoors on a vessel?\u003c\/h4\u003e\n\u003cp\u003eNo. It is intended for indoor marine and offshore applications.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhich marine approvals does it have?\u003c\/h4\u003e\n\u003cp\u003eMED and ABS, plus EN 54-11:2001, EN 54-17:2005, CPR and LPCB.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is it reset?\u003c\/h4\u003e\n\u003cp\u003eInsert the supplied reset key into the front facing LED and turn it clockwise until a positive click and reset occurs.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eAre spare keys and covers offered?\u003c\/h4\u003e\n\u003cp\u003eYes. Apollo offers the MCP Reset Key (Pack of 10), part 44251-176, and a Hinged cover, part 44251-189.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat do the LED colours mean?\u003c\/h4\u003e\n\u003cp\u003eSolid red shows alarm, flashing yellow shows a fault, flashing green shows polling and solid yellow shows isolator operation.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57723721482613,"sku":"SA5900-928MAR","price":56.7,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-sa5900-928mar-marine-manual-call-point-front-view.jpg?v=1793789536"},{"product_id":"apollo-wireless-manual-call-point-xpa-mc-14101-apo","title":"Apollo XPander Wireless Manual Call Point, Resettable XPA-MC-14101-APO","description":"\u003cp\u003eThe Apollo XPA-MC-14101-APO is an XPander wireless manual call point for raising a fire alarm by hand without running cable. It suits additions to XP95 or Discovery systems. It runs on six AA alkaline batteries, included, has a resettable operating element and reports an alarm in under one second.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNo device cabling to run – wireless operation\u003c\/li\u003e\n\u003cli\u003eUsed again after activation – a resettable operating element as standard\u003c\/li\u003e\n\u003cli\u003eQuick to report – fast response reports an alarm in under one second\u003c\/li\u003e\n\u003cli\u003eBatteries in the box – 6x AA alkaline included, typical working life of three to five years\u003c\/li\u003e\n\u003cli\u003eTested from the panel – remote test by a single bit in the communications protocol\u003c\/li\u003e\n\u003cli\u003eEasy to see once used – a red LED, lit when the call point is activated\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: two packs of three AA alkaline batteries, Panasonic LR6AD Powerline or Varta 4006 Industrial recommended.\u003c\/li\u003e\n\u003cli\u003eMounting: 90 mm width x 98 mm height x 72.5 mm depth, 350g with batteries installed, IP24.\u003c\/li\u003e\n\u003cli\u003eCompatibility: XP95 (native) and Discovery. Check the rest of the system before relying on any other protocol.\u003c\/li\u003e\n\u003cli\u003eStandards: EN 54-11, EN 54-25 and CPR.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eAre batteries included?\u003c\/h4\u003e\n\u003cp\u003eYes. It comes with 6x AA alkaline batteries, in two packs of three.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow long do the batteries last?\u003c\/h4\u003e\n\u003cp\u003eTypically three to five years. Panasonic LR6AD Powerline or Varta 4006 Industrial are the recommended cells to achieve five years.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is the address set?\u003c\/h4\u003e\n\u003cp\u003eWith an XPander XPERT card, at the commissioning stage.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it be used outdoors?\u003c\/h4\u003e\n\u003cp\u003eNo. It is Type A, for indoor use, with an IP24 rating.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it be tested without pressing it?\u003c\/h4\u003e\n\u003cp\u003eYes. It can be tested remotely from the panel, and it responds with a value of 64, the alarm value.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57723724693877,"sku":"XPA-MC-14101-APO","price":169.26,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-xpa-mc-14101-apo-wireless-manual-call-point-front-view.jpg?v=1793789652"},{"product_id":"apollo-outdoor-manual-call-point-55100-003apo","title":"Apollo Conventional Manual Call Point, Outdoor Red, IP67 55100-003APO","description":"\u003cp\u003eThe Apollo 55100-003APO is an outdoor manual call point for conventional fire detection systems. It lets anyone raise the alarm by hand from an outside wall or a wet area. Its IP rating is 67, and this red version complies with EN54-11. A resettable element replaces break glass.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNothing to replace after use – an easily resettable element rather than a break glass\u003c\/li\u003e\n\u003cli\u003eBuilt for wet locations – the outdoor version is rated IP 67\u003c\/li\u003e\n\u003cli\u003eReady to fix to the wall – supplied with a backbox for surface mounting\u003c\/li\u003e\n\u003cli\u003eFaster to wire – Plug and Play, with all cabling terminated at a terminal block\u003c\/li\u003e\n\u003cli\u003eHandles cold and heat outside – -25°C to +70°C operating range\u003c\/li\u003e\n\u003cli\u003eRecognised for fire use – the red version complies with EN54-11:2001\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: maximum supply voltage 30VDC. Switch rating 2A.\u003c\/li\u003e\n\u003cli\u003eMounting: surface, on the supplied backbox. 93mm x 97.5mm x 71mm, 350g.\u003c\/li\u003e\n\u003cli\u003eCabling: all installation cabling is terminated at the terminal block.\u003c\/li\u003e\n\u003cli\u003eCompatibility: for conventional fire detection systems. A 470Ω resistor sits in series with a normally open switch contact.\u003c\/li\u003e\n\u003cli\u003eStandards: complies with EN54-11:2001 as the red version.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat IP rating does this call point have?\u003c\/h4\u003e\n\u003cp\u003e67, on the outdoor version. The indoor versions in the range carry a lower rating.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is it reset after use?\u003c\/h4\u003e\n\u003cp\u003eWith the test key. Insert it into the bottom of the unit until it clicks, remove it, then push the front cover up until it clicks home.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it need glass replacing after activation?\u003c\/h4\u003e\n\u003cp\u003eNo. It has an easily resettable element rather than a break glass.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it work on an addressable system?\u003c\/h4\u003e\n\u003cp\u003eNo. It is designed for conventional fire detection systems, so it needs a conventional zone circuit to connect to.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eIs a back box included?\u003c\/h4\u003e\n\u003cp\u003eYes. It is supplied with a backbox for surface mounting.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat resistor is fitted?\u003c\/h4\u003e\n\u003cp\u003e470Ω, in series with a normally open switch contact. Check this suits your panel's zone circuit before fitting.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57725278159221,"sku":"55100-003APO","price":111.26,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-55100-003apo-outdoor-manual-call-point-front-view.jpg?v=1793816646"},{"product_id":"apollo-marine-manual-call-point-55100-021mar","title":"Apollo Conventional Marine Manual Call Point, Indoor Red 55100-021MAR","description":"\u003cp\u003eThe Apollo 55100-021MAR is a marine manual call point for conventional marine fire detection systems. It is the indoor red version, used to raise the alarm by hand inside a vessel or offshore space. It complies with EN54-11 and the Marine Equipment Directive 96\/98\/EC, and uses a resettable element.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMade for marine systems – designed for conventional marine fire detection systems\u003c\/li\u003e\n\u003cli\u003eNothing to replace after use – an easily resettable element rather than a break glass\u003c\/li\u003e\n\u003cli\u003eReady to fix – supplied with a backbox for surface mounting\u003c\/li\u003e\n\u003cli\u003eQuicker to wire – Plug and Play, with cabling terminated at a terminal block\u003c\/li\u003e\n\u003cli\u003eApproved for the job – complies with EN54-11:2001 and Marine Equipment Directive 96\/98\/EC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: maximum supply voltage 30VDC. Switch rating 2A.\u003c\/li\u003e\n\u003cli\u003eMounting: surface, on the supplied backbox. 93mm x 89mm x 59.5mm, 180g.\u003c\/li\u003e\n\u003cli\u003eCabling: all installation cabling is terminated at the terminal block.\u003c\/li\u003e\n\u003cli\u003eStandards: EN54-11:2001 and Marine Equipment Directive 96\/98\/EC.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eIs this call point for indoor or outdoor use?\u003c\/h4\u003e\n\u003cp\u003eIndoor. It is the Marine Indoor - Red version, with an IP rating of 24D.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhich marine approval does it hold?\u003c\/h4\u003e\n\u003cp\u003eIt complies with the Marine Equipment Directive 96\/98\/EC. Check this against the requirements of the vessel or classification body.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is it reset?\u003c\/h4\u003e\n\u003cp\u003eWith the test key. Insert it into the bottom of the unit until it clicks, remove it, then push the front cover up until it clicks home.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it need glass replacing?\u003c\/h4\u003e\n\u003cp\u003eNo. It has an easily resettable element rather than a break glass.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWill it work on a loop system?\u003c\/h4\u003e\n\u003cp\u003eNo. It is designed for conventional marine fire detection systems, not an addressable loop.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57725278650741,"sku":"55100-021MAR","price":22.91,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-55100-021mar-marine-manual-call-point-front-view.jpg?v=1793816656"},{"product_id":"apollo-intrinsically-safe-manual-call-point-55100-031apo","title":"Apollo Conventional IS Manual Call Point, Indoor Red 55100-031APO","description":"\u003cp\u003eThe Apollo 55100-031APO is an intrinsically safe manual call point for conventional I.S. fire detection systems. It is the indoor red version, for atmospheres in which explosive mixtures are or may be present. It complies with EN54-11 and the ATEX Directive 94\/9\/EC. System design rules apply.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMade for hazardous atmospheres – designed for use where explosive mixtures are or may be present\u003c\/li\u003e\n\u003cli\u003eWorks on the right system – designed for conventional intrinsically safe fire detection systems\u003c\/li\u003e\n\u003cli\u003eNothing to replace after use – an easily resettable element rather than a break glass\u003c\/li\u003e\n\u003cli\u003eReady to fix – supplied with a backbox for surface mounting\u003c\/li\u003e\n\u003cli\u003eRecognised standards – complies with EN54-11:2001 and ATEX Directive 94\/9\/EC\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: maximum supply voltage 30VDC. Switch rating 2A.\u003c\/li\u003e\n\u003cli\u003eMounting: surface, on the supplied backbox. 93mm x 89mm x 59.5mm, 180g.\u003c\/li\u003e\n\u003cli\u003eCabling: all installation cabling is terminated at the terminal block.\u003c\/li\u003e\n\u003cli\u003eCompatibility: for conventional intrinsically safe fire detection systems. Design considerations are covered in Apollo document PP1095.\u003c\/li\u003e\n\u003cli\u003eStandards: EN54-11:2001 and ATEX Directive 94\/9\/EC.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat does intrinsically safe mean?\u003c\/h4\u003e\n\u003cp\u003eIt limits electrical energy so a circuit cannot ignite an explosive atmosphere. This unit is designed for atmospheres in which explosive mixtures are or may be present.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it be used on a standard fire alarm circuit?\u003c\/h4\u003e\n\u003cp\u003eNo. It is designed for conventional intrinsically safe systems, and certain design considerations must be observed.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhere are the design rules?\u003c\/h4\u003e\n\u003cp\u003eIn Apollo document PP1095. Ask for it, and have the hazardous area design done by a specialist engineer.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is it reset?\u003c\/h4\u003e\n\u003cp\u003eWith the test key. Insert it into the bottom of the unit until it clicks, remove it, then push the front cover up until it clicks home.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eIs this version for indoor use?\u003c\/h4\u003e\n\u003cp\u003eYes. It is the IS Indoor - Red version, with an IP rating of 24D.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57725278912885,"sku":"55100-031APO","price":22.05,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-55100-031apo-intrinsically-safe-manual-call-point-front-view.jpg?v=1793816666"},{"product_id":"apollo-discovery-waterproof-manual-call-point-58100-951apo","title":"Apollo Discovery Waterproof Manual Call Point with Isolator, Red 58100-951APO","description":"\u003cp\u003eThe Apollo 58100-951APO is a red Discovery waterproof manual call point for addressable loops outdoors or in wet, dirty areas. It carries an IP67 rating and a built-in short circuit isolator. It operates only with control equipment using the Apollo Discovery protocol, and complies with EN54-11 and EN54-17.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBuilt for water and dirt – a waterproof IP67 rating\u003c\/li\u003e\n\u003cli\u003eKeeps working through a wiring fault – a built-in short circuit isolator\u003c\/li\u003e\n\u003cli\u003eA very fast alarm – activation interrupts the polling cycle\u003c\/li\u003e\n\u003cli\u003eUsed again after activation – an easily resettable element, not a break glass\u003c\/li\u003e\n\u003cli\u003eQuicker to wire – Plug and Play, with cabling terminated at a terminal block\u003c\/li\u003e\n\u003cli\u003eClear status – the LED shows red when activated, amber\/yellow for a short circuit\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: loop powered, 17–28V DC. Maximum at 24V: quiescent 100µA, power-up surge 1mA (1 second typical), alarm LED on 4mA.\u003c\/li\u003e\n\u003cli\u003eMounting: 93mm x 97.5mm x 71mm, 240g.\u003c\/li\u003e\n\u003cli\u003eCabling: cable gland size M20. All installation cabling is terminated at the terminal block.\u003c\/li\u003e\n\u003cli\u003eCompatibility: operates only with control equipment using the Apollo Discovery digital protocol.\u003c\/li\u003e\n\u003cli\u003eStandards: EN54-11:2001 and, on this isolated version, EN54-17:2005.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eWill it work on an XP95 panel?\u003c\/h4\u003e\n\u003cp\u003ePlan on Discovery only. It operates only with control equipment using the Apollo Discovery digital protocol, so check the panel first.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it have an isolator?\u003c\/h4\u003e\n\u003cp\u003eYes. This is the red, isolated version, and the isolator keeps it working during a short circuit fault on the loop.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is it reset?\u003c\/h4\u003e\n\u003cp\u003eWith the test key. Insert it into the bottom of the unit until it clicks, remove it, then push the front cover up until it clicks home.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is the address set?\u003c\/h4\u003e\n\u003cp\u003eAt the commissioning stage, on a seven-segment DIL switch.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhich standards does it meet?\u003c\/h4\u003e\n\u003cp\u003eEN54-11:2001 and EN54-17:2005, the second applying to the isolated version.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57725279502709,"sku":"58100-951APO","price":224.29,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-58100-951apo-discovery-waterproof-manual-call-point-front-view.png?v=1793816699"},{"product_id":"apollo-waterproof-addressable-manual-call-point-58200-950apo","title":"Apollo Waterproof Addressable Manual Call Point, Red 58200-950APO","description":"\u003cp\u003eThe Apollo 58200-950APO is a red waterproof addressable manual call point for outdoor loops or wet areas. It runs on XP95, Discovery and CoreProtocol systems, and is IP56 rated with an IP67 rated electronics enclosure. This version has no isolator, and it is EN 54-11 certified with a resettable element.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBuilt for wet locations – IP56 rated, with an IP67 rated electronics enclosure\u003c\/li\u003e\n\u003cli\u003eA very fast alarm – when activated it interrupts the polling cycle\u003c\/li\u003e\n\u003cli\u003eUsed again after activation – resettable operating element\u003c\/li\u003e\n\u003cli\u003eSimple to put right – easy access, front reset mechanism and an ergonomic reset key\u003c\/li\u003e\n\u003cli\u003eEasier second fix – captive screws for easy installation\u003c\/li\u003e\n\u003cli\u003eWorks across Apollo protocols – XP95, Discovery and CoreProtocol compatible\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: loop powered, 17-28V dc. Max at 24V dc: quiescent 100µA, power up surge 1mA (1s typical), alarm 4mA with LED on.\u003c\/li\u003e\n\u003cli\u003eMounting: 114mm height x 114mm width x 74mm depth, 325g.\u003c\/li\u003e\n\u003cli\u003eCabling: 20 mm cable entries. Cable entry from the bottom of the unit is recommended, using correctly IP rated glands.\u003c\/li\u003e\n\u003cli\u003eCompatibility: XP95, Discovery and CoreProtocol. On CoreProtocol it behaves as a Discovery device. Fire control panel dependant.\u003c\/li\u003e\n\u003cli\u003eStandards: EN 54-11 certified. EN 54-17 applies only to the isolated 58200-951.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes this version have a short circuit isolator?\u003c\/h4\u003e\n\u003cp\u003eNo. This is the red version without one. The isolated red version is part 58200-951.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow waterproof is it?\u003c\/h4\u003e\n\u003cp\u003eIt is IP56 rated, with an IP67 rated electronics enclosure. Unused entries and glands must be fully tightened and sealed to keep that rating.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is the address set?\u003c\/h4\u003e\n\u003cp\u003eAt the commissioning stage, on a seven-segment DIL switch.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is it reset?\u003c\/h4\u003e\n\u003cp\u003eInsert the reset key into the front facing LED and turn it clockwise until a positive click and reset occurs.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhich protocols does it work with?\u003c\/h4\u003e\n\u003cp\u003eXP95, Discovery and CoreProtocol, depending on the fire control panel. On CoreProtocol it behaves as a Discovery device.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57725279732085,"sku":"58200-950APO","price":106.55,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-58200-950apo-waterproof-addressable-manual-call-point-front-view.jpg?v=1793816708"},{"product_id":"apollo-marine-waterproof-manual-call-point-58200-975mar","title":"Apollo Marine Waterproof Manual Call Point Red 58200-975MAR","description":"\u003cp\u003eThe Apollo 58200-975MAR is a red marine waterproof manual call point for addressable loops in wet or exposed locations. It is designed to IP67 and certified to EN 54-11 and the Marine Equipment Directive 2014\/90\/EU. It works with XP95, Discovery and CoreProtocol, with a resettable element.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBuilt for wet locations – designed to IP67\u003c\/li\u003e\n\u003cli\u003eMade for marine use – Marine Equipment Directive 2014\/90\/EU certified\u003c\/li\u003e\n\u003cli\u003eA very fast alarm – activation interrupts the polling cycle\u003c\/li\u003e\n\u003cli\u003eUsed again after activation – resettable operating element\u003c\/li\u003e\n\u003cli\u003eSimple to put right – easy access, front reset mechanism and an ergonomic reset key\u003c\/li\u003e\n\u003cli\u003eEasier second fix – captive screws for easy installation\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: loop-powered, 17-28 V dc. Max at 24 V dc: quiescent 100 µA, power up surge 1 mA (1s typical), alarm 4 mA with LED on.\u003c\/li\u003e\n\u003cli\u003eCabling: cable entry from the bottom of the unit is recommended, using correctly IP rated glands.\u003c\/li\u003e\n\u003cli\u003eCompatibility: XP95, Discovery and CoreProtocol. On CoreProtocol it behaves as a Discovery device. Fire control panel dependant.\u003c\/li\u003e\n\u003cli\u003eStandards: EN 54-11, CPR, MED, LR, ABS and SBSC.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes this version have a short circuit isolator?\u003c\/h4\u003e\n\u003cp\u003eNo. The version with an isolator is part 58200-976MAR.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhich protocols does it work with?\u003c\/h4\u003e\n\u003cp\u003eXP95, Discovery and CoreProtocol, depending on the fire control panel. On CoreProtocol it behaves as a Discovery device.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhich marine approvals does it have?\u003c\/h4\u003e\n\u003cp\u003eIt holds MED, LR, ABS and SBSC approvals, alongside EN 54-11 and CPR. Check these against the vessel or classification society requirement.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is it reset?\u003c\/h4\u003e\n\u003cp\u003eInsert the reset key into the front facing LED and turn it clockwise until a positive click and reset occurs.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is the address set?\u003c\/h4\u003e\n\u003cp\u003eAt the commissioning stage, on a seven-segment DIL switch.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57725279928693,"sku":"58200-975MAR","price":167.93,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-58200-975mar-marine-waterproof-manual-call-point-front-view.jpg?v=1793816718"},{"product_id":"apollo-marine-waterproof-manual-call-point-58200-976mar","title":"Apollo Marine Waterproof Manual Call Point with Isolator, Red 58200-976MAR","description":"\u003cp\u003eThe Apollo 58200-976MAR is a red marine waterproof manual call point with a short circuit isolator for addressable loops in wet or exposed locations. It is designed to IP67 and certified to EN 54-11 and the Marine Equipment Directive 2014\/90\/EU. It works with XP95, Discovery and CoreProtocol, with a resettable element.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBuilt for wet locations – designed to IP67\u003c\/li\u003e\n\u003cli\u003eMade for marine use – Marine Equipment Directive 2014\/90\/EU certified\u003c\/li\u003e\n\u003cli\u003eA very fast alarm – activation interrupts the polling cycle\u003c\/li\u003e\n\u003cli\u003eUsed again after activation – resettable operating element\u003c\/li\u003e\n\u003cli\u003eSimple to put right – easy access, front reset mechanism and an ergonomic reset key\u003c\/li\u003e\n\u003cli\u003eKeeps working through a wiring fault – a built-in short circuit isolator, shown by a yellow LED\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: loop-powered, 17-28 V dc. Max at 24 V dc: quiescent 100 µA, power up surge 1 mA (1s typical), alarm 4 mA with LED on.\u003c\/li\u003e\n\u003cli\u003eCabling: cable entry from the bottom of the unit is recommended, using correctly IP rated glands.\u003c\/li\u003e\n\u003cli\u003eCompatibility: XP95, Discovery and CoreProtocol. On CoreProtocol it behaves as a Discovery device. Fire control panel dependant.\u003c\/li\u003e\n\u003cli\u003eStandards: EN 54-11, CPR, MED, LR, ABS and SBSC.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat does the isolator do?\u003c\/h4\u003e\n\u003cp\u003eIt keeps this call point operating during a short circuit fault on the loop. A yellow LED shows when it has operated.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhich protocols does it work with?\u003c\/h4\u003e\n\u003cp\u003eXP95, Discovery and CoreProtocol, depending on the fire control panel. On CoreProtocol it behaves as a Discovery device.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhich marine approvals does it have?\u003c\/h4\u003e\n\u003cp\u003eIt holds MED, LR, ABS and SBSC approvals, alongside EN 54-11 and CPR. Check these against the vessel or classification society requirement.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is it reset?\u003c\/h4\u003e\n\u003cp\u003eInsert the reset key into the front facing LED and turn it clockwise until a positive click and reset occurs.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is the address set?\u003c\/h4\u003e\n\u003cp\u003eAt the commissioning stage, on a seven-segment DIL switch.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat load does it add to an isolated section?\u003c\/h4\u003e\n\u003cp\u003eAn Equivalent Detector Load of 1. The maximum load for a node is an EDL of 20.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57725280190837,"sku":"58200-976MAR","price":163.83,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-58200-976mar-marine-waterproof-manual-call-point-front-view.jpg?v=1793816733"},{"product_id":"apollo-dual-switch-manual-call-point-sa5900-011apo","title":"Apollo Dual Switch Manual Call Point, Green SA5900-011APO","description":"\u003cp\u003eThe Apollo SA5900-011APO is a green dual switch manual call point for switching other equipment from one press. It suits doors, barriers and control circuits needing normally open or normally closed contacts. It provides volt free double pole change-over contacts rated at 33V DC and 2A, with a resettable element.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOne press, several circuits – multiple switching from a single activation point\u003c\/li\u003e\n\u003cli\u003eWire it either way – volt free double pole change-over contacts, normally open or normally closed\u003c\/li\u003e\n\u003cli\u003eUsed again after activation – resettable operating element\u003c\/li\u003e\n\u003cli\u003eQuick to put right – easy access, front reset mechanism with the supplied reset key\u003c\/li\u003e\n\u003cli\u003eClear at a glance – yellow and black indication bars show it has been activated\u003c\/li\u003e\n\u003cli\u003eFits the job – suitable for semi flush or surface mounting\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: contact rating 33V DC at 2A. Supply range 0-33V DC.\u003c\/li\u003e\n\u003cli\u003eMounting: semi flush or surface. 90mm height x 90mm width x 63mm depth, 180g.\u003c\/li\u003e\n\u003cli\u003eCabling: volt free double pole change-over contacts, so the switched circuit brings its own supply.\u003c\/li\u003e\n\u003cli\u003eCompatibility: use it within the 33V DC and 2A contact rating. Use a relay for anything larger.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat are the contacts rated at?\u003c\/h4\u003e\n\u003cp\u003e33V DC at 2A. Keep the switched load within that figure.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it need a power supply of its own?\u003c\/h4\u003e\n\u003cp\u003eThe contacts are volt free, so the circuit wired through them provides the voltage.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it switch normally open and normally closed circuits?\u003c\/h4\u003e\n\u003cp\u003eYes. The double pole change-over contacts suit normally open or normally closed multiple switching.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is it reset?\u003c\/h4\u003e\n\u003cp\u003eFrom the front, using the supplied reset key.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eIs a cover included?\u003c\/h4\u003e\n\u003cp\u003eThe transparent hinged cover is an option, so it does not come as standard.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it go outside?\u003c\/h4\u003e\n\u003cp\u003eCheck the location first. It is rated IP44, so a sheltered position is the safer choice.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57725806182773,"sku":"SA5900-011APO","price":18.22,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-sa5900-011apo-dual-switch-manual-call-point-front-view.jpg?v=1793818719"},{"product_id":"apollo-intelligent-manual-call-point-sa5900-904apo","title":"Apollo Intelligent Manual Call Point with Isolator, Yellow SA5900-904APO","description":"\u003cp\u003eThe Apollo SA5900-904APO is a yellow intelligent manual call point for addressable loops on XP95, Discovery or CoreProtocol systems. It raises an alarm when the resettable element is pressed. It suits sites that use a yellow call point, and note that the EN 54 approvals are for the red version only.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUsed again after activation – resettable operating element\u003c\/li\u003e\n\u003cli\u003eQuick to reset – easy access, front reset mechanism with the supplied reset key\u003c\/li\u003e\n\u003cli\u003eEasy to read in an alarm – yellow and black indication bars and a solid red LED\u003c\/li\u003e\n\u003cli\u003eKeeps working through a wiring fault – a built-in short circuit isolator\u003c\/li\u003e\n\u003cli\u003eFaster first fix – cabling goes to a removable terminal block with the E-Z fit connector system\u003c\/li\u003e\n\u003cli\u003eTest before commissioning – continuity link for cable insulation testing\u003c\/li\u003e\n\u003cli\u003eFits the job – suitable for semi flush or surface mounting\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: loop powered, 17-35V DC. Max at 24V DC: quiescent 100µA, power up surge 1mA (1s typical), alarm 4mA with LED on.\u003c\/li\u003e\n\u003cli\u003eMounting: semi flush or surface, 90mm height x 90mm width x 63mm depth, 180g.\u003c\/li\u003e\n\u003cli\u003eCabling: all first-fix cabling goes to a removable terminal block, with a continuity link for insulation testing.\u003c\/li\u003e\n\u003cli\u003eCompatibility: CoreProtocol, Discovery \u0026amp; XP95 compatible Apollo control equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eIs the yellow call point EN 54-11 certified?\u003c\/h4\u003e\n\u003cp\u003eNo. The EN 54-11, EN 54-17, CPR and LPCB approvals are for the red version only. Ask whoever designs the system whether a yellow unit is acceptable for the job.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is it reset?\u003c\/h4\u003e\n\u003cp\u003eInsert the supplied reset key into the front facing LED and turn it clockwise until a positive click and reset occurs.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it have a short circuit isolator?\u003c\/h4\u003e\n\u003cp\u003eYes. It keeps working through a short circuit fault on the loop, and a solid yellow LED shows isolator operation.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is the address set?\u003c\/h4\u003e\n\u003cp\u003eBy a DIL switch, at the commissioning stage.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat do the LED colours mean?\u003c\/h4\u003e\n\u003cp\u003eSolid red shows alarm, flashing yellow shows a fault and flashing green shows the device being polled.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57725808148853,"sku":"SA5900-904APO","price":50.33,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-sa5900-904apo-intelligent-manual-call-point-front-view.jpg?v=1793818729"},{"product_id":"apollo-manual-call-point-55100-002apo","title":"Apollo Conventional Manual Call Point, Indoor Yellow, Resettable 55100-002APO","description":"\u003cp\u003eThe Apollo 55100-002APO is an indoor yellow manual call point for conventional fire detection systems. It lets a person trigger a signal by hand on a zone circuit, using an easily resettable element rather than a break glass. It comes with a backbox for surface mounting, and its IP rating is 24D.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNothing to replace after use – an easily resettable element rather than a break glass\u003c\/li\u003e\n\u003cli\u003eReady to fix to the wall – supplied with a backbox for surface mounting\u003c\/li\u003e\n\u003cli\u003eFaster to wire – Plug and Play, with all installation cabling terminated at a terminal block\u003c\/li\u003e\n\u003cli\u003eEasy reset – a test key releases it, then the front cover pushes up until it clicks home\u003c\/li\u003e\n\u003cli\u003eSimple circuit – a 470Ω resistor in series with a normally open switch contact\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: maximum supply voltage 30VDC. Switch rating 2A.\u003c\/li\u003e\n\u003cli\u003eMounting: surface, on the supplied backbox. 93mm x 89mm x 59.5mm, 180g.\u003c\/li\u003e\n\u003cli\u003eCabling: all installation cabling is terminated at the terminal block.\u003c\/li\u003e\n\u003cli\u003eCompatibility: for conventional fire detection systems. Check the 470Ω value suits the panel's zone circuit.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat is a yellow call point for?\u003c\/h4\u003e\n\u003cp\u003eIt is commonly used to manually control extinguishant release, kept apart from red fire alarm call points. The system designer decides what it does, and the EN54-11 approval belongs to the red version, so use red where the specification asks for it.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is it reset after use?\u003c\/h4\u003e\n\u003cp\u003eWith the test key. Insert it into the bottom of the unit until it clicks, remove it, then push the front cover up until it clicks home.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it need glass replacing after activation?\u003c\/h4\u003e\n\u003cp\u003eNo. It has an easily resettable element rather than a break glass.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it work on an addressable system?\u003c\/h4\u003e\n\u003cp\u003eNo. It is designed for conventional fire detection systems, so it needs a conventional zone circuit.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eIs a back box included?\u003c\/h4\u003e\n\u003cp\u003eYes. It is supplied with a backbox for surface mounting.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it be fitted outside?\u003c\/h4\u003e\n\u003cp\u003eNo. This is the indoor version, rated IP 24D. The outdoor versions in the range carry a separate part number.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57727894815093,"sku":"55100-002APO","price":26.72,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-55100-002apo-manual-call-point-angled-view.png?v=1793827529"},{"product_id":"apollo-marine-waterproof-manual-call-point-58100-976mar","title":"Apollo Discovery Marine Waterproof Manual Call Point with Isolator, IP67 58100-976MAR","description":"\u003cp\u003eThe Apollo 58100-976MAR is a Discovery marine waterproof manual call point with isolator, for raising a fire alarm by hand in marine and offshore environments. It is designed to IP67, has a resettable operating element and is XP95, Discovery and CoreProtocol compatible. It is certified to EN 54-11 and EN 54-17.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBuilt for wet locations – designed to IP67\u003c\/li\u003e\n\u003cli\u003eNothing to replace after use – a resettable operating element\u003c\/li\u003e\n\u003cli\u003eQuick to put right – easy access, front reset mechanism\u003c\/li\u003e\n\u003cli\u003eLimits a loop fault – isolated version, with an amber\/yellow LED showing a short-circuit either side\u003c\/li\u003e\n\u003cli\u003eFast signal to the panel – interrupts the normal protocol to give a fast response\u003c\/li\u003e\n\u003cli\u003eMarine approvals – MED, DNV-GL, ABS, CCS and VNIIPO\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: two-wire supply, polarity sensitive, 17 - 28 V dc. Alarm current 4 mA with the LED lit.\u003c\/li\u003e\n\u003cli\u003eMounting: supplied with a back box for surface mounting as standard.\u003c\/li\u003e\n\u003cli\u003eCabling: terminal block L1 -ve\/L2 +ve, with clip-on terminal blocks and a connector for continuity testing before commissioning.\u003c\/li\u003e\n\u003cli\u003eCompatibility: XP95, Discovery and CoreProtocol compatible. Address set by a seven-segment DIL switch.\u003c\/li\u003e\n\u003cli\u003eStandards: EN 54-11, EN 54-17 (isolated version), MED, DNV-GL, ABS, CCS and VNIIPO.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes a hinged cover affect the approval?\u003c\/h4\u003e\n\u003cp\u003eYes. This call point does not conform to EN 54-11 when the hinged lid and locking tag are fitted, so check your specification first.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is the address set?\u003c\/h4\u003e\n\u003cp\u003eAt commissioning, by means of a seven-segment DIL switch. The addressing is front facing, so it is easy to reach.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it be tested from the panel?\u003c\/h4\u003e\n\u003cp\u003eYes. It responds with a value of 64, and the panel should recognise this as a test signal and not raise a general alarm.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat does the yellow LED show?\u003c\/h4\u003e\n\u003cp\u003eA short-circuit on the loop wiring either side of the call point. The red LED shows it has been activated.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhich protocols does the 58100-976MAR work with?\u003c\/h4\u003e\n\u003cp\u003eXP95, Discovery and CoreProtocol. Check your panel uses one of these before ordering.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat temperature range does it cover?\u003c\/h4\u003e\n\u003cp\u003e-20°C to +60°C in operation, so check this against the location on the vessel or platform.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57727896027509,"sku":"58100-976MAR","price":268.69,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-58100-976mar-marine-waterproof-manual-call-point-angled-view.jpg?v=1793827579"},{"product_id":"apollo-intelligent-manual-call-point-sa5900-903apo","title":"Apollo Intelligent Manual Call Point with Isolator, White SA5900-903APO","description":"\u003cp\u003eThe Apollo SA5900-903APO is a white intelligent manual call point for addressable loops on XP95, Discovery or CoreProtocol systems. It raises an alarm when the resettable element is pressed. It suits sites that use a white call point, and note that the EN 54 approvals are for the red version only.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUsed again after activation – resettable operating element\u003c\/li\u003e\n\u003cli\u003eQuick to reset – easy access, front reset mechanism with the supplied reset key\u003c\/li\u003e\n\u003cli\u003eEasy to read in an alarm – yellow and black indication bars and a solid red LED\u003c\/li\u003e\n\u003cli\u003eKeeps working through a wiring fault – a built-in short circuit isolator\u003c\/li\u003e\n\u003cli\u003eFaster first fix – cabling goes to a removable terminal block with the E-Z fit connector system\u003c\/li\u003e\n\u003cli\u003eTest before commissioning – continuity link for cable insulation testing\u003c\/li\u003e\n\u003cli\u003eFits the job – suitable for semi flush or surface mounting\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: loop powered, 17-35V DC. Max at 24V DC: quiescent 100µA, power up surge 1mA (1s typical), alarm 4mA with LED on.\u003c\/li\u003e\n\u003cli\u003eMounting: semi flush or surface, 90mm height x 90mm width x 63mm depth, 180g.\u003c\/li\u003e\n\u003cli\u003eCabling: all first-fix cabling goes to a removable terminal block, with a continuity link for insulation testing.\u003c\/li\u003e\n\u003cli\u003eCompatibility: CoreProtocol, Discovery \u0026amp; XP95 compatible Apollo control equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eIs the white call point EN 54-11 certified?\u003c\/h4\u003e\n\u003cp\u003eNo. The EN 54-11, EN 54-17, CPR and LPCB approvals are for the red version only. Ask whoever designs the system whether a white unit is acceptable for the job.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is it reset?\u003c\/h4\u003e\n\u003cp\u003eInsert the supplied reset key into the front facing LED and turn it clockwise until a positive click and reset occurs.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it have a short circuit isolator?\u003c\/h4\u003e\n\u003cp\u003eYes. It keeps working through a short circuit fault on the loop, and a solid yellow LED shows isolator operation.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is the address set?\u003c\/h4\u003e\n\u003cp\u003eBy a DIL switch, at the commissioning stage.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat do the LED colours mean?\u003c\/h4\u003e\n\u003cp\u003eSolid red shows alarm, flashing yellow shows a fault and flashing green shows the device being polled.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57727913591157,"sku":"SA5900-903APO","price":49.98,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-sa5900-903apo-intelligent-manual-call-point-front-view.jpg?v=1793828339"},{"product_id":"apollo-intelligent-manual-call-point-sa5900-906apo","title":"Apollo Intelligent Manual Call Point with Isolator, Green SA5900-906APO","description":"\u003cp\u003eThe Apollo SA5900-906APO is a green intelligent manual call point for addressable loops on XP95, Discovery or CoreProtocol systems. It raises an alarm when the resettable element is pressed. It suits sites that use a green call point, and note that the EN 54 approvals are for the red version only.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eUsed again after activation – resettable operating element\u003c\/li\u003e\n\u003cli\u003eQuick to reset – easy access, front reset mechanism with the supplied reset key\u003c\/li\u003e\n\u003cli\u003eEasy to read in an alarm – yellow and black indication bars and a solid red LED\u003c\/li\u003e\n\u003cli\u003eKeeps working through a wiring fault – a built-in short circuit isolator\u003c\/li\u003e\n\u003cli\u003eFaster first fix – cabling goes to a removable terminal block with the E-Z fit connector system\u003c\/li\u003e\n\u003cli\u003eTest before commissioning – continuity link for cable insulation testing\u003c\/li\u003e\n\u003cli\u003eFits the job – suitable for semi flush or surface mounting\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: loop powered, 17-35V DC. Max at 24V DC: quiescent 100µA, power up surge 1mA (1s typical), alarm 4mA with LED on.\u003c\/li\u003e\n\u003cli\u003eMounting: semi flush or surface, 90mm height x 90mm width x 63mm depth, 180g.\u003c\/li\u003e\n\u003cli\u003eCabling: all first-fix cabling goes to a removable terminal block, with a continuity link for insulation testing.\u003c\/li\u003e\n\u003cli\u003eCompatibility: CoreProtocol, Discovery \u0026amp; XP95 compatible Apollo control equipment.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eIs the green call point EN 54-11 certified?\u003c\/h4\u003e\n\u003cp\u003eNo. The EN 54-11, EN 54-17, CPR and LPCB approvals are for the red version only. Ask whoever designs the system whether a green unit is acceptable for the job.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is it reset?\u003c\/h4\u003e\n\u003cp\u003eInsert the supplied reset key into the front facing LED and turn it clockwise until a positive click and reset occurs.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it have a short circuit isolator?\u003c\/h4\u003e\n\u003cp\u003eYes. It keeps working through a short circuit fault on the loop, and a solid yellow LED shows isolator operation.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is the address set?\u003c\/h4\u003e\n\u003cp\u003eBy a DIL switch, at the commissioning stage.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat do the LED colours mean?\u003c\/h4\u003e\n\u003cp\u003eSolid red shows alarm, flashing yellow shows a fault and flashing green shows the device being polled.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57727913623925,"sku":"SA5900-906APO","price":50.33,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-sa5900-906apo-intelligent-manual-call-point-front-view.jpg?v=1793828349"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/collections\/apollo_sa5900-908apo.png?v=1747058503","url":"https:\/\/wmestore.co.uk\/collections\/apollo-call-points.oembed?page=2","provider":"WME","version":"1.0","type":"link"}