{"title":"Apollo Smoke Detectors","description":"\u003cp\u003eAn Apollo smoke detector is a fire alarm detector head that reports to a control panel rather than sounding on its own. This collection covers Apollo optical smoke detectors across its ranges: XP95 and Discovery addressable heads, Soteria and Soteria Dimension detectors, AlarmSense two-wire, REACH Wireless and an XPander head, for addressable, two-wire and wireless systems, with EN54-7 cited on models such as the Discovery 58000-600APO.\u003c\/p\u003e","products":[{"product_id":"alarmsense-optical-smoke-detector-2-wire-en54-7-9-33-v-dc-100-42-mm-55000-390apo","title":"AlarmSense Optical Smoke Detector, 2-wire, EN54-7, 9-33 V DC, 100×42 mm 55000-390APO","description":"\u003cp\u003e\u003cstrong\u003eApollo 55000-390APO AlarmSense Optical Smoke Detector\u003c\/strong\u003e — a compact, EN54‑7 certified optical (photoelectric) detector designed for residential and small-to-medium commercial installations. Ideal for bedrooms, escape routes, care homes, HMOs and similar areas where early detection of smouldering fires is required. The detector fits a compatible AlarmSense two‑wire base and provides 360° LED status indication.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eDetection principle:\u003c\/strong\u003e Optical \/ photoelectric (light‑scatter, chevron chamber) — effective for slow‑burning and smouldering fires.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e EN54‑7 certified (third‑party).\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSupply voltage:\u003c\/strong\u003e 9–33 V DC; polarity‑insensitive 2‑wire monitored connection.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eLow standby draw:\u003c\/strong\u003e Quiescent current ≈ 50 µA @ 15 V.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eCompact design:\u003c\/strong\u003e ≈100 mm diameter × 42 mm depth (detector only); white polycarbonate housing with 360° LED.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e 10 years (manufacturer stated).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eUse cases:\u003c\/strong\u003e Suitable for domestic, education and light commercial sites where AlarmSense two‑wire detection is used. Requires compatible AlarmSense base and installer configuration according to the system panel manufacturer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety \u0026amp; compliance notes:\u003c\/strong\u003e EN54‑7 certification is stated by the manufacturer. Installation should be performed by a competent engineer in accordance with BS 5839‑1 (or the relevant national standard) and the product installation manual.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRecommendation:\u003c\/strong\u003e Refer to the official Apollo datasheet\/installation manual for precise alarm current curves, supply‑interrupt tolerance and base compatibility before specifying or installing.\u003c\/p\u003e","brand":"Apollo Fire","offers":[{"title":"-","offer_id":56594922307957,"sku":"55000-390APO","price":18.38,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/ITM002852_1.png?v=1768252476"},{"product_id":"discovery-optical-smoke-detector-addressable-en54-7-17-28-v-58000-600apo","title":"Discovery Optical Smoke Detector, Addressable, EN54-7, 17-28 V, 58000-600APO","description":"\u003cp\u003e\u003cstrong\u003eApollo Discovery 58000-600APO — Optical (photo‑electric) addressable smoke detector.\u003c\/strong\u003e Uses a forward light‑scatter chamber to detect slow‑burning and smouldering fires while reducing false alarms. Designed for commercial and residential applications including hospitals, hotels, offices, care homes and escape routes.\u003c\/p\u003e\n\u003cul\u003e\n  \u003cli\u003ePhoto‑electric (light‑scatter) sensing chamber with drift compensation and five selectable response modes for false‑alarm management.\u003c\/li\u003e\n  \u003cli\u003eDiscovery analogue addressable protocol — reports analogue values (nominal 23, alarm threshold 55); sampling once per second.\u003c\/li\u003e\n  \u003cli\u003eRemote LED\/test connections (+R \/ −R) and remote test support.\u003c\/li\u003e\n  \u003cli\u003eWide supply and operating range: 17–28 V DC; low quiescent current (~440 μA at 24 V DC); alarm current ~3–3.4 mA (LED on).\u003c\/li\u003e\n  \u003cli\u003eDurable white polycarbonate housing with stainless steel terminals; compact diameter 100 mm, low profile.\u003c\/li\u003e\n  \u003cli\u003eApproved to EN54‑7 and covered by multiple regional approvals (LPCB, VdS, CPR). Manufacturer warranty: 10 years.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSafety \u0026amp; installation:\u003c\/strong\u003e Installation, commissioning and maintenance should be carried out by a qualified fire‑alarm engineer in accordance with local regulations and the manufacturer’s datasheet\/installation instructions. Ensure compatibility with your Discovery protocol fire panel. \u003c\/p\u003e","brand":"Apollo Fire","offers":[{"title":"-","offer_id":56594972049781,"sku":"58000-600APO","price":45.97,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/ITM002895_1.png?v=1768253765"},{"product_id":"apollo-fire-smoke-detector-fl5100-660apo","title":"Apollo Fire FL5100-660APO smoke detector, Black","description":"\u003cp\u003e\u003cstrong\u003eApollo Fire FL5100-660APO is a smoke detector.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe innovative design of the Soteria Dimension Optical Detector differs from standard fire detectors, with its chamberless and flush mounted design.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLow profile design\u003c\/li\u003e\n\u003cli\u003eIntegrated switchable isolator\u003c\/li\u003e\n\u003cli\u003eTri-coloured LED\u003c\/li\u003e\n\u003cli\u003eDIL switch addressing\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57534953718133,"sku":"FL5100-660APO","price":211.58,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/FL5100-660APO.jpg?v=1788048203"},{"product_id":"apollo-fire-optical-smoke-detector-xpa-cb-12034-apo","title":"Apollo Fire XPA-CB-12034-APO optical smoke detector, White","description":"\u003cp\u003e\u003cstrong\u003eApollo Fire XPA-CB-12034-APO is an optical smoke detector from the Xpander range.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eXPander optical detectors are recommended for use as general-purpose smoke detectors for early warning of fire in most installations. The detector is calibrated so that XPander is highly reliable in detecting fires but has enhanced immunity to false alarms. The optical design operates on the well-established light scatter principle, allowing it to respond to a wide spectrum of fires.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlgorithms for transient alarm rejection\u003c\/li\u003e\n\u003cli\u003eAutomatic Drift-Compensation with DirtAlert warning\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57543238648181,"sku":"XPA-CB-12034-APO","price":197.13,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/XPA-CB-12034-APO.jpg?v=1788393337"},{"product_id":"apollo-fire-optical-smoke-detector-rw1000-660apo","title":"Apollo Fire RW1000-660APO optical smoke detector, Black","description":"\u003cp\u003e\u003cstrong\u003ePlease note: this is a non-returnable item (excluding faulty goods)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApollo Fire RW1000-660APO is an optical smoke detector from the REACH Wireless range.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe RW1000-660APO is a wireless addressable optical smoke detector that utilises dual-optical smoke detection technology for improved performance; maintaining the highest levels of false-alarm rejection.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTwin alarm, bi-colour LEDs for 360° visibility\u003c\/li\u003e\n\u003cli\u003eAdvanced dual-optical chamber design\u003c\/li\u003e\n\u003cli\u003eAdvanced drift compensation\u003c\/li\u003e\n\u003cli\u003eBi-directional wireless communication\u003c\/li\u003e\n\u003cli\u003eDual-channel redundancy\u003c\/li\u003e\n\u003cli\u003eTen-year battery life\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57546252222837,"sku":"RW1000-660APO","price":178.13,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/RW1000-660APO.jpg?v=1788470359"},{"product_id":"apollo-fire-optical-smoke-detector-fl6100-600apo","title":"Apollo Fire FL6100-600APO optical smoke detector","description":"\u003cp\u003e\u003cstrong\u003eApollo Fire FL6100-600APO is an optical smoke detector from the Soteria range.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Soteria Dimension Specialist Optical Detector is independently certified to DHF TS001 for anti-ligature use in specialist areas.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUtilises digital CoreProtocol communications\u003c\/li\u003e\n\u003cli\u003eCompatible with Discovery and XP95 systems\u003c\/li\u003e\n\u003cli\u003eIntegrated switchable isolator as standard\u003c\/li\u003e\n\u003cli\u003e8-way DIL switch addressing\u003c\/li\u003e\n\u003cli\u003eDrift compensation\u003c\/li\u003e\n\u003cli\u003eFasTest® for quicker testing\u003c\/li\u003e\n\u003cli\u003eTricoloured LED status indicator\u003c\/li\u003e\n\u003cli\u003eComprehensively tested to exceed EN 54-7 standard\u003c\/li\u003e\n\u003cli\u003eRuggedized metal face plate which is secured with anti-tamper screws\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57549198426485,"sku":"FL6100-600APO","price":356.48,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/FL6100-600APO.jpg?v=1788541314"},{"product_id":"apollo-fire-optical-smoke-detector-55000-600apo","title":"Apollo Fire 55000-600APO optical smoke detector, White","description":"\u003cp\u003e\u003cstrong\u003eApollo Fire 55000-600APO is an optical smoke detector from the XP95 range.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe XP95 Optical Smoke Detector works on the light scatter principle and is ideal for applications where slow burning or smouldering fires are likely. It is suitable for medium-to-large applications with simple installation requirements. As it operates using digital communication, XP95 has a high immunity from corruption, and is, therefore, often preferred in a large system where life safety is critical.\u003c\/p\u003e\n\u003cp\u003eXP95 products are frequently used in commercial, industrial, financial, government, IT\/telecoms and healthcare applications. Device Addressing: Each XP95 device responds to interrogation and command from central control equipment.\u003c\/p\u003e\n\u003cp\u003eIt communicates to the panel information on status, command bits, type, location, and other information that allows an alarm to be raised even when the device is not itself being interrogated. Message error checking is also provided. The devices are compatible with Discovery® systems and control equipment to aid maintenance, extension and upgrade of existing systems.\u003c\/p\u003e\n\u003cp\u003eA unique, patented XPERT card provides simple, user friendly and accurate identification of detector location whereby a coded card, inserted in the base, is read by any detector once it is plugged in. All the electronic components are in the detector but the location information is held in the base. The address card simplifies and speeds up installation and commissioning.\u003c\/p\u003e\n\u003cp\u003eAddressing errors during maintenance and service are eliminated.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAlarm address for fast location of alarm\u003c\/li\u003e\n\u003cli\u003eXPERT 7 Card addressing\u003c\/li\u003e\n\u003cli\u003eElectronics-free base\u003c\/li\u003e\n\u003cli\u003eEasy installation\u003c\/li\u003e\n\u003cli\u003eElegant design\u003c\/li\u003e\n\u003cli\u003eResponds well to slow burning, smouldering fires\u003c\/li\u003e\n\u003cli\u003eWell suited to escape routes\u003c\/li\u003e\n\u003cli\u003eUnaffected by wind or atmospheric pressure\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57558655598965,"sku":"55000-600APO","price":32.02,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/55000-600APO.jpg?v=1788880458"},{"product_id":"apollo-fire-optical-smoke-detector-55000-620apo","title":"Apollo Fire 55000-620APO optical smoke detector, White","description":"\u003cp\u003e\u003cstrong\u003eApollo Fire 55000-620APO is an optical smoke detector from the XP95 range.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe XP95 Optical Smoke Detector uses the light scatter principle to quickly and effectively detect a range of slow burning and smouldering fires.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eReliable fire detection in areas with a wide temperature range from -20°C to +60°C\u003c\/li\u003e\n\u003cli\u003eUnaffected by wind and atmospheric pressure\u003c\/li\u003e\n\u003cli\u003eIdeal for escape routes\u003c\/li\u003e\n\u003cli\u003eInsect resistant screen\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57558659727733,"sku":"55000-620APO","price":32.79,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/55000-620APO.jpg?v=1788880498"},{"product_id":"apollo-fire-optical-smoke-detector-sa5100-600apo","title":"Apollo Fire SA5100-600APO optical smoke detector, White","description":"\u003cp\u003e\u003cstrong\u003eApollo Fire SA5100-600APO is an optical smoke detector from the Soteria range.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Soteria Optical Smoke Detector uses advanced optical sensing technology, PureLight, to provide advanced false alarm management and increased detector reliability.\u003c\/p\u003e\n\u003ch3\u003eKey features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eUtilises digital Core Protocol communications providing a range of advanced fire detection features\u003c\/li\u003e\n\u003cli\u003eA sophisticated dynamic algorithm, providing transient rejection and compensation for drift while maintaining accurate sensitivity\u003c\/li\u003e\n\u003cli\u003e“Serpentine” pathway designed to provide a barrier against dust and insect ingress\u003c\/li\u003e\n\u003cli\u003eFasTest for quicker testing of detectors\u003c\/li\u003e\n\u003cli\u003eFive response modes for adaptability to changing environments\u003c\/li\u003e\n\u003cli\u003eIntegrated switchable isolator\u003c\/li\u003e\n\u003c\/ul\u003e\n","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57559622353269,"sku":"SA5100-600APO","price":39.22,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/SA5100-600APO.jpg?v=1788903768"},{"product_id":"apollo-fire-smoke-detectors-point-detector-xpa-oh-13032-apo","title":"Apollo Fire XPA-OH-13032-APO smoke detectors – point detector","description":"\u003cp\u003e\u003cstrong\u003ePlease note: this is a non-returnable item (excluding faulty goods)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApollo Fire XPA-OH-13032-APO is a smoke detectors – point detector.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe figures we hold for this smoke detectors – point detector cover product type, application\/usage, certifications \u0026amp; standards, additional information.\u003c\/p\u003e\n\u003cp\u003eIf you are matching this to an existing installation, work from the XPA-OH-13032-APO part number rather than the description.\u003c\/p\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57621789114741,"sku":"XPA-OH-13032-APO","price":78.84,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/XPA-OH-13032-APO.jpg?v=1790944322"},{"product_id":"apollo-optical-smoke-detector-55000-660apo","title":"Apollo XP95 Optical Smoke Detector, Black 55000-660APO","description":"\u003cp\u003eThe Apollo XP95 55000-660APO is an optical smoke detector for addressable fire alarm systems. It suits applications where slow burning or smouldering fires are likely, and is well suited to escape routes. This is the black version, and it works with XP95, Discovery and CoreProtocol communication.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePicks up the fires it is built for – responds well to slow burning, smouldering fires\u003c\/li\u003e\n\u003cli\u003eSuits the way out of a building – well suited to escape routes\u003c\/li\u003e\n\u003cli\u003eHolds steady when air pressure changes – unaffected by wind or atmospheric pressure\u003c\/li\u003e\n\u003cli\u003eEasy to see its state – the indicator LED is clear in standby and red in alarm\u003c\/li\u003e\n\u003cli\u003eRoom for a repeat light – a drive point for a remote LED indicator\u003c\/li\u003e\n\u003cli\u003eA darker look – the black version, Part No. 55000-660\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: two wire supply, 17 V to 28 V dc. Quiescent current 340 µA, alarm LED current 4 mA.\u003c\/li\u003e\n\u003cli\u003eMounting: connects through terminals L1 and L2 in the mounting base, following the base's terminal marking. Size 100 mm diameter x 42 mm height.\u003c\/li\u003e\n\u003cli\u003eCompatibility: XP95, Discovery and CoreProtocol compatible.\u003c\/li\u003e\n\u003cli\u003eStandards: sensitivity is measured in accordance with EN 54-7. For this part, approvals are CPR and LPCB only.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat sort of fire does an optical smoke detector suit?\u003c\/h4\u003e\n\u003cp\u003eSlow burning and smouldering fires. This one works on the light scatter principle, so it responds well to those fires and is well suited to escape routes.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhich fire alarm protocols does the 55000-660APO work with?\u003c\/h4\u003e\n\u003cp\u003eXP95, Discovery and CoreProtocol. Check your panel uses one of these before ordering.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat voltage does it run on?\u003c\/h4\u003e\n\u003cp\u003e17 V to 28 V dc on a two wire supply. Follow the base's terminal marking when wiring.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it connect straight to the cable?\u003c\/h4\u003e\n\u003cp\u003eNo. It connects through terminals L1 and L2 in the mounting base.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow does the detector show it is in alarm?\u003c\/h4\u003e\n\u003cp\u003eThe indicator LED turns red. It is clear in standby.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhich approvals does this black version hold?\u003c\/h4\u003e\n\u003cp\u003eCPR and LPCB only for part 55000-660, so check them against your specification.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57709171048821,"sku":"55000-660APO","price":47.28,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-55000-660apo-optical-smoke-detector-angled-view.jpg?v=1793527857"},{"product_id":"apollo-series-65-detector-base-45681-200apo","title":"Apollo Series 65 Smoke Detector Base, Standard Mounting Base 100mm 45681-200APO","description":"\u003cp\u003eThe Apollo 45681-200APO is a smoke detector base for Series 65 conventional fire detectors. It suits installers fitting or replacing detector positions on a conventional system. The 100mm base has five marked terminals, and detectors fit one way only with a clockwise turn and no push force.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eKinder on ceilings – detectors fit without the need of force, particularly useful on suspended ceilings\u003c\/li\u003e\n\u003cli\u003eOnly goes on one way – detectors fit into bases one way only, with clockwise rotation\u003c\/li\u003e\n\u003cli\u003eCan be locked – a grub screw locks the detector in, using a 1.5mm hexagonal driver\u003c\/li\u003e\n\u003cli\u003eRoom to wire – a wide interior diameter for ease of access to cables and terminals\u003c\/li\u003e\n\u003cli\u003eClear markings – five terminals, each marked with its function\u003c\/li\u003e\n\u003cli\u003eSimple inside – contains no electrical parts\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMounting: two slots for fixing screws at a spacing of 51 to 69mm. 100mm diameter.\u003c\/li\u003e\n\u003cli\u003eCabling: terminals for line 1 in, line 1 out, line 2 in and out, remote indicator negative and earth.\u003c\/li\u003e\n\u003cli\u003eCompatibility: all detectors in the Series 65 range fit Series 60 standard mounting bases.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhich detectors fit this base?\u003c\/h4\u003e\n\u003cp\u003eSeries 65 detectors. All detectors in the range fit into Series 60 standard mounting bases, and this part is the Series 65 mounting base.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes the wiring have a polarity?\u003c\/h4\u003e\n\u003cp\u003eNot for the detectors. Positive and negative lines only need identifying if a remote LED is fitted.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it need an earth connection?\u003c\/h4\u003e\n\u003cp\u003eNo. The earth terminal is there for tidy termination of earthed conductors or cable screens, and to maintain earth continuity where necessary.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan the detector be locked in?\u003c\/h4\u003e\n\u003cp\u003eYes. A grub screw locks it, using a 1.5mm hexagonal driver, part no 29600-095.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eIs a detector included?\u003c\/h4\u003e\n\u003cp\u003eNo. This is the mounting base only, so the detector head is a separate item.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57711078670709,"sku":"45681-200APO","price":2.55,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-45681-200apo-series-65-detector-base-angled-view-showing-terminals.jpg?v=1793620191"},{"product_id":"apollo-optical-smoke-detector-55000-316apo","title":"Apollo Series 65 Optical Smoke Detector with Flashing LED 55000-316APO","description":"\u003cp\u003eThe Apollo 55000-316APO is a Series 65 optical smoke detector with a flashing LED, for conventional fire alarm systems. It suits installers fitting or replacing detector heads where slow burning, smouldering fires are the main risk. It runs on 9 V to 33 V dc and is unaffected by wind or atmospheric pressure.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePicks up the fires it is built for – responds well to slow burning, smouldering fires\u003c\/li\u003e\n\u003cli\u003eHolds steady in moving air – unaffected by wind or atmospheric pressure\u003c\/li\u003e\n\u003cli\u003eChecks before it alarms – two more bursts of light at two-second intervals confirm the first reading\u003c\/li\u003e\n\u003cli\u003eEasy to see its state – a clear LED emitting red light in alarm\u003c\/li\u003e\n\u003cli\u003eSimple to wire – two wire supply, polarity insensitive\u003c\/li\u003e\n\u003cli\u003eKeeps out light and insects – a labyrinth chamber with a fine gauze cover\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: 9 V to 33 V dc, quiescent current 30 - 50 µA at 24 V. Normal alarm current 52 mA at 24 V.\u003c\/li\u003e\n\u003cli\u003eMounting: 100 mm diameter x 42 mm height, 50 mm high with mounting base. Rated IP23D.\u003c\/li\u003e\n\u003cli\u003eCabling: two wire supply, polarity insensitive. L1 IN and L2 are supply in, L1 OUT and L2 supply out, and -R is the remote indicator negative.\u003c\/li\u003e\n\u003cli\u003eCompatibility: a Series 65 detector on a conventional circuit. The panel must supply a maximum of 33 V dc and a minimum of 9 V dc in normal operation.\u003c\/li\u003e\n\u003cli\u003eStandards: sensitivity measured in accordance with EN 54-7. Approvals: LPCB, VdS, DIBt, BOSEC, FG, CPR and SBSC.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat kind of fire does an optical smoke detector suit?\u003c\/h4\u003e\n\u003cp\u003eSlow burning, smouldering fires. It is also rated Very Good for overheating, but Poor for clean burning flaming fires.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is the detector reset after an alarm?\u003c\/h4\u003e\n\u003cp\u003eExpel any smoke, then interrupt the electrical supply to the detector for a minimum of one second.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat does the flashing LED version do differently?\u003c\/h4\u003e\n\u003cp\u003eThis part is the version with a flashing LED. In alarm, its clear LED emits red light. Check the flash pattern with Apollo if it matters.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes the wiring have a polarity?\u003c\/h4\u003e\n\u003cp\u003eNo. It is a two wire supply and is polarity insensitive.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it go on an escape route?\u003c\/h4\u003e\n\u003cp\u003eThe system design decides which detector goes on an escape route, so check with whoever holds the fire strategy.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat voltage should the supply stay above?\u003c\/h4\u003e\n\u003cp\u003e12 V, for effective lighting of the integral LED and any remote indicator. Its normal range is 9 V to 33 V dc.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57711429943669,"sku":"55000-316APO","price":15.87,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-55000-316apo-optical-smoke-detector-side-view.jpg?v=1793628775"},{"product_id":"apollo-optical-smoke-detector-orb-op-12001-apo","title":"Apollo Orbis Optical Smoke Detector, Two Wire, IP44 ORB-OP-12001-APO","description":"\u003cp\u003eThe Apollo ORB-OP-12001-APO is an Orbis optical smoke detector for conventional fire alarm systems, recommended by Apollo as a general purpose smoke detector for early warning of fires in most areas. It suits installers wanting fewer false alarms. It runs on a two wire supply from 8.5 V dc to 33 V dc.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBetter on dark smoke – improved sensitivity to black smoke\u003c\/li\u003e\n\u003cli\u003eCopes as it ages – compensation for build-up of dirt\u003c\/li\u003e\n\u003cli\u003eFewer nuisance alarms – extra confirmation of smoke before an alarm signal is given\u003c\/li\u003e\n\u003cli\u003eEasy to see from below – integral indicator with 360º visibility\u003c\/li\u003e\n\u003cli\u003eQuick to check – FasTest takes just four seconds to test that it is functioning correctly\u003c\/li\u003e\n\u003cli\u003eShows wiring faults early – StartUp confirms that the detectors are wired in the correct polarity\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: 8.5 V dc to 33 V dc. Average quiescent current at 24 V is 95 µA, and alarm current is 40 mA at 24V.\u003c\/li\u003e\n\u003cli\u003eMounting: 97 mm diameter x 31 mm height, 75 g. IP44.\u003c\/li\u003e\n\u003cli\u003eCabling: two wire supply, polarity sensitive. Remote output LED (-) is 1.2 kΩ connected to negative supply.\u003c\/li\u003e\n\u003cli\u003eCompatibility: a conventional detector. Check your panel's documentation for compatibility, and allow a suitable base.\u003c\/li\u003e\n\u003cli\u003eStandards: EN54-7, with CPR, LPCB, VdS, BOSEC, SBSC and FG for this part number.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes the polarity matter when wiring it?\u003c\/h4\u003e\n\u003cp\u003eYes. It is polarity sensitive, and StartUp flashes the red LED once per second to confirm that the wiring is in the correct polarity.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eIs the LED flashing in normal use?\u003c\/h4\u003e\n\u003cp\u003eNo. This part has no flashing LED as standard. There is a separate flashing LED version, ORB-OP-12003-APO.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is a dirty detector shown?\u003c\/h4\u003e\n\u003cp\u003eBy the yellow LED. DirtAlert shows that the drift compensation limit has been reached, flashing once per second in StartUp.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it be used on an escape route?\u003c\/h4\u003e\n\u003cp\u003eOptical detectors are regarded as particularly suitable for smouldering fires and escape routes, but the system design for the building decides each position.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhich temperatures can it work in?\u003c\/h4\u003e\n\u003cp\u003eFrom -40ºC to +70ºC, with humidity from 0% to 98% RH and no condensation or icing.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it come with a base?\u003c\/h4\u003e\n\u003cp\u003eAs a rule, detector heads are sold without one, so check before ordering.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57711448326517,"sku":"ORB-OP-12001-APO","price":16.27,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-orb-op-12001-apo-optical-smoke-detector-angled-view.jpg?v=1793629516"},{"product_id":"apollo-wireless-optical-smoke-detector-rw1000-600apo","title":"Apollo REACH Wireless Optical Smoke Detector with Base, White RW1000-600APO","description":"\u003cp\u003eThe Apollo RW1000-600APO is a REACH wireless optical smoke detector for addressable fire systems where running cable is awkward. It suits installers extending a loop to hard-to-wire areas. It comes with a base and two batteries, and links to the panel by radio through the RW1700-030APO Loop-Interface, up to 100 m in open space.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNo detector cable to run – bi-directional wireless communication with the Loop-Interface\u003c\/li\u003e\n\u003cli\u003eDesigned to reject false alarms – a dual-optical chamber with advanced drift compensation\u003c\/li\u003e\n\u003cli\u003eBackup on the radio link – dual channel redundancy\u003c\/li\u003e\n\u003cli\u003eYears between battery changes – 10 years in normal operation with good signal strength (no dropped messages)\u003c\/li\u003e\n\u003cli\u003eVisible from any side – twin alarm, bi-colour LEDs for 360° visibility\u003c\/li\u003e\n\u003cli\u003eTells you if it is taken down – removal from its base sends a tamper detection message\u003c\/li\u003e\n\u003cli\u003eReady to fit – supplied with a standard wireless base and two CR123 batteries\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: 2x VARTA CR123A Lithium 3 V, 1250mAh typical. Both batteries are required.\u003c\/li\u003e\n\u003cli\u003eMounting: supplied with a standard wireless base. 110 mm diameter x 70 mm height, 190 g including base and batteries.\u003c\/li\u003e\n\u003cli\u003eCabling: none to the detector. Range to the Loop-Interface is 100 m (in open space).\u003c\/li\u003e\n\u003cli\u003eCompatibility: Apollo protocol compatibility is handled via the RW1700-030APO Loop-Interface. Apollo XPERT cards are not supported. AV bases: RW1300-110APO, RW1300-210APO and RW1300-211APO.\u003c\/li\u003e\n\u003cli\u003eStandards: EN54-7 and EN54-25.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes the RW1000-600APO talk directly to a fire panel?\u003c\/h4\u003e\n\u003cp\u003eNo. It connects by radio to the RW1700-030APO Loop-Interface, which translates that into wired Apollo protocol communication for the panel.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow long do the batteries last?\u003c\/h4\u003e\n\u003cp\u003e10 years in normal operation with good signal strength (no dropped messages). When the low power fault appears, both batteries need replacing.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it come with a base?\u003c\/h4\u003e\n\u003cp\u003eYes. It is supplied with a standard wireless base, and with two CR123 batteries.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow far can it be from the Loop-Interface?\u003c\/h4\u003e\n\u003cp\u003eUp to 100 m in open space. Walls and floors are not open space, so survey the route.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan XPERT cards be used to set the address?\u003c\/h4\u003e\n\u003cp\u003eNo. Addressing is soft, set automatically when pairing with the Loop Interface, and can be changed manually.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is a low battery reported?\u003c\/h4\u003e\n\u003cp\u003eThe Loop-Interface receives a low battery message, shows it on its display and relays it to the fire control panel.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57711450620277,"sku":"RW1000-600APO","price":153.53,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-rw1000-600apo-wireless-optical-smoke-detector-side-view.png?v=1793629569"},{"product_id":"apollo-optical-smoke-detector-55000-317apo","title":"Apollo Series 65 Optical Smoke Detector, Conventional, White 55000-317APO","description":"\u003cp\u003eThe Apollo Series 65 55000-317APO is an optical smoke detector. It looks for light scattered by smoke particles, and Apollo rates it well suited for bedrooms and escape routes. It runs on 9 V to 33 V dc, and the white polycarbonate housing is 100 mm in diameter.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSees smoke by scattered light – photo-electric detection in a forward direction\u003c\/li\u003e\n\u003cli\u003eChecks before it signals – sampling once every three seconds, confirmation once every two seconds\u003c\/li\u003e\n\u003cli\u003eSteady in moving air – unaffected by wind speed or atmospheric pressure\u003c\/li\u003e\n\u003cli\u003eEasy to wire – two wire supply, polarity insensitive\u003c\/li\u003e\n\u003cli\u003eShows when it has triggered – a clear LED emitting red light\u003c\/li\u003e\n\u003cli\u003eKeeps insects and stray light out – a labyrinth chamber with a fine gauze insect-resistant cover\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: 9 V to 33 V dc. Quiescent 30 - 50 µA at 24 V. Alarm current 52 mA at 24 V.\u003c\/li\u003e\n\u003cli\u003eMounting: 100 mm diameter x 42 mm height, 50 mm high with mounting base. 99 g, 150 g with base.\u003c\/li\u003e\n\u003cli\u003eCabling: L1 IN and L2 supply in, L1 OUT and L2 supply out, -R for a remote indicator. Two wire supply, polarity insensitive.\u003c\/li\u003e\n\u003cli\u003eStandards: EN 54-7, LPCB, VdS, DIBt, BOSEC, FG, CPR and SBSC. IP23D.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes the 55000-317APO have a flashing LED?\u003c\/h4\u003e\n\u003cp\u003eNo. This is the plain Optical Smoke Detector. The flashing LED version is part 55000-316, and the version with a magnetic test switch is part 55000-315.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow does it rate on different types of fire?\u003c\/h4\u003e\n\u003cp\u003eApollo rates it Very Good on overheating and flaming combustion, Moderate\/Good on smouldering and glowing combustion, and Poor on clean burning flames.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is it reset after an alarm?\u003c\/h4\u003e\n\u003cp\u003eExpel any smoke, then interrupt the electrical supply to the detector for a minimum of one second.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it go in a bedroom or on an escape route?\u003c\/h4\u003e\n\u003cp\u003eYes, Apollo rates it well suited for both. Positions on a real job still come from the system design.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat temperature range does it handle?\u003c\/h4\u003e\n\u003cp\u003e-20°C to + 60°C, at 0% to 95% RH with no condensation or icing.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan a remote indicator be added?\u003c\/h4\u003e\n\u003cp\u003eYes. Connect a remote indicator between the L1 IN terminal and the -R terminal. For effective illumination the supply should exceed 12 V.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57714821595509,"sku":"55000-317APO","price":15.59,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-55000-317apo-optical-smoke-detector-angled-view.jpg?v=1793701348"},{"product_id":"apollo-integrating-optical-smoke-detector-55000-391apo","title":"Apollo AlarmSense Integrating Optical Smoke Detector 55000-391APO","description":"\u003cp\u003eThe Apollo AlarmSense 55000-391APO is an integrating optical smoke detector for two wire AlarmSense fire alarm systems. It suits sites where brief smoke could otherwise cause trouble, because it discards transient smoke and waits 20 seconds before alarming. It only works with purpose designed AlarmSense fire control panels.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFewer unwanted alarms – monitors and discards transient smoke\u003c\/li\u003e\n\u003cli\u003eA pause before alarm – a 20 second delay before changing into an alarm state\u003c\/li\u003e\n\u003cli\u003eSuits the fires it is built for – responds well to slow-burning, smouldering fires\u003c\/li\u003e\n\u003cli\u003eFor sleeping areas and ways out – suitable for bedrooms and escape routes\u003c\/li\u003e\n\u003cli\u003eEasy to see from any side – 360º visibility of LEDs\u003c\/li\u003e\n\u003cli\u003eSimple to fit – quick and simple installation on a two wire supply\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: 9 V dc - 33 V dc, two wire supply, polarity insensitive (the wires can go either way round). Quiescent current at 15 V is \u0026lt; 50 µA.\u003c\/li\u003e\n\u003cli\u003eMounting: 100 mm diameter x 42 mm height, or 100 mm diameter x 50 mm height in base. Weight 90 g detector.\u003c\/li\u003e\n\u003cli\u003eCompatibility: only for a system powered and controlled by purpose designed AlarmSense fire control panels. Confirm the panel is AlarmSense before ordering.\u003c\/li\u003e\n\u003cli\u003eStandards: EN 54-7, CPR, FG. Designed to IP44.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhich fire alarm panels does it work with?\u003c\/h4\u003e\n\u003cp\u003eOnly purpose designed AlarmSense fire control panels. Confirm that the system is AlarmSense before ordering.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat does integrating mean on this detector?\u003c\/h4\u003e\n\u003cp\u003eIt monitors and discards transient smoke. It also has a 20 second delay before changing into an alarm state.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eIs it suitable for bedrooms?\u003c\/h4\u003e\n\u003cp\u003eYes. It is suitable for bedrooms and escape routes, though the final position should follow the system design.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat sort of fire does it suit?\u003c\/h4\u003e\n\u003cp\u003eSlow-burning, smouldering fires. It works on the light scatter principle and responds well to those fires.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat voltage does it run on?\u003c\/h4\u003e\n\u003cp\u003e9 V dc - 33 V dc on a two wire supply. The wiring is polarity insensitive.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it be fitted outdoors?\u003c\/h4\u003e\n\u003cp\u003eCheck the location against its ratings first. It is designed to IP44 and rated -10 ºC to +55 ºC, with no condensation or icing.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57714821857653,"sku":"55000-391APO","price":15.94,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-55000-391apo-integrating-optical-smoke-detector-angled-view.jpg?v=1793701357"},{"product_id":"apollo-marine-optical-smoke-detector-orb-op-42003-mar","title":"Apollo Orbis Marine Optical Smoke Detector, Flashing LED, MED Approved ORB-OP-42003-MAR","description":"\u003cp\u003eThe Apollo ORB-OP-42003-MAR is an Orbis Marine optical smoke detector for early warning of fires on board. It suits marine installers who want a visible sign that each head is alive, as its red LED flashes in normal operation. It works from 8.5 V dc to 33 V dc.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLess likely to miss dark smoke – improved sensitivity to black smoke\u003c\/li\u003e\n\u003cli\u003eFewer nuisance alarms – extra confirmation of smoke before an alarm signal is given\u003c\/li\u003e\n\u003cli\u003eStays consistent over time – compensation for slow changes in sensitivity\u003c\/li\u003e\n\u003cli\u003eShows it is alive – red LED flashes every four seconds in normal operation\u003c\/li\u003e\n\u003cli\u003eMarine approvals – EN54-7, MED, LR, BV, ABS, CCS and CRS\u003c\/li\u003e\n\u003cli\u003eTakes harsh conditions – -40ºC to +70ºC and 0% to 98% RH\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: 8.5 V dc to 33 V dc, two wire supply, polarity sensitive. 95 µA average quiescent current at 24 V, 40 mA alarm current at 24V.\u003c\/li\u003e\n\u003cli\u003eMounting: 97 mm diameter x 31 mm height, or 100 mm diameter x 46 mm height in base. 75 g detector, 135 g detector with base.\u003c\/li\u003e\n\u003cli\u003eCabling: two wire and polarity sensitive, with a remote output of 1.2 kΩ connected to negative supply.\u003c\/li\u003e\n\u003cli\u003eStandards: EN54-7, MED, LR, BV, ABS, CCS and CRS. CRS approval is for this code only in the Orbis Marine pair.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eIs this detector approved for marine use?\u003c\/h4\u003e\n\u003cp\u003eIt carries EN54-7, MED, LR, BV, ABS, CCS and CRS approvals, and complies with the Marine Equipment Directive 2014\/90\/EU. Check the vessel's class society accepts them for the job.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat does the flashing LED do?\u003c\/h4\u003e\n\u003cp\u003eIt shows the detector is powered in normal operation, with a red flash every four seconds. The alarm LED itself has 360º visibility.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes polarity matter?\u003c\/h4\u003e\n\u003cp\u003eYes. It is a two wire, polarity sensitive device. At power up, StartUp confirms the wiring polarity is correct.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is it tested?\u003c\/h4\u003e\n\u003cp\u003eFasTest is a maintenance procedure that takes just four seconds to functionally test the detector.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow does it show a dirty sensor?\u003c\/h4\u003e\n\u003cp\u003eDirtAlert shows the drift compensation limit has been reached, using the yellow LED, and SensAlert indicates the sensor is not operating correctly.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57723822014837,"sku":"ORB-OP-42003-MAR","price":39.58,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-orb-op-42003-mar-marine-optical-smoke-detector-detector-view.jpg?v=1793793487"},{"product_id":"apollo-optical-heat-multisensor-detector-sa5100-760apo","title":"Apollo Soteria Smoke Heat Detector, Multisensor, Isolated, Black SA5100-760APO","description":"\u003cp\u003eThe Apollo SA5100-760APO is a black smoke heat detector for addressable fire systems, combining PureLight optical sensing with two thermistors. It can be switched to detect smoke, heat or both across five modes. It has an integrated short-circuit isolator and is compatible with XP95, Discovery and CoreProtocol.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFewer false alarms – PureLight optical technology reduces false alarms and enhances smoke recognition\u003c\/li\u003e\n\u003cli\u003eOne head, five behaviours – pure smoke, pure heat or a combination, chosen at the panel\u003c\/li\u003e\n\u003cli\u003eReliable heat sensing – dual heat sensors\u003c\/li\u003e\n\u003cli\u003eLimits the effect of a fault – short-circuit isolator integrated into the head\u003c\/li\u003e\n\u003cli\u003eFaster testing – FasTest for quicker testing of detectors\u003c\/li\u003e\n\u003cli\u003eClear status – tricoloured LED: red in alarm, yellow for a fault, green for protocol activity\u003c\/li\u003e\n\u003cli\u003eA darker look – the isolated black version\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: two-wire loop carrying data and power, 17 V – 35 V dc. Quiescent 350 µA, power-up surge 560 µA, alarm 3.5 mA with LED illuminated.\u003c\/li\u003e\n\u003cli\u003eMounting: 100 mm diameter x 38.5 mm height, 96 g (+\/- 10 %). Works on XPERT 8 or XPERT 7 bases.\u003c\/li\u003e\n\u003cli\u003eCompatibility: XP95, Discovery and CoreProtocol compatible. Not all features work on XP95 or Discovery panels.\u003c\/li\u003e\n\u003cli\u003eStandards: EN 54-5:2017, EN 54-7:2018.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat are the five modes?\u003c\/h4\u003e\n\u003cp\u003eModes 1, 3 and 4 combine smoke and heat, mode 2 is smoke only and mode 5 is heat only. The mode is selected at the fire control panel.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWill it work on an existing XP95 or Discovery system?\u003c\/h4\u003e\n\u003cp\u003eYes, it has been designed to operate on XP95 and Discovery loops. Not all features will work on those panels.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes a slow rise in temperature trigger it in modes 1, 3 and 4?\u003c\/h4\u003e\n\u003cp\u003eNo. In those modes it will not respond to a slow temperature increase, even if the temperature reaches a high level.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat does mode 5 do?\u003c\/h4\u003e\n\u003cp\u003eIt gives a pure heat response meeting Category A1R, with a fixed temperature alarm threshold at 57°C and rate-of-rise characteristics.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is it cleaned?\u003c\/h4\u003e\n\u003cp\u003eExternally with a soft damp cloth. Full cleaning and recalibration means returning it to the maker.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57725801169269,"sku":"SA5100-760APO","price":53.05,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-sa5100-760apo-optical-heat-multisensor-detector-front-view.png?v=1793818696"},{"product_id":"apollo-duct-smoke-detector-housing-53546-022apo","title":"Apollo Analogue Addressable Duct Smoke Detector Housing 53546-022APO","description":"\u003cp\u003eThe Apollo 53546-022APO is a duct smoke detector housing for early detection of smoke in heating and ventilation ducts. It suits commercial and industrial premises with analogue addressable fire alarm systems. It accepts an analogue addressable detector head and works in air speeds of 0.5m\/s to 20m\/s, as supplementary detection only.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eStops smoke being carried around a building – helps prevent the recirculation of smoke to areas unaffected\u003c\/li\u003e\n\u003cli\u003eWorks in moving air – operates in air speeds of 0.5m\/s to 20m\/s\u003c\/li\u003e\n\u003cli\u003eSuits a range of ducts – designed for widths between 300mm and 3000mm\u003c\/li\u003e\n\u003cli\u003eReady for most jobs – a 360mm sampling tube, suitable for duct widths up to 540mm, is supplied as standard\u003c\/li\u003e\n\u003cli\u003eEasy to check at a glance – transparent cover to view the detector head LED\u003c\/li\u003e\n\u003cli\u003eTesting built in – integrated smoke test port\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eMounting: fitted to the side, the top or the bottom of the ventilation duct, with holes for two tubes through the duct wall.\u003c\/li\u003e\n\u003cli\u003eCabling: accepts solid or stranded wiring up to 2.5mm².\u003c\/li\u003e\n\u003cli\u003eCompatibility: XP95 heads 55000-500, -520, 55000-600 and -620. Discovery heads 58000-500 and 58000-600.\u003c\/li\u003e\n\u003cli\u003ePower: housing with a base fitted, so electrical data comes from the detector head chosen.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it be the only fire detection in a building?\u003c\/h4\u003e\n\u003cp\u003eNo. A duct smoke detection system must never be the sole method of detecting fire. It should be supplementary detection in a fire detection system.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhich detector heads fit?\u003c\/h4\u003e\n\u003cp\u003eAnalogue addressable heads. The XP95 optical heads are 55000-600 and -620, and the Discovery optical head is 58000-600.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat width of duct does it suit?\u003c\/h4\u003e\n\u003cp\u003eBetween 300mm and 3000mm. The standard 360mm tube suits widths up to 540mm, and longer tubes are ordered separately.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat airflow does it need?\u003c\/h4\u003e\n\u003cp\u003eA uniform, non-turbulent airflow between 0.5 and 20m\/s. The pressure differential between the tubes should be between 0.025 and 3mbar.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhere should it go along the duct?\u003c\/h4\u003e\n\u003cp\u003eAs far as possible downstream from any obstruction, such as bends or dampers, so turbulence has less effect.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57727845138805,"sku":"53546-022APO","price":72.52,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-53546-022apo-duct-smoke-detector-housing-housing-with-sampling-and-exhaust-tubes.jpg?v=1793827338"},{"product_id":"apollo-optical-smoke-detector-55000-315apo","title":"Apollo Series 65 Optical Smoke Detector, Magnetic Test Switch and Flashing LED 55000-315APO","description":"\u003cp\u003eThe Apollo 55000-315APO is a Series 65 optical smoke detector with a magnetic test switch and flashing LED, for conventional fire alarm systems. It suits installers fitting or replacing detector heads where slow burning, smouldering fires are the main risk. It runs on 9 V to 33 V dc and is unaffected by wind.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePicks up the fires it is built for – responds well to slow burning, smouldering fires\u003c\/li\u003e\n\u003cli\u003eHolds steady in moving air – unaffected by wind or atmospheric pressure\u003c\/li\u003e\n\u003cli\u003eChecks before it alarms – two more bursts of light at two-second intervals confirm the first reading\u003c\/li\u003e\n\u003cli\u003eIncludes a test option – this part has a magnetic test switch and flashing LED\u003c\/li\u003e\n\u003cli\u003eSimple to wire – two wire supply, polarity insensitive\u003c\/li\u003e\n\u003cli\u003eKeeps out light and insects – a labyrinth chamber with a fine gauze cover\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: 9 V to 33 V dc, quiescent current 30 - 50 µA at 24 V. Normal alarm current 52 mA at 24 V.\u003c\/li\u003e\n\u003cli\u003eMounting: 100 mm diameter x 42 mm height, 50 mm high with mounting base. Rated IP23D.\u003c\/li\u003e\n\u003cli\u003eCabling: two wire supply, polarity insensitive. L1 IN and L2 are supply in, L1 OUT and L2 supply out, and -R is the remote indicator negative.\u003c\/li\u003e\n\u003cli\u003eCompatibility: a Series 65 detector on a conventional circuit. The panel must supply a maximum of 33 V dc and a minimum of 9 V dc in normal operation.\u003c\/li\u003e\n\u003cli\u003eStandards: sensitivity measured in accordance with EN 54-7. Approvals: LPCB, VdS, DIBt, BOSEC, FG, CPR and SBSC.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat kind of fire does an optical smoke detector suit?\u003c\/h4\u003e\n\u003cp\u003eSlow burning, smouldering fires. It is also rated Very Good for overheating, but Poor for clean burning flaming fires.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is the detector reset after an alarm?\u003c\/h4\u003e\n\u003cp\u003eExpel any smoke, then interrupt the electrical supply to the detector for a minimum of one second.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat sets this version apart?\u003c\/h4\u003e\n\u003cp\u003eIt has both a magnetic test switch and a flashing LED. The other two versions are 55000-316, with flashing LED, and 55000-317.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes the wiring have a polarity?\u003c\/h4\u003e\n\u003cp\u003eNo. It is a two wire supply and is polarity insensitive.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it go on an escape route?\u003c\/h4\u003e\n\u003cp\u003eIt is well suited for bedrooms and escape routes. The system design still decides which detector goes where, so check with whoever holds the fire strategy.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat voltage should the supply stay above?\u003c\/h4\u003e\n\u003cp\u003e12 V, for effective lighting of the integral LED and any remote indicator. Its normal range is 9 V to 33 V dc.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57727873450357,"sku":"55000-315APO","price":19.94,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-55000-315apo-optical-smoke-detector-side-view.jpg?v=1793827446"},{"product_id":"apollo-intrinsically-safe-optical-smoke-detector-55000-640apo","title":"Apollo XP95 I.S. Optical Smoke Detector, Intrinsically Safe 55000-640APO","description":"\u003cp\u003eThe Apollo XP95 I.S. 55000-640APO is an intrinsically safe optical smoke detector for loop-wired fire systems. It works on the light scatter principle, so it suits places where slow burning or smouldering fires are likely, and it is well suited to escape routes. It runs on 14 V - 22 V.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePicks up slow fires – for applications where slow burning or smouldering fires are likely\u003c\/li\u003e\n\u003cli\u003eSuits the way out of a building – well suited to escape routes\u003c\/li\u003e\n\u003cli\u003eSteady in moving air – unaffected by wind or atmospheric pressure\u003c\/li\u003e\n\u003cli\u003eHazardous area classification – Ex ia IIC T4 GA up to +60°C, Ex ia IIC T5 GA up to +45°C\u003c\/li\u003e\n\u003cli\u003eLow loop load – 340 µA quiescent current and 1 mA alarm LED current\u003c\/li\u003e\n\u003cli\u003eRoom for a repeat light – a drive point for a remote LED, with current limited to 1 mA\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: two wire supply, polarity sensitive, 14 V - 22 V.\u003c\/li\u003e\n\u003cli\u003eMounting: connects through terminals L1 and L2 in the mounting base. Size 100 mm diameter x 42 mm height.\u003c\/li\u003e\n\u003cli\u003eCabling: L1 positive supply, L2 negative supply and remote LED negative, +R remote LED positive.\u003c\/li\u003e\n\u003cli\u003eStandards: EN 54, ATEX, IECEx, LPCB and CPR among others. Certificates BAS02ATEX1289X and IECEx BAS 12.0091X.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat sort of fire does this optical smoke detector suit?\u003c\/h4\u003e\n\u003cp\u003eSlow burning and smouldering fires. It works on the light scatter principle and is well suited to escape routes.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat temperature class does it carry?\u003c\/h4\u003e\n\u003cp\u003eT4 up to +60°C ambient and T5 up to +45°C ambient. The classification required on site sets the limit.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat voltage does the 55000-640APO need?\u003c\/h4\u003e\n\u003cp\u003e14 V - 22 V on a two wire, polarity sensitive supply. Check the voltage at the device on the I.S. circuit.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan a remote LED be added?\u003c\/h4\u003e\n\u003cp\u003eYes. It must be a standard high-efficiency red LED, and it needs no series resistor because current is limited to about 1 mA.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan the remote LED be controlled separately?\u003c\/h4\u003e\n\u003cp\u003eNo. It is effectively in series with the integral LED.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it connect straight to the cable?\u003c\/h4\u003e\n\u003cp\u003eNo. It connects through terminals L1 and L2 in the mounting base.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57727879479669,"sku":"55000-640APO","price":124.31,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-55000-640apo-intrinsically-safe-optical-smoke-detector-angled-view-with-address-flag.png?v=1793827467"},{"product_id":"apollo-marine-optical-smoke-detector-58000-600mar","title":"Apollo Discovery Marine Optical Smoke Detector, Addressable 58000-600MAR","description":"\u003cp\u003eThe Apollo 58000-600MAR is a Discovery marine optical smoke detector, a light scatter design for slow burning or smouldering fires. It is well suited to accommodation decks, passages and escape routes in marine installations. It is XP95, Discovery and CoreProtocol compatible, with five EN54 approved response modes.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePicks up slow fires – responds well to slow burning, smouldering fires\u003c\/li\u003e\n\u003cli\u003eSuits the routes people use – accommodation decks, passages and escape routes\u003c\/li\u003e\n\u003cli\u003eWide temperature range – -40°C to +70°C operating\u003c\/li\u003e\n\u003cli\u003eSet sensitivity at the panel – five EN54 approved response modes\u003c\/li\u003e\n\u003cli\u003eHolds its sensitivity – compensation for signal drift\u003c\/li\u003e\n\u003cli\u003eMarine approvals – MED, LR, DNV-GL, BV, ABS, CCS and KRS among others\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: two wire supply, polarity insensitive, 17 V - 28 V dc.\u003c\/li\u003e\n\u003cli\u003eMounting: connects through terminals L1 and L2 in the mounting base. 100 mm diameter x 42 mm height, 50 mm height with XPERT 7 base.\u003c\/li\u003e\n\u003cli\u003eCabling: a remote LED needing not more than 4 mA at 5 V connects between the +R and -R terminals. An earth connection terminal is also provided.\u003c\/li\u003e\n\u003cli\u003eCompatibility: XP95, Discovery and CoreProtocol compatible.\u003c\/li\u003e\n\u003cli\u003eStandards: EN 54-7, CPR, LPCB, MED, LR, DNV-GL, BV, ABS, CCS, KRS and VNIIPO.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eIs this optical smoke detector approved for marine use?\u003c\/h4\u003e\n\u003cp\u003eYes. It complies with the Marine Equipment Directive 2014\/90\/EU and carries LR, DNV-GL, BV, ABS, CCS and KRS. Check them against the vessel's requirements.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat does polarity insensitive mean?\u003c\/h4\u003e\n\u003cp\u003eThe two supply wires can go either way round. That is one less thing to check on a long run of cable.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eIs it waterproof?\u003c\/h4\u003e\n\u003cp\u003eNo. It is designed to IP44, and should be used with Deckhead Mounting Box Part No. 45681-217 if ingress protection is required.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan the panel test it remotely?\u003c\/h4\u003e\n\u003cp\u003eYes. The remote test is enabled from the panel, and the detector returns an analogue value of 85.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhich protocols does it work with?\u003c\/h4\u003e\n\u003cp\u003eXP95, Discovery and CoreProtocol. Check your panel uses one of these before ordering.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57727895601525,"sku":"58000-600MAR","price":83.53,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-58000-600mar-marine-optical-smoke-detector-angled-view-with-address-flag.jpg?v=1793827557"},{"product_id":"apollo-optical-smoke-detector-58000-600sil","title":"Apollo Discovery Optical Smoke Detector, SIL 2 Assessed 58000-600SIL","description":"\u003cp\u003eThe Apollo 58000-600SIL is a Discovery optical smoke detector assessed for use in a safety function to SIL level 2. It works on the light scatter principle, so it suits slow burning or smouldering fires, and it is well suited to bedrooms and escape routes. It is XP95 and Discovery compatible.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePicks up slow fires – responds well to slow burning, smouldering fires\u003c\/li\u003e\n\u003cli\u003eFor safety function designs – assessed and certified to SIL level 2\u003c\/li\u003e\n\u003cli\u003eSuits bedrooms and the way out – well suited for bedrooms and escape routes\u003c\/li\u003e\n\u003cli\u003eSet sensitivity at the panel – five EN 54 approved response modes\u003c\/li\u003e\n\u003cli\u003eHolds its sensitivity – compensation for signal drift\u003c\/li\u003e\n\u003cli\u003eWide temperature range – -40°C to +70°C operating\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: two wire supply, polarity insensitive, 17 V - 28 V dc.\u003c\/li\u003e\n\u003cli\u003eMounting: connects through terminals L1 and L2 in the mounting base. 100 mm diameter x 42 mm height, 50 mm height with XPERT 7 base.\u003c\/li\u003e\n\u003cli\u003eCabling: a remote LED needing not more than 4 mA at 5 V connects between the +R and -R terminals. An earth connection terminal is also provided.\u003c\/li\u003e\n\u003cli\u003eCompatibility: XP95 and Discovery compatible.\u003c\/li\u003e\n\u003cli\u003eStandards: EN 54-7 and IEC 61508 -1, 2.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat does SIL level 2 mean on a smoke detector?\u003c\/h4\u003e\n\u003cp\u003eIt is a rating for use in a safety function, assessed under the IEC 61508 standard. It matters where a safety function design calls for a set integrity level, so check with whoever holds that design.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat does polarity insensitive mean?\u003c\/h4\u003e\n\u003cp\u003eThe two supply wires can go either way round. That is one less thing to check when wiring the loop.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eIs it waterproof?\u003c\/h4\u003e\n\u003cp\u003eNo. It is designed to IP44, and should be used with Deckhead Mounting Box Part No. 45681-217 if ingress protection is required.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan the panel test it remotely?\u003c\/h4\u003e\n\u003cp\u003eYes. The remote test is enabled from the panel, and the detector returns an analogue value of 85.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhich protocols does the 58000-600SIL work with?\u003c\/h4\u003e\n\u003cp\u003eXP95 and Discovery. Check your panel uses one of these before ordering.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57727895798133,"sku":"58000-600SIL","price":86.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-58000-600sil-optical-smoke-detector-angled-view-with-address-flag.jpg?v=1793827566"},{"product_id":"apollo-flush-optical-smoke-detector-fl5100-600apo","title":"Apollo Soteria Dimension Flush Optical Smoke Detector, White FL5100-600APO","description":"\u003cp\u003eThe Apollo Soteria Dimension FL5100-600APO is a flush optical smoke detector for addressable systems where a low profile matters. It has no chamber and detects smoke just outside its housing. It has an integrated switchable isolator, is XP95, Discovery and CoreProtocol compatible, and is for internal use only.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eLow profile on the ceiling – flush mounted, with no chamber\u003c\/li\u003e\n\u003cli\u003eProtects the loop – integrated switchable isolator as standard\u003c\/li\u003e\n\u003cli\u003eHolds its sensitivity – drift compensation\u003c\/li\u003e\n\u003cli\u003eClear status at a glance – tricoloured LED status indicator\u003c\/li\u003e\n\u003cli\u003eKnows when it is blocked – proximity sensors detect physical obstructions\u003c\/li\u003e\n\u003cli\u003eHarder to remove – grub screw locking mechanism\u003c\/li\u003e\n\u003cli\u003eFaster commissioning – FasTest on CoreProtocol, with a compatible panel\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: two-wire loop, 17 V - 35 V dc, L1 and L2 polarity sensitive. Alarm current 4.5 mA.\u003c\/li\u003e\n\u003cli\u003eMounting: flush, 140 mm diameter x 38.2 mm depth, or 71 mm depth with backbox. Keep the minimum clearance of 500 mm in all directions.\u003c\/li\u003e\n\u003cli\u003eCabling: address set by an 8-way DIL switch. On mixed systems addresses 127 and 128 are reserved.\u003c\/li\u003e\n\u003cli\u003eCompatibility: XP95, Discovery and CoreProtocol compatible. Not all features may be there on an XP95 or Discovery panel.\u003c\/li\u003e\n\u003cli\u003eStandards: EN 54-7:2018, EN 54-17:2005. IP55, rating not EN 54 approved. For internal use only.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow does a smoke detector with no chamber work?\u003c\/h4\u003e\n\u003cp\u003eAn IR LED emits light outside the detector, and smoke scatters it back to a photo-diode. Two photo-diodes and three IR emitters are used in combination, which also picks up obstructions.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it work on an XP95 or Discovery panel?\u003c\/h4\u003e\n\u003cp\u003eYes. It is designed to operate on XP95 and Discovery loops, though not all features may be there. XP95 panels with drift compensation algorithms must have them disabled for these detectors.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhy does the label have to stay on until commissioning?\u003c\/h4\u003e\n\u003cp\u003eIt aids installation, shields from dust and protects the lenses. It must only come off at commissioning, because leaving it on reports a fault to the panel.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow is it tested?\u003c\/h4\u003e\n\u003cp\u003eThe preferred method uses a Solo 365 with a special Solo 367 adapter. Clean the detector afterwards with a dry lint-free cloth.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it be used outdoors?\u003c\/h4\u003e\n\u003cp\u003eNo. It is for internal use only.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow much clearance does it need?\u003c\/h4\u003e\n\u003cp\u003eA minimum of 500 mm in all directions, with the backbox arrow towards the longest clear line of sight.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57727905530229,"sku":"FL5100-600APO","price":197.67,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-fl5100-600apo-flush-optical-smoke-detector-front-view.png?v=1793827963"},{"product_id":"apollo-marine-optical-smoke-detector-orb-op-42001-mar","title":"Apollo Orbis Marine Optical Smoke Detector, Conventional ORB-OP-42001-MAR","description":"\u003cp\u003eThe Apollo ORB-OP-42001-MAR is an Orbis marine optical smoke detector for conventional fire circuits. It is a general purpose detector, recommended for early warning of fires in most areas, with improved sensitivity to black smoke. It runs on 8.5 V dc to 33 V dc and operates from -40°C to +70°C.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eBetter on dark smoke – good in black as well as white smoke\u003c\/li\u003e\n\u003cli\u003eChecks before it alarms – extra confirmation of smoke before any alarm signal\u003c\/li\u003e\n\u003cli\u003eFewer false alarms – designed to reduce over-sensitivity to transient phenomena\u003c\/li\u003e\n\u003cli\u003eHolds its sensitivity – compensation for slow changes in sensitivity\u003c\/li\u003e\n\u003cli\u003eWide temperature range – -40°C to +70°C operating and storage\u003c\/li\u003e\n\u003cli\u003eQuick to test – FasTest takes just four seconds\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: two wire supply, polarity sensitive, 8.5 V dc to 33 V dc. Alarm current 20 mA at 12 V, 40 mA at 24V.\u003c\/li\u003e\n\u003cli\u003eMounting: 97 mm diameter x 31 mm height, or 100 mm diameter x 46 mm height in base.\u003c\/li\u003e\n\u003cli\u003eCabling: maximum polarity reversal 200 ms. Remote output 1.2 kΩ connected to negative supply.\u003c\/li\u003e\n\u003cli\u003eStandards: EN54-7, MED, LR, BV, ABS and CCS. Designed to IP23D.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat fires does an Orbis marine optical detector suit?\u003c\/h4\u003e\n\u003cp\u003eA wide spectrum of fires. Optical detectors are regarded as particularly suitable for smouldering fires and escape routes, and this one also performs well in black smoke.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eIs this smoke detector approved for marine use?\u003c\/h4\u003e\n\u003cp\u003eYes. It complies with the Marine Equipment Directive 2014\/90\/EU and carries LR, BV, ABS and CCS. Check them against the vessel's requirements.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes the ORB-OP-42001-MAR have a flashing LED?\u003c\/h4\u003e\n\u003cp\u003eNo. The flashing LED version has its own part number, ORB-OP-42003-MAR.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat panels can it work with?\u003c\/h4\u003e\n\u003cp\u003eConventional circuits that suit its 8.5 V dc to 33 V dc supply and 600 Ω alarm load. Check these figures against the panel's documentation.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat does the yellow LED show?\u003c\/h4\u003e\n\u003cp\u003eDirtAlert shows the drift compensation limit has been reached, and SensAlert shows the sensor is not operating correctly.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57727910805877,"sku":"ORB-OP-42001-MAR","price":39.58,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-orb-op-42001-mar-marine-optical-smoke-detector-angled-view-in-base.jpg?v=1793828202"},{"product_id":"apollo-intrinsically-safe-optical-smoke-detector-orb-op-52028-apo","title":"Apollo Orbis I.S. Optical Smoke Detector, Flashing LED ORB-OP-52028-APO","description":"\u003cp\u003eThe Apollo ORB-OP-52028-APO is an Orbis I.S. optical smoke detector with a flashing LED, for intrinsically safe conventional circuits. It is a general purpose detector, recommended for early warning of fires in most areas, with improved sensitivity to black smoke. It runs on 14.8 V dc to 28 V dc and holds ATEX approval.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eShows it is alive – the red LED flashes every four seconds in normal operation\u003c\/li\u003e\n\u003cli\u003eBetter on dark smoke – improved sensitivity to black smoke\u003c\/li\u003e\n\u003cli\u003eChecks before it alarms – extra confirmation of smoke before any alarm signal\u003c\/li\u003e\n\u003cli\u003eHolds its sensitivity – compensation for slow changes in sensitivity\u003c\/li\u003e\n\u003cli\u003eFor hazardous sites – Ex ia IIC T5, with T4 up to 60°C\u003c\/li\u003e\n\u003cli\u003eLow standby load – 85 µA average quiescent current at 24 V\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: two wire supply, polarity sensitive, 14.8 V dc to 28 V dc. Polarity reversal is not allowed.\u003c\/li\u003e\n\u003cli\u003eMounting: terminals and connections must be protected to at least IP20 with the detector in the base. 100 mm diameter x 50 mm height in base.\u003c\/li\u003e\n\u003cli\u003eCabling: up to 20 Orbis I.S. detectors on a single barrier circuit, and not more than one hazardous area circuit on any one safety barrier.\u003c\/li\u003e\n\u003cli\u003eCompatibility: alarm load 325 Ω in series with a 1.0 V drop, so check that it suits the panel.\u003c\/li\u003e\n\u003cli\u003eStandards: EN54-7, CPR, LPCB, MED, IECEx, ATEX and others, certificate BASEEFA06ATEX0007X.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat does the flashing LED do?\u003c\/h4\u003e\n\u003cp\u003eIt flashes red every four seconds in normal operation, at the end of FasTest. The version without it is Part No. ORB-OP-52027-APO.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat sort of fire does this optical smoke detector suit?\u003c\/h4\u003e\n\u003cp\u003eA wide spectrum of fires. Optical detectors are regarded as particularly suitable for smouldering fires and escape routes.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat temperature limits apply in a hazardous area?\u003c\/h4\u003e\n\u003cp\u003eClass T5 is -40°C to +45°C and class T4 is -40°C to +60°C. The intrinsic safety gas classification restricts the operating temperature.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow many can go on one barrier circuit?\u003c\/h4\u003e\n\u003cp\u003eUp to 20 Orbis I.S. detectors, subject to the voltage at each detector staying above the specified minimum.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWho should design the I.S. system?\u003c\/h4\u003e\n\u003cp\u003eOnly engineers familiar with the codes of practice for detection systems and hazardous area electrical systems.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57727910871413,"sku":"ORB-OP-52028-APO","price":81.46,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-orb-op-52028-apo-intrinsically-safe-optical-smoke-detector-angled-view-in-base.jpg?v=1793828218"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/collections\/apollo_55000-600apo.png?v=1747058463","url":"https:\/\/wmestore.co.uk\/collections\/apollo-smoke-detectors.oembed?page=2","provider":"WME","version":"1.0","type":"link"}