{"product_id":"apollo-mains-switching-input-output-unit-sa4700-103apo","title":"Apollo Intelligent Mains Switching Input\/Output Unit, Fire Alarm Interface SA4700-103APO","description":"\u003cp\u003eThe Apollo SA4700-103APO is a fire alarm interface for monitoring contacts and switching mains from an addressable loop. It suits installers linking a fire system to other equipment. It has two input channels and a relay rated 5 A at 30 V dc or 250 V ac, with XP95, Discovery and CoreProtocol compatibility.\u003c\/p\u003e\u003ch2\u003eKey features\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eSwitches mains directly – a voltage free change over relay output capable of switching mains\u003c\/li\u003e\n\u003cli\u003eWatches two things at once – two input channels\u003c\/li\u003e\n\u003cli\u003eActs if the loop is lost – Failsafe mode activates the relay on loss of loop or protocol loss\u003c\/li\u003e\n\u003cli\u003eShows what is happening – status LEDs for relay, polling, isolator and inputs\u003c\/li\u003e\n\u003cli\u003eQuicker to wire – improved design for ease of wiring meaning faster installation\u003c\/li\u003e\n\u003cli\u003eMore options on CoreProtocol – nine pre-configured modes and earth fault monitoring, on CoreProtocol enabled systems only\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch2\u003eFor installers\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003ePower: loop powered, 17–35 V dc. Quiescent current 700 µA, max current with LEDs on 5.2 mA.\u003c\/li\u003e\n\u003cli\u003eMounting: surface with the supplied back-box, or flush using a UK double gang back-box of minimum depth 30mm. 60 mm height x 150 mm width x 90 mm depth.\u003c\/li\u003e\n\u003cli\u003eCabling: relay contact rating 5 A at 30 V dc or 250 V ac. Inputs use a 20k end-of-line resistor and 1k input trigger resistor.\u003c\/li\u003e\n\u003cli\u003eCompatibility: XP95, Discovery and CoreProtocol compatible, fire control panel dependant. It behaves as XP95 on XP95\/Discovery and as Soteria on CoreProtocol.\u003c\/li\u003e\n\u003cli\u003eStandards: EN 54-17, EN 54-18, CPR, LPCB, VdS, BOSEC, SBSC, FG. IP54.\u003c\/li\u003e\n\u003c\/ul\u003e\u003cdiv class=\"mt-6\"\u003e\n\u003ch3\u003eFrequently asked questions\u003c\/h3\u003e\n\u003ch4 class=\"product-description-title\"\u003eCan it switch mains voltage?\u003c\/h4\u003e\n\u003cp\u003eYes. The relay contacts are rated 5 A at 30 V dc or 250 V ac, and they are voltage free.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eWhat happens if the loop fails?\u003c\/h4\u003e\n\u003cp\u003eIn Failsafe mode the relay activates without being commanded by the control panel, on loss of loop or protocol loss. Failsafe mode is selected with a DIL switch.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eDoes it work on XP95 and Discovery panels?\u003c\/h4\u003e\n\u003cp\u003eYes, behaving as an XP95 device, depending on the fire control panel. Several features, including the controllable isolator, are for CoreProtocol enabled systems only.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eIs a back box included?\u003c\/h4\u003e\n\u003cp\u003eYes. Surface mounting uses the supplied back-box. Flush mounting needs a UK double gang back-box of minimum depth 30mm.\u003c\/p\u003e\n\u003ch4 class=\"product-description-title\"\u003eHow much loop load does it add?\u003c\/h4\u003e\n\u003cp\u003eIt has an Equivalent Detector Load of 2. The maximum load for a node is an EDL of 20.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Apollo Fire","offers":[{"title":"Default Title","offer_id":57711101903221,"sku":"SA4700-103APO","price":67.22,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/apollo-sa4700-103apo-mains-switching-input-output-unit-angled-view-with-back-box.png?v=1793620993","url":"https:\/\/wmestore.co.uk\/products\/apollo-mains-switching-input-output-unit-sa4700-103apo","provider":"WME","version":"1.0","type":"link"}