{"product_id":"eaton-ups-9px3000irtbph","title":"Eaton 9PX3000IRTBPH 3000VA\/3000W Hardwired UPS, 3U Rack and Tower","description":"\u003cp\u003e\u003cstrong\u003ePlease note: this is a non-returnable item (excluding faulty goods)\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eThe Eaton 9PX3000IRTBPH is a 3000 VA \/ 3000 W single-phase uninterruptible power supply from the 9PX line, supplied as a 3U rack-or-tower chassis with a hardwired connection and a maintenance bypass supplied with it.\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eThis is the hardwired member of the 9PX 3000 family. Instead of terminating in IEC outlets, the 9PX3000IRTBPH is wired directly into the installation. That is what a fixed distribution board, a rack tail or a plant room panel usually wants, and what a plug-and-socket model cannot give you.\u003c\/p\u003e\u003cp\u003eIt is a single-phase unit. It carries a maintenance bypass in the box, so the UPS can be taken out of circuit for service without dropping the load. The chassis is 3U and converts between rack and tower, so the same unit suits a comms cabinet and a floor-standing position in a riser or a plant room.\u003c\/p\u003e\u003cp\u003eBrackets for 19-inch mounting, a rack-mounting kit and tower supports are all supplied. Internally it runs six sealed lead acid (VRLA) batteries of 9.0 Ah. It weighs 27.41 kg, so plan the lift and the shelf.\u003c\/p\u003e\u003ch3\u003eKey features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRated capacity:\u003c\/strong\u003e 3000 VA and 3000 W, so the volt-amp and watt figures do not diverge the way they do on older UPS designs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHardwired connection:\u003c\/strong\u003e This variant terminates in a single hardwired connection rather than a bank of IEC sockets. That is why it is specified where the load is wired into fixed distribution.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance bypass supplied:\u003c\/strong\u003e A maintenance bypass is supplied with the unit, so the UPS can be isolated for service or battery work without taking the connected load down.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRack or tower, 3U:\u003c\/strong\u003e The chassis is a 3U rack-or-tower design measuring 44.0 cm wide, 13.0 cm high and 48.5 cm deep, and both 19-inch mounting brackets and tower supports are in the box.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBattery configuration:\u003c\/strong\u003e Six sealed lead acid (VRLA) batteries of 9.0 Ah, a chemistry and count worth knowing before you plan a replacement cycle or a battery disposal route.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWhat is in the box:\u003c\/strong\u003e Supplied with the UPS: a maintenance bypass, an input cable, a cable locking system, a rack-mounting kit and two 19-inch mounting brackets. Also two tower supports, a serial cable, a USB cable, safety instructions and a quick-start guide.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight and handling:\u003c\/strong\u003e 27.41 kg, so it is a two-person lift into a cabinet and the shelf or rails need to be rated accordingly.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWarranty:\u003c\/strong\u003e Eaton's datasheet for this catalogue number lists three years on the electronics and two years on the battery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCompliance:\u003c\/strong\u003e CE marked, RoHS compliant and WEEE compliant.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eUse cases\u003c\/h3\u003e\u003cp\u003eA hardwired 3 kVA UPS lands in a specific set of places. The first is a comms room or riser where the cabinet load is fed from a local distribution board rather than a socket strip. The electrician wants a fixed connection with a proper isolator either side.\u003c\/p\u003e\u003cp\u003eThe second is plant and controls: a BMS panel, an access control head end, a fire alarm or CCTV headend cabinet, or a small process controller. These are loads that must not blink, where a plug is the wrong answer because a plug can be pulled. The third is a small edge or branch installation where a single 3U unit has to protect everything in one cabinet and then convert to tower when the cabinet is later removed.\u003c\/p\u003e\u003cp\u003eThe maintenance bypass is the part that decides many specifications. On a system nobody is allowed to shut down, taking the UPS out of circuit for a battery change without an outage is worth more than any headline efficiency figure. Plan the installation with a competent electrician, size the runtime against the actual connected load rather than the nameplate, and agree the battery replacement interval at handover rather than discovering it four years later.\u003c\/p\u003e","brand":"Eaton","offers":[{"title":"Default Title","offer_id":57520828285301,"sku":"9PX3000IRTBPH","price":4439.96,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/9PX3000IRTBPH.jpg?v=1787644186","url":"https:\/\/wmestore.co.uk\/products\/eaton-ups-9px3000irtbph","provider":"WME","version":"1.0","type":"link"}