{"product_id":"mag-fire-alarm-panels-magpro16","title":"MAG MAGPRO16 Addressable 16 Zone Fire Panel","description":"\u003cp\u003eThe MAG MAGPRO16 is an Addressable 16 Zone Fire Panel. Featuring addressable operation, it is built for dependable professional installation.\u003c\/p\u003e\n\u003ch5\u003eKey Features\u003c\/h5\u003e\n\u003cul\u003e\n  \u003cli\u003e16 zones\u003c\/li\u003e\n  \u003cli\u003eMaximum 250 devices per loop\u003c\/li\u003e\n  \u003cli\u003eMemory log: 10,000 events\u003c\/li\u003e\n  \u003cli\u003eNetworkable up to 64 panels\u003c\/li\u003e\n  \u003cli\u003eAddressable operation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eIn Detail\u003c\/h5\u003e\n\u003cp\u003eSpecified across commercial, industrial and multi-occupancy premises, ESP's fire alarm panel products are engineered for reliable life-safety performance and straightforward installation by qualified engineers. Robust construction and clear indication help ensure the system performs when it matters.\u003c\/p\u003e\n\u003cp\u003eA dependable fire alarm system relies on quality components working together, and this unit integrates cleanly with ESP panels, detectors and sounders — a well-supported platform to design around and maintain.\u003c\/p\u003e\n\u003cp\u003eThe MAG MAGPRO16 is a practical choice wherever a reliable fire alarm panel is required, supplied with full WME trade support and free UK delivery on orders over £129.\u003c\/p\u003e\n\u003ch5\u003eTechnical Specifications\u003c\/h5\u003e\u003ctable\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMAG\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMAGPRO16\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e306 x 412 x 81.2\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Number of Events in Log\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10240\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eVolume Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 (Low \u0026amp; High)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDevice Loading Units (DLU's) - Low\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWarranty (Years)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage (Mains Powered Panel)(V DC)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25.5 - 35\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandby Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 12V 17Ah (Battery Calculation Required)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePSU Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.7A\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLoops\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAuxiliary Output\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1; 24V DC @ 500mA\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUnmonitored Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 (24VDC@15A)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound Output @ 1m (Low) (db)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65+\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound Output @ 1m (High) (db)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e85+\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommunication Protocol\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClosed Protocol\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocol Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCustom (Closed)\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Communication Range (m)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDependant on Loop Calculation\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature (°C)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-5 to +40\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGTIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5060224104842\u003c\/td\u003e\n\u003c\/tr\u003e\n  \u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCommodity Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8531103000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch5\u003eDownloads\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/MAGPRO16-tech-sheet.pdf?v=1784562904\" target=\"_blank\" rel=\"noopener\"\u003eTech Sheet (PDF)\u003c\/a\u003e\u003c\/p\u003e","brand":"ESP","offers":[{"title":"Default Title","offer_id":57368145527157,"sku":"MAGPRO16","price":425.45,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0050\/1216\/0612\/files\/mag-fire-alarm-panels-magpro16.png?v=1784500565","url":"https:\/\/wmestore.co.uk\/products\/mag-fire-alarm-panels-magpro16","provider":"WME","version":"1.0","type":"link"}