Advanced
Advanced MXP-567 Advanced-MXP-567
The Advanced loop driver card allows the expansion of an additional loop for a MxPro 5 panel providing the panel has capacity.
The Loop Driver Card MXP-567 can be used with the Nittan
protocol.
For use with MxPro 5 analogue addressable panels
Advanced MXP-503 Advanced-MXP-503
The Ad-NeT network system allows all MxPro 5 series control
panels, remote terminals and network peripherals to be
connected together using standard fire resistant two-core cable.
It provides both the benefits of distributed intelligence and
reduced installation costs whilst catering for the smallest
two-panel network through to the largest 200-panel wide area
networked system.
The network operates as a true peer-to-peer system allowing
information from any input or output device to be passed over
the network and displayed on any MxPro 5 control panel or
remote terminal as required.
Simply adding and connecting a network card allows any MxPro
5 control panel or remote terminal to be networked. All other
nodes on the Ad-NeT system will be instantly aware of a panel
as soon as it is given a valid network node address, allowing
additional panels to be added at any time. All panels incorporate
a network analyser providing valuable diagnostic and status
information and also have the facility to prevent the transmission
of fires or faults during commissioning.
For more complex systems, the Windows-based PC-NeT Mx
configuration software allows sector based programming for
Mute, Silence, Resound and Reset control keys as well as
investigation delays, group disablement and test instructions. All
panels within the same sector will share common controls and
each panel or remote terminal can also be programmed to show
specific network information on a zonal basis. For cause and
effect, any input device can be programmed to operate any
output device on any pane
Advanced MXP-502 Advanced-MXP-502
The Loop Driver Card is designed for use with the MxPro 5 range of analogue addressable panels. It provides control and connection to detector loops.
The Loop Driver Card Mxp-502 can be used with Apollo, Hochiki
or Argus Vega protocols
Advanced MXM-503 Advanced-MXM-503
All bezels are provided complete with fitting kit for a quick and
easy solution for semi-recessing the MxPro 5 series control
panels.
Please note: when recessing, extra clearance (5mm all sides)
must be factored to allow the bezel to be fitted to the backbox.
MXM-503 Semi-Flushing Bezel – Mx-5000 large enclosure
475mm(H) x 450mm (W) 30mm 105mm
Advanced MXM-502 Advanced-MXM-502
All bezels are provided complete with fitting kit for a quick and
easy solution for semi-recessing the MxPro 5 series control
panels.
Please note: when recessing, extra clearance (5mm all sides)
must be factored to allow the bezel to be fitted to the backbox.
Mxm-502 Semi-Flushing Bezel – Mx-5000 medium enclosure
345mm (H) x 430mm (W) 30mm 105mm
Advanced MXM-501 Advanced-MXM-501
All bezels are provided complete with fitting kit for a quick and
easy solution for semi-recessing the MxPro 5 series control
panels.
Please note: when recessing, extra clearance (5mm all sides)
must be factored to allow the bezel to be fitted to the backbox.
Mxm-501 Semi-Flushing Bezel – Mx-5000 small enclosure
345mm (H) x 345mm (W) 30mm 70mm
Advanced MX-5401N Advanced-MX-5401N
Nittan Evolution Protocol
1-4 loop addressable fire control panel c/w 1 loop card in large enclosure
Up to 254 devices per loop (protocol dependent)
Up to 200,000 devices per network
Networkable up to 200 nodes
Built in voltage and current meters
On board or optional remote battery temperature sensor
Advanced’s simple select and click programming and configuration
Quick start and protect – A working system after an Auto learn is performed
20 built-in, fully programmable LEDs
5000 event log entries
201 programmable false alarm management areas per panel
Timed enablement of isolated zones, input and output devices
Backward compatible with MxPro 4 network
Approved to EN54 Parts 2, 4 and 13
Certified by FM Approvals to EN54 Parts 2 and 4
Autolearn and Loop detection
Up to 2000 fire detection zones
True peer-to-peer networking
Supports intelligent/programmable remote terminals, BMS interface, IP Gateway and I/O Drivers
Circuit monitoring from any panel or repeater
Direct USB and RS232 PC connections
Peripheral expansion built in
4 programmable push buttons
Complete device history from each panel
Programmable screen logo
Advanced logic delivering huge configuration opportunities
Advanced MX-5401 Advanced-MX-5401
Apollo/Hochiki Protocol
1-4 loop addressable fire control panel c/w 1 loop card in large enclosure
Up to 254 devices per loop (protocol dependent)
Up to 200,000 devices per network
Networkable up to 200 nodes
Built in voltage and current meters
On board or optional remote battery temperature sensor
Advanced’s simple select and click programming and configuration
Quick start and protect – A working system after an Auto learn is performed
20 built-in, fully programmable LEDs
5000 event log entries
201 programmable false alarm management areas per panel
Timed enablement of isolated zones, input and output devices
Backward compatible with MxPro 4 network
Approved to EN54 Parts 2, 4 and 13
Certified by FM Approvals to EN54 Parts 2 and 4
Autolearn and Loop detection
Up to 2000 fire detection zones
True peer-to-peer networking
Supports intelligent/programmable remote terminals, BMS interface, IP Gateway and I/O Drivers
Circuit monitoring from any panel or repeater
Direct USB and RS232 PC connections
Peripheral expansion built in
4 programmable push buttons
Complete device history from each panel
Programmable screen logo
Advanced logic delivering huge configuration opportunities
Advanced MX-5201N Advanced-MX-5201N
Nittan Evolution Protocol
1-2 loop addressable fire control panel c/w 1 loop card in medium enclosure
Up to 254 devices per loop (protocol dependent)
Up to 200,000 devices per network
Networkable up to 200 nodes
Built in voltage and current meters
On board or optional remote battery temperature sensor
Advanced’s simple select and click programming and configuration
Quick start and protect – A working system after an Auto learn is performed
20 built-in, fully programmable LEDs
5000 event log entries
201 programmable false alarm management areas per panel
Timed enablement of isolated zones, input and output devices
Backward compatible with MxPro 4 network
Approved to EN54 Parts 2, 4 and 13
Certified by FM Approvals to EN54 Parts 2 and 4
Autolearn and Loop detection
Up to 2000 fire detection zones
True peer-to-peer networking
Supports intelligent/programmable remote terminals, BMS interface, IP Gateway and I/O Drivers
Circuit monitoring from any panel or repeater
Direct USB and RS232 PC connections
Peripheral expansion built in
4 programmable push buttons
Complete device history from each panel
Programmable screen logo
Advanced logic delivering huge configuration opportunities
Advanced MX-5201 Advanced-MX-5201
Apollo/Hochiki Protocol
1-2 loop addressable fire control panel c/w 1 loop card in medium enclosure
Up to 254 devices per loop (protocol dependent)
Up to 200,000 devices per network
Networkable up to 200 nodes
Built in voltage and current meters
On board or optional remote battery temperature sensor
Advanced’s simple select and click programming and configuration
Quick start and protect – A working system after an Auto learn is performed
20 built-in, fully programmable LEDs
5000 event log entries
201 programmable false alarm management areas per panel
Timed enablement of isolated zones, input and output devices
Backward compatible with MxPro 4 network
Approved to EN54 Parts 2, 4 and 13
Certified by FM Approvals to EN54 Parts 2 and 4
Autolearn and Loop detection
Up to 2000 fire detection zones
True peer-to-peer networking
Supports intelligent/programmable remote terminals, BMS interface, IP Gateway and I/O Drivers
Circuit monitoring from any panel or repeater
Direct USB and RS232 PC connections
Peripheral expansion built in
4 programmable push buttons
Complete device history from each panel
Programmable screen logo
Advanced logic delivering huge configuration opportunities
Advanced MX-5101N Advanced-MX-5101N
Nittan Evolution Protocol
1 loop addressable fire control panel in small enclosure
Up to 254 devices per loop (protocol dependent)
Up to 200,000 devices per network
Networkable up to 200 nodes
Built in voltage and current meters
On board or optional remote battery temperature sensor
Advanced’s simple select and click programming and configuration
Quick start and protect – A working system after an Auto learn is performed
20 built-in, fully programmable LEDs
5000 event log entries
201 programmable false alarm management areas per panel
Timed enablement of isolated zones, input and output devices
Backward compatible with MxPro 4 network
Approved to EN54 Parts 2, 4 and 13
Certified by FM Approvals to EN54 Parts 2 and 4
Autolearn and Loop detection
Up to 2000 fire detection zones
True peer-to-peer networking
Supports intelligent/programmable remote terminals, BMS interface, IP Gateway and I/O Drivers
Circuit monitoring from any panel or repeater
Direct USB and RS232 PC connections
Peripheral expansion built in
4 programmable push buttons
Complete device history from each panel
Programmable screen logo
Advanced logic delivering huge configuration opportunities
Advanced MX-5101 Advanced-MX-5101
- 20 programmable Zonal / 25 System LEDs.
- Apollo, Argus Vega, Hochiki & Nittan Evolution protocol support.
- Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full
- EN54 compliance without additional hardware.
- Dedicated USB & RS232 Serial Port for direct PC or modem connection.
- Installer friendly Auto-learn, Loop Detection and On-board Scope facility.
- Graphical display configurable for virtually any language.
- Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination.
- Integral P-Bus for system expansion via available option cards.
- Ad-NeT peer-to-peer network with up to 2000 zones
- Approved to BS EN54 part 2, 4 and 13
Advanced MX-5020 Advanced-MX-5020
MxPro 5 Remote Control Terminal – Standard Network
Includes built-in standard network card
The RCT has additional sector based control keys for Silence, Mute, Resound and Reset, which allows other networked panels to selectively respond to controls as programmed. E.g. on a site with multiple buildings, a user may be allowed to silence and reset fires originating in their own building. Fires originating from other buildings are displayed but cannot be reset.
Fully on-site programmable via onboard alphanumeric keypad or PC configuration tools
View all information from across the network
By using flash memory and an advanced graphical display, the remote terminals can be easily configured to operate in virtually any language, with any character set and allows for the installer’s logo and company details to be displayed on the LCD during normal operation
Networked for system display or control
Programmable switch input
> Graphical LCD display
> Ad-NeT/Ad-Net+ compatible
> Slide-in labels
> Small, robust and compact
> 24V DC operating voltage
> 3-year warranty
> Disable/enable options
Advanced MX-5010 Advanced-MX-5010
MxPro 5 Remote Display Terminal – Standard Network
Includes built-in standard network card
The RDT has additional control keys for Mute which allows other network panels’ warning buzzer to be muted
Fully on-site programmable via onboard alphanumeric keypad or PC configuration tools
View all information from across the network
By using flash memory and an advanced graphical display, the remote terminals can be easily configured to operate in virtually any language, with any character set and allows for the installer’s logo and company details to be displayed on the LCD during normal operation
Networked for system display or control
Programmable switch input
Graphical LCD display
Ad-NeT/Ad-Net+ compatible
Slide-in labels
Small, robust and compact
24V DC operating voltage
3-year warranty
Disable/enable options