SYC Protective cover for fire call points BF370SC

SKU: BF370SC

C-Tec BF370SC Protective Cover for Sycall Fire Call Points

The BF370SC is a protective cover for Sycall Fire Call Points.

 

£3.90EX VAT
Add to Cart

CA Detector base CA408

SKU: CA408
C-TEC CA408 CAST BASE PLATE
 
The C-Tec CA408 is a detector base designed for use with the C-Tec CAST protocol range of analogue addressable fire alarm system detectors. 
 
Features
 
Compatible with C-TEC’s entire range of CAST addressable detectors.
Third-party LPCB certified to the relevant parts of EN54 in conjunction with our CAST detectors.
Easy to fit with lots of working space.
Can be ceiling mounted in any orientation due to the true 360° degree viewing angle of the LED indicator strips on all CAST detectors.
Integrated detector/base locking mechanism, head removal tool and ID tag.
Simple ‘click and twist’ design.
Also compatible with many of C-TEC’s CAST protocol sounder VADs.
Remote LED terminals for the optional connection to a BF318 Remote indicator.
Optional CA408R relay base also available.
£3.90EX VAT
Add to Cart

CA Programmable Multisensor Detector CA414

SKU: CA414
C-TEC CA414 CAST MULTISENSOR DETECTOR
 
The C-Tec CA414 is a CAST protocol programmable analogue addressable multisensor detector for use on the C-Tec CAST protocol range of fire alarm system equipment.
 
Features
 
A high-quality programmable multi-sensor fire detector for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
LPCB certified to EN54-5, 7 & 17 and CEA 4021. Also Kiwa Telefication certified to EN54-13.
Onboard programmable heat & smoke sensors make it deal for detecting a wide range of fires whilst also reducing false alarms.
Multiple sensitivity/sensor settings.
Smart algorithms help reduce false alarms.
Drift compensation functionality.
Short circuit loop isolator.
Includes two 8mm x 2mm ultra-bright red LED indicating strips.
Different sensitivities can be selected for different times of the day (day/night, building occupied/unoccupied etc).
5mA typical alarm current (370uA typical quiescent current) @ 22-40V DC.
Programmable multi-function status LED.
Compatible with C-TEC’s CA408 CAST base c/w integrated locking mechanism & ID tag.

 

£28.90EX VAT
Add to Cart

CA Optical Smoke Detector CA416

SKU: CA416
C-TEC CA416 CAST OPTICAL SMOKE DETECTOR
 
The C-Tec CA416 is a CAST protocol analogue addressable optical smoke detector for use on the C-Tec CAST protocol range of fire alarm system equipment.
 
Features
 
A high-quality smoke detector for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
LPCB certified to EN54-7 & 17 and Kiwa Telefication certified to EN54-13.
Smart algorithms help reduce false alarms.
Onboard short circuit loop isolator.
Includes two 8mm x 2mm ultra-bright red LED indicating strips.
Drift compensation functionality.
0.16dB/m sensitivity/obscuration level.
5mA typical alarm current (370uA typical quiescent) @ 22-40V DC
Programmable multi-function status LED.
Compatible with C-TEC’s CA408 CAST base c/w integrated locking mechanism & ID tag.
£23.90EX VAT
Add to Cart

CA Programmable Heat detector CA402

SKU: CA402
  • A high quality programmable heat detector for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
  • LPCB certified to EN54-5 & 17 and Kiwa Telefication certified to EN54-13.
  • Can be programmed to operate as a Class A1R (rate of rise), Class A2 (64ºC fixed temperature) or Class B (76ºC fixed temperature) heat detector. Default setting is A2.
  • Onboard short circuit loop isolator.
  • Includes two 8mm x 2mm ultra-bright red LED indicating strips.
  • Different sensitivities can be selected for different times of the day (day/night, building occupied/unoccupied etc).
  • 5mA typical alarm current (370uA typical quiescent) @ 22-40V DC.
  • Programmable multi-function status LED.
  • Compatible with C-TEC’s CA408 CAST base c/w integrated locking mechanism & ID tag.
£22.90EX VAT
Add to Cart

CA Universal Manual call point RED CA470

SKU: CA470
  • A high-quality red manual call point for use with C-TEC’s XFP & ZFP ‘CAST’ protocol Addressable Fire Panels.
  • LPCB certified to EN54 Parts 11 & 17 and Kiwa Telefication certified to EN54-13.
  • Surface or flush mountable.
  • Onboard short-circuit loop isolator.
  • Smooth-action resettable element mimics the feel of breaking glass.
  • Supplied with reset/back box removal key and ‘Not in Use’ label.
  • Red LED ‘alarm ring’ illuminates call point face upon activation.
  • Photoluminescent operating window remains visible for up to 5 minutes.
  • 5mA typical alarm current (370µA typical quiescent @ 22-40V DC.
  • IP42 rated (IP67 rated version also available, order code CA47067)
  • Yellow, green, blue and white versions also available.
£24.90EX VAT
Add to Cart

XFP 2 loop 32Z CAST

SKU: XFP502/CA

C-TEC XFP502/CA XFP 2 loop 32 Zone Panel, C-TEC CAST. Max. 2 x 7Ah batteries

C-TEC’s tried and trusted XFP two loop 32 zone addressable fire alarm panel – now available with C-TEC’s own digital fire alarm system protocol, CAST and fully certified to EN54 parts 2, 4 & 13.

With two powerful 40V 450mA loop drivers allowing the connection of up to 255 CAST devices per loop, the installation of a robust, feature-packed addressable fire alarm system has never been easier.

Protocol Features

‘CAST’ is the world’s most-advanced ‘distributed intelligence’ fire alarm system protocol. Conceived, designed and realised by C-TEC as part of a five-year, multi-million pound project, it involved the creation of a powerful proprietary communication protocol (C-TEC Addressable System Technology, CAST) and multiple control panels & field devices. Key features include:

• 255 devices per loop.

• Autonomous decision-making for faster response times.

• Multiple type codes.

• 40V loop drive voltage.

• Two ‘soft’ addressing options – automatic via the panel or manual via a powerful handheld programmer.

• Powerful multi-level addressing facilitates easy device addition and swapped device identification.

• Multiple functionality at a single address (integrated devices) – due 2021.

• Volumes, tones & detector modes can be changed at compatible panels.

• High-speed data transmission and robust data transfer.

• Provides geographical location of short and open circuit faults (a short circuit isolator is included as standard in every CAST field device).

• Replace device function.

• Programmable multi-function status LED.

• Future seamless integration with other CAST life safety systems reducing energy, servicing, installation and repair costs.

• ENVISION Enabled – fully compliant with our new ENVISION Cloud-based Fire ‘IoT’ Remote Access, System Test and Site Management software package.

• Designed and manufactured in the UK.

Panel Features

• Certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB) and EN54-13 by Kiwa Telefication.

• Two independently programmable conventional sounder circuits.

• Two programmable inputs.

• A fault output relay and three programmable relay outputs with voltage free changeover contacts.

• A selection of zone dependency/coincidence functions.

• A day/night (building occupied/unoccupied) function.

• An investigation delay period function.

• Phased evacuation facility.

• An alarm counter that records how many times the panel has been in alarm state.

• Powerful short circuit protected loop drivers.

• An integral EN54-4/A2 switch mode.

• Adjustable contamination levels.

• Earth fault monitoring.

• Combined keypad / keyswitch entry to Access Levels 2 and 3.

• 500 event monitoring.

• An intuitive Windows based upload-download PC program.

• Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.

 

£576.90EX VAT
Add to Cart

CFP ECO 8 zone panel CFP708E-4

SKU: CFP708E-4
  • Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
  •  

  • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
  •  

  • Manufactured by C-TEC in the UK.
  •  

  • Two detector zone circuits.
  •  

  • Four conventional sounder circuits
  •  

  • Integral 1.5A EN54-4/A2 compliant switch mode PSU.
  •  

  • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
  •  

  • Two on-board relays (Fire and Fault).
  •  

  • Two open-collector outputs (Remote and Reset).
  •  

  • ‘Class change’ and alert inputs.
  •  

  • Installer-friendly design.
  •  

  • Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
  •  

  • Low 25mA quiescent current.
  •  

  • Multiple indicators.
  •  

  • System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
  •  

  • Space for two x 12V 3.3Ah VRLA batteries.
  •  

  • Fully compatible with C-TEC’s ActiV range of conventional fire detectors.
£159.90EX VAT
Add to Cart

CA Input output module CA730

SKU: CA730
  • LPCB certified to EN54-17 & 18 and Kiwa Telefication certified to EN54-13.

  • Incorporates the functions of a switch monitor, zone monitor and output unit.

  • Can be configured to monitor any combination of:-

    • Up to 20 conventional detectors & 10 MCPs

    • Any normally open switch with an EOL resistor fitted.

    • A simple normally open or closed switch (non-fault monitored).

  • Onboard short-circuit loop isolator.

  • 5.5mA typical alarm current (1.3mA typical quiescent current) @ 22-40V DC.

  • Indicators for Loop polling, input faults and relay status.

  • Can switch 1A@30V DC (or 0.3A@125V AC)

  • Includes volt free changeover contacts that can be used to trigger rollershutter doors, gas shut-off valves, smoke vents, etc.

  • Mountable on a C-TEC NCP-26 surface box or a standard UK 25mm double gang back box (not supplied).

£38.90EX VAT
Add to Cart

CA Base sounder WHITE CA431A/W

SKU: CA431A/W
  • LPCB certified to EN54-3 & 17 and Kiwa Telefication certified to EN54-13.

  • Impressive 92dB(A) sound output @ 1m.

  • Onboard short-circuit loop isolator.

  • 5.5mA typical alarm current (460µA typical quiescent current) @ 24-40V DC.

  • Group addressing facility allows multiple devices to be operated simultaneously.

  • 4 selectable volume levels and 31 selectable tones.

  • Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use.

  • IP21C rated.

  • White ceiling fixing plate & detector spur wires included.

£18.90EX VAT
Add to Cart

C4 EN54-5 B HEAT DETECTOR

SKU: C4403B
  • A high-quality Type B high fixed temperature (75ºC) heat detector offering outstanding detection performance at a very competitive price.
  • Manufactured by C-TEC in the UK.
  • Third-party certified to EN54-5 by Intertek.
  • Wide 6-33V DC operating voltage.
  • Two 8mm x 2mm ultra-bright red LED indicating strips offering 360º visibility.
  • Compatible with our ActiV C4408D diode, C4408 non-diode and C4408R relay bases.
£10.90EX VAT
Add to Cart

CFP standard 8-zone panel CFP708-4

SKU: CFP708-4

CFP708-4

£174.90EX VAT
Add to Cart

BF456C/CC/W

SKU: BF456C/CC/W

BF456C/CC/W

£38.90EX VAT
Add to Cart

XFP 2 loop 32Z panel XP95/D

SKU: XFP502/X
  • Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
  • Compatibility with Apollo’s XP95/Discovery protocol.
  • Two independently programmable conventional sounder circuits.
  • Two programmable inputs.
  • A fault output relay and three programmable relay outputs with voltage free changeover contacts.
  • A selection of zone dependency/coincidence functions.
  • A day/night (building occupied/unoccupied) function.
  • An investigation delay period function.
  • Phased evacuation facility.
  • An alarm counter that records how many times the panel has been in alarm state.
  • Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
  • An integral EN54-4/A2 switch mode power supply.
  • Adjustable contamination levels.
  • Earth fault monitoring.
  • Combined keypad / keyswitch entry to Access Levels 2 and 3.
  • 999 event monitoring.
  • An intuitive Windows based upload-download PC program.
  • Optional flush-mounting bezel and glazed stainless steel enclosure also available.
  • Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
£717.90EX VAT
Add to Cart

XFP 2 loop 32Z panel Hochiki

SKU: XFP502/H
  • Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
  • Compatibility with Apollo’s XP95/Discovery protocol.
  • Two independently programmable conventional sounder circuits.
  • Two programmable inputs.
  • A fault output relay and three programmable relay outputs with voltage free changeover contacts.
  • A selection of zone dependency/coincidence functions.
  • A day/night (building occupied/unoccupied) function.
  • An investigation delay period function.
  • Phased evacuation facility.
  • An alarm counter that records how many times the panel has been in alarm state.
  • Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
  • An integral EN54-4/A2 switch mode power supply.
  • Adjustable contamination levels.
  • Earth fault monitoring.
  • Combined keypad / keyswitch entry to Access Levels 2 and 3.
  • 999 event monitoring.
  • An intuitive Windows based upload-download PC program.
  • Optional flush-mounting bezel and glazed stainless steel enclosure also available.
  • Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
£728.90EX VAT
Add to Cart

XFP 1 loop 32Z panel XP95/D

SKU: XFP501/X
  • Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
  • Compatibility with Apollo’s XP95/Discovery protocol.
  • Two independently programmable conventional sounder circuits.
  • Two programmable inputs.
  • A fault output relay and three programmable relay outputs with voltage free changeover contacts.
  • A selection of zone dependency/coincidence functions.
  • A day/night (building occupied/unoccupied) function.
  • An investigation delay period function.
  • Phased evacuation facility.
  • An alarm counter that records how many times the panel has been in alarm state.
  • Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
  • An integral EN54-4/A2 switch mode power supply.
  • Adjustable contamination levels.
  • Earth fault monitoring.
  • Combined keypad / keyswitch entry to Access Levels 2 and 3.
  • 999 event monitoring.
  • An intuitive Windows based upload-download PC program.
  • Optional flush-mounting bezel and glazed stainless steel enclosure also available.
  • Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
£520.90EX VAT
Add to Cart

XFP 1 loop 32Z panel Hochiki

SKU: XFP501/H
  • Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
  • Compatibility with Apollo’s XP95/Discovery protocol.
  • Two independently programmable conventional sounder circuits.
  • Two programmable inputs.
  • A fault output relay and three programmable relay outputs with voltage free changeover contacts.
  • A selection of zone dependency/coincidence functions.
  • A day/night (building occupied/unoccupied) function.
  • An investigation delay period function.
  • Phased evacuation facility.
  • An alarm counter that records how many times the panel has been in alarm state.
  • Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
  • An integral EN54-4/A2 switch mode power supply.
  • Adjustable contamination levels.
  • Earth fault monitoring.
  • Combined keypad / keyswitch entry to Access Levels 2 and 3.
  • 999 event monitoring.
  • An intuitive Windows based upload-download PC program.
  • Optional flush-mounting bezel and glazed stainless steel enclosure also available.
  • Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
£565.90EX VAT
Add to Cart

XFP 1 loop 16Z panel XP95/D

SKU: XFP501E/X
  • Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
  • Compatibility with Apollo’s XP95/Discovery protocol.
  • Two independently programmable conventional sounder circuits.
  • Two programmable inputs.
  • A fault output relay and three programmable relay outputs with voltage free changeover contacts.
  • A selection of zone dependency/coincidence functions.
  • A day/night (building occupied/unoccupied) function.
  • An investigation delay period function.
  • Phased evacuation facility.
  • An alarm counter that records how many times the panel has been in alarm state.
  • Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
  • An integral EN54-4/A2 switch mode power supply.
  • Adjustable contamination levels.
  • Earth fault monitoring.
  • Combined keypad / keyswitch entry to Access Levels 2 and 3.
  • 999 event monitoring.
  • An intuitive Windows based upload-download PC program.
  • Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
£446.90EX VAT
Add to Cart

XFP 1 loop 16Z panel Hochiki

SKU: XFP501E/H
  • Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
  • Compatibility with Apollo’s XP95/Discovery protocol.
  • Two independently programmable conventional sounder circuits.
  • Two programmable inputs.
  • A fault output relay and three programmable relay outputs with voltage free changeover contacts.
  • A selection of zone dependency/coincidence functions.
  • A day/night (building occupied/unoccupied) function.
  • An investigation delay period function.
  • Phased evacuation facility.
  • An alarm counter that records how many times the panel has been in alarm state.
  • Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
  • An integral EN54-4/A2 switch mode power supply.
  • Adjustable contamination levels.
  • Earth fault monitoring.
  • Combined keypad / keyswitch entry to Access Levels 2 and 3.
  • 999 event monitoring.
  • An intuitive Windows based upload-download PC program.
  • Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
£383.90EX VAT
Add to Cart

XFP 1 loop 16Z CAST

SKU: XFP501E/CA

C-TEC XFP501E/CA XFP 1 Loop 16 Zone Panel, C-TEC CAST. Max. 2 x 3.2Ah Batteries

C-TEC’s tried and trusted XFP one loop 16 zone addressable fire alarm panel – now available with C-TEC’s own digital fire alarm system protocol, CAST and fully certified to EN54 parts 2, 4 and 13.

With a powerful 40V 500mA loop driver allowing the connection of up to 255 CAST devices, the installation of a cost-effective, feature-packed addressable fire alarm system has never been easier.

Protocol Features

‘CAST’ is the world’s most-advanced ‘distributed intelligence’ fire alarm system protocol. Conceived, designed and realised by C-TEC as part of a five-year, multi-million pound project, it involved the creation of a powerful proprietary communication protocol (C-TEC Addressable System Technology, CAST) and multiple control panels & field devices. Now available to purchase.

Key Features

• 255 devices per loop.

• Autonomous decision-making for faster response times.

• Multiple type codes.

• 40V loop drive voltage.

• Two ‘soft’ addressing options – automatic via the panel or manual via a powerful handheld programmer.

• Powerful multi-level addressing facilitates easy device addition and swapped device identification.

• Multiple functionality at a single address (integrated devices) – due 2021.

• Volumes, tones & detector modes can be changed at compatible panels.

• High-speed data transmission and robust data transfer.

• Provides geographical location of short and open circuit faults (a short circuit isolator is included as standard in every CAST field device).

• Replace device function.

• Programmable multi-function status LED.

• Future seamless integration with other CAST life safety systems reducing energy, servicing, installation and repair costs.

• ENVISION Enabled – fully compliant with our new ENVISION Cloud-based Fire ‘IoT’ Remote Access, System Test and Site Management software package.

• Designed and manufactured in the UK.

Panel Features

• Certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB) and EN54-13 by Kiwa Telefication.

• Two independently programmable conventional sounder circuits.

• Two programmable inputs.

• A fault output relay and three programmable relay outputs with voltage free changeover contacts.

• A selection of zone dependency/coincidence functions.

• A day/night (building occupied/unoccupied) function.

• An investigation delay period function.

• Phased evacuation facility.

• An alarm counter that records how many times the panel has been in alarm state.

• Powerful short circuit protected loop drivers.

• An integral EN54-4/A2 switch mode.

• Adjustable contamination levels.

• Earth fault monitoring.

• Combined keypad / keyswitch entry to Access Levels 2 and 3.

• 500 event monitoring.

• An intuitive Windows based upload-download PC program.

• Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.

 

£313.90EX VAT