C-Tec
XFP 1 loop 32Z CAST
C-TEC XFP501/CA XFP 1 loop 32 Zone Panel, C-TEC CAST. Max. 2 x 7Ah Batteries
C-TEC’s tried and trusted XFP one loop 32 zone addressable fire alarm panel – now available with C-TEC’s own digital fire alarm system protocol, CAST and fully certified to EN54 parts 2, 4 and 13.
With a powerful 40V 450mA loop driver allowing the connection of up to 255 CAST devices, the installation of a robust, feature-packed addressable fire alarm system has never been easier.
Protocol Features
‘CAST’ is the world’s most-advanced ‘distributed intelligence’ fire alarm system protocol. Conceived, designed and realised by C-TEC as part of a five-year, multi-million pound project, it involved the creation of a powerful proprietary communication protocol (C-TEC Addressable System Technology, CAST) and multiple control panels & field devices.
Key Features
• 255 devices per loop.
• Autonomous decision-making for faster response times.
• Multiple type codes.
• 40V loop drive voltage.
• Two ‘soft’ addressing options – automatic via the panel or manual via a powerful handheld programmer.
• Powerful multi-level addressing facilitates easy device addition and swapped device identification.
• Multiple functionality at a single address (integrated devices) – due 2021.
• Volumes, tones & detector modes can be changed at compatible panels.
• High-speed data transmission and robust data transfer.
• Provides geographical location of short and open circuit faults (a short circuit isolator is included as standard in every CAST field device).
• Replace device function.
• Programmable multi-function status LED.
• Future seamless integration with other CAST life safety systems reducing energy, servicing, installation and repair costs.
• ENVISION Enabled – fully compliant with our new ENVISION Cloud-based Fire ‘IoT’ Remote Access, System Test and Site Management software package.
• Designed and manufactured in the UK.
Panel Features
• Certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB) and EN54-13 by Kiwa Telefication.
• Two independently programmable conventional sounder circuits.
• Two programmable inputs.
• A fault output relay and three programmable relay outputs with voltage free changeover contacts.
• A selection of zone dependency/coincidence functions.
• A day/night (building occupied/unoccupied) function.
• An investigation delay period function.
• Phased evacuation facility.
• An alarm counter that records how many times the panel has been in alarm state.
• Powerful short circuit protected loop drivers.
• An integral EN54-4/A2 switch mode.
• Adjustable contamination levels.
• Earth fault monitoring.
• Combined keypad / keyswitch entry to Access Levels 2 and 3.
• 500 event monitoring.
• An intuitive Windows based upload-download PC program.
• Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
Accessible Disabled Persons Toilet Alarm Kit NC951
- The UK’s market-leading Disabled Persons Toilet Alarm kit now with a combined ceiling and wall mountable pull cord unit.
- Includes everything required for a BS8300 compliant emergency assistance alarm.
- Easy to install & simple to use.
- Allows a distressed person to raise an alarm in an emergency. To operate, the user pulls the cord of the ceiling/wall pull to activate a light and sounder outside the WC and on the system’s Call Controller.
- The system’s ‘Call Accept’ function allows staff to send an intermittent call acknowledgment signal to the WC to confirm help is on the way.
- Includes an NC943B 12V 140mA Call Controller c/w standby battery & relay, NC807C Ceiling/Wall Pull, NC806CS Overdoor Light c/w Sounder, NC809DBBT Accessible Toilet Reset Point c/w Sounder & NC949 Accessible WC Sticker.
- Can be wired in 4 core stranded security cable.
- Can also be used as a single zone assistance alarm in changing rooms, solariums, interview rooms, reception areas & more.
HA BS5839-6 HAK/1 Domestic Fire Alarm Kit
- 1 x Hush-ActiV Controller c/w 72 hour standby battery
- 1 x 24V 250mA PSU
- 1 x ActiV multi sensor
- 1 x ActiV smoke detector
- 1 x ActiV heat detector
- 3 x ActiV detector bases
- 1 x ActiV base sounder c/w lid & adaptor plate
- Optional decor plates available for use with ceiling mounted ActiV devices to cover the larger hole left when used to retrofit older Grade D alarm devices.
Green handsfree EVC outstation surface EVC302GS
- Stylishly finished in tough, durable green steel.
- Offers true duplex speech.
- Features a ‘Push to Call or Answer’ button, a ‘Call in Progress’ LED, buzzer, microphone and loudspeaker.
- Includes connections for an optional induction loop system and a general-purpose open collector output that closes on activation of the unit.
- Meets and exceeds the requirements of BS 5839-9 when correctly installed.
8 Line SigTEL Master Controller c/w handset ECU-8
- Ideal for disabled refuge, fire telephone and stadium marshalling applications.
- Allows operators to communicate with up to eight disabled refuge or fire telephone outstations.
- Expandable to 16 lines using an ECU-8 expansion unit.
- Networking facility allows up to four controllers (plus any expansion units) to be interlinked allowing systems of up to 64 lines to be implemented.
- Supplied with a backlit LCD and handset.
- True duplex speech.
- Unique ‘auto-learn’ facility allows fast system set up.
- Can be semi-flush mounted using an AFP385 bezel.
- Operation can be maintained for 24 hours (standby) and 3 hours (in use) using 2 x 12V 7 Ahr batteries.
- Easily interfaced to NC951 accessible toilet alarms, PDA audio-frequency induction loop systems, strobes, CCTV activation relays, etc.
4 Line SigTEL Master Controller c/w handset ECU-4
- Ideal for disabled refuge, fire telephone and stadium marshalling applications.
- Allows operators to communicate with up to four disabled refuge or fire telephone outstations.
- Expandable to 12 lines using an ECU-8 expansion unit.
- Networking facility allows up to four controllers (plus any expansion units) to be interlinked allowing systems of up to 64 lines to be implemented.
- Supplied with a backlit LCD and handset.
- True duplex speech.
- Unique ‘auto-learn’ facility allows fast system set up.
- Can be semi-flush mounted using an AFP385 bezel.
- Operation can be maintained for 24 hours (standby) and 3 hours (in use) using 2 x 12V 7 Ahr batteries.
- Easily interfaced to NC951 accessible toilet alarms, PDA audio-frequency induction loop systems, strobes, CCTV activation relays, etc.
CFP Standard 4 zone panel CFP704-4
- Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
- Manufactured by C-TEC in the UK.
- Two detector zone circuits.
- Four conventional sounder circuits
- Integral 1.5A EN54-4/A2 compliant switch mode PSU.
- Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
- Two on-board relays (Fire and Fault).
- Two open-collector outputs (Remote and Reset).
- ‘Class change’ and alert inputs.
- Installer-friendly design.
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
- Low 25mA quiescent current.
- Multiple indicators.
- System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
- Space for two x 12V 3.3Ah VRLA batteries.
- Fully compatible with C-TEC’s ActiV range of conventional fire detectors.
CFP Standard 2 zone panel CFP702-4
- C-Tech CFP702-4
- LPCB Certified To The Latest Versions Of EN54 Parts 2 And 42
- 2 Zone Circuits
- 4 Conventional Sounder Circuits
- Two On-Board Relays (Fire And Fault)
- Integral 1.5A EN54-4/A2 Compliant Switch Mode PSU
- ‘Class Change’ And Alert Inputs
- Low Quiescent Current
- Multiple Indicators
- Space For 2 x 12V 3.2Ah SLA Batteries
CFP AlarmSense 8 zone two-wire panel CFP708-2
- LPCB certified to EN54 parts 2 and 4
- Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry to access level 2
- 2, 4 or 8 AlarmSense zone circuits (dependent on model purchased)
- Four conventional sounder circuits
- Integral 1.5A EN54-4/A2 compliant switch mode PSU
- Wide range of engineering functions including zone test, coincidence, zone delay and non- latching zones
- Two on-board relays (Fire and Fault)
- Two open-collector outputs (Remote and Reset)
- ‘Class change’ and alert inputs
- Installer-friendly design accommodates easy first fix and straightforward maintenance
- Attractive flush or surface mountable plastic lid and enclosure – no bezel required
- Low quiescent current
- Multiple indicators
- End of line units included (one per zone)
- Ancillary system expansion connections provided for up to eight two-wire repeaters (one CFP761 network driver card required per system) and optional CFP relay boards
- Space for two x 12V 3.3Ah VRLA batteries
C4 EN54-5 A1R heat detector C4403A1R
- LPCB certified to EN54-3 (Sounders) and EN54-23 (VADs)
- Provides ‘W-2.75-9’ rated light distribution when wall mounted (min. 0.4 lux over a 2.75 x 9m cuboid area). Also rated as a W-4-4 VAD
- Impressive 100dB(A) sound output @ 1m
- 31 selectable primary and secondary tone pairs and two volume levels (high and low)
- Three selectable VAD flash rates (0.5Hz, 1Hz, OFF)
- Alarm Current at 30Vdc = 12.2mA (0.5Hz) or 19.5mA (1Hz)
- Alarm Current at 18Vdc = 14.5mA (0.5Hz) or 25mA (1Hz)
- IP33C rated
- Manufactured in the UK by C-TEC
CA Mini input output module CA734
LPCB certified to EN54-17 & 18 and Kiwa Telefication certified to EN54-13.
Includes a switch monitor, signal relay and onboard loop isolator.
7mA typical alarm current (1mA typical quiescent current) @ 22-40V DC.
Four plastic tabs for surface or panel mounting.
Includes a 1A 30V DC volt-free changeover relay. Can also switch 0.3A @125V AC.
Offers Switch +Ve, –Ve, LED +V, –Ve and changeover relay connections
Future header pin offers expansion opportunities for peripheral I/O devices.
CA Compact ceiling VAD WHITE CA458A/SW
LPCB certified to EN54-17 & 23 and Kiwa Telefication certified to EN54-13.
Provides ‘C-3-8’ light distribution when ceiling mounted.
Can also provide ‘W-3-3.1’ light distribution when wall mounted.
Onboard short-circuit loop isolator.
460µA quiescent current.
7mA typical alarm current (460µA typical quiescent current) @ 27-40V DC (VAD lit).
Group addressing facility allows multiple devices to be operated simultaneously.
IP21C rated.
CA Compact ceiling sounder VAD WHITE CA451A/SW
LPCB certified to EN54-3, 17 & 23 and Kiwa Telefication certified to EN54-13.
Provides ‘C-3-8’ light distribution when ceiling mounted.
Can also provide ‘W-3-3.1’ light distribution when wall mounted.
Impressive 96dB(A) sound output @ 1m.
Onboard short-circuit loop isolator.
12.5mA typical alarm current (460µA typical quiescent current) @ 27-40V DC (VAD lit, sounder on max).
Group addressing facility allows multiple devices to be operated simultaneously.
4 selectable volume levels and 31 selectable tones.
IP21C rated.
CA Wall sounder VAD deep RED CA433A/DR
LPCB certified to EN54-3, 17 & 23 and Kiwa Telefication certified to EN54-13
Provides ‘W-2.75-9’ rated light distribution. Also rated as a W-4-4 VAD.
Impressive 100dB(A) sound output @ 1m.
Onboard short-circuit loop isolator.
13.5mA typical alarm current (550µA typical quiescent current) @ 27-40V DC (VAD lit, sounder on max).
Group addressing facility allows multiple devices to be operated simultaneously.
4 selectable volume levels and 32 selectable tones.
IP33C (Type B) rated.
CA Wall sounder deep IP55/65 RED CA430A/DR/65
LPCB certified to EN54-3 & 17 and Kiwa Telefication certified to EN54-13.
Impressive 100dB(A) sound output @ 1m.
Onboard short-circuit loop isolator.
6.5mA typical alarm current (460μA typical quiescent current) @24-40V DC (Sounder on max).
Group addressing facility allows multiple devices to be operated simultaneously.
4 selectable volume levels and 31 selectable tones.
IP55C rated.
CA Optical Smoke Detector CA430A/DR
C-TEC CA430A/DR HI-OUTPUT ADDRESSABLE WALL SOUNDER
The C-Tec CA430A/DR is a red wall mounted high output addressable wall sounder with IP33C deep base designed for use on C-Tec CAST protocol analogue addressable fire alarm systems.
Features
LPCB certified to EN54-3 & 17 and Kiwa Telefication certified to EN54-13.
Impressive 100dB(A) sound output @ 1m.
Onboard short-circuit loop isolator.
6.5mA typical alarm current (460µA typical quiescent current) @24-40V DC (Sounder on max).
Group addressing facility allows multiple devices to be operated simultaneously.
4 selectable volume levels and 31 selectable tones.
IP33C (Type B) rated.
C4 EN54-7 Optical detector C4416
- A high-quality optical smoke detector offering outstanding detection performance at a very competitive price
- Manufactured by C-TEC in the UK
- Third-party certified to EN54-7 by Intertek
- Carries the pan-European ‘CertAlarm’ mark
- Wide 6-33V DC operating voltage
- Two 8mm x 2mm ultra-bright red LED indicating strips offering 360º visibility
- Drift compensation functionality ensures detector sensitivity is automatically calibrated to suit prevailing conditions and/or increased contamination levels
- Compatible with our ActiV C4408D diode, C4408 non-diode and C4408R relay bases (all bases include an integrated detector/base locking mechanism and ID tag)
- Class A1 fixed heat, class B fixed heat, class A1R rate-of-rise and multi-sensor variants also available
- Excellent discounts for quantity orders
C4 EN54-29 Multi-sensor C4414
- A high-quality combined optical + heat multi-sensor offering outstanding detection performance at a very competitive price
- Manufactured by C-TEC in the UK
- Third-party certified to EN54-5 & 7 by Intertek
- Carries the pan-European ‘CertAlarm’ mark
- Wide 6-33V DC operating voltage
- Two 8mm x 2mm ultra-bright red LED indicating strips offering 360º visibility
- Drift compensation functionality ensures detector sensitivity is automatically calibrated to suit prevailing conditions and/or increased contamination levels
- Compatible with our ActiV C4408D diode, C4408 non-diode and C4408R relay bases (all bases include an integrated detector/base locking mechanism and ID tag)
- Class A1 fixed heat, class B fixed heat, class A1R rate-of-rise and optical variants also available
- Excellent discounts for quantity orders
C4 diode base C4408D
- Third-party certified to the relevant parts of EN54 in conjunction with our ActiV detectors
- Easy to fit with lots of working space
- Can be ceiling mounted in any orientation due to the true 360° degree viewing angle of the LED indicator strips on all ActiV detectors
- Integrated detector/base locking mechanism, head removal tool and ID tag
- Simple ‘click and twist’ design
- Remote LED terminals for the optional connection to a BF318 Remote indicator
- Bright tin plated steel terminals can accept fire rated cable of up to 2.5mm in diameter
- C4408D diode and C4408 non-diode bases available*
- Compatible with C-TEC’s entire range of ActiV conventional smoke and heat detectors
CX C Class Base sounder VAD WHITE BF456A/CX/W
- Third-party certified to EN54-3 (Sounders), EN54-23 (VADs) and 17 (Isolators) by the LPCB
- Provides ‘C-3-8’ light distribution (min 0.4 lux over a 3 x 8m cylindrical area)
- Supplied with a BF431QCP quick connect plate and detector spur wires
- Impressive 96dB(A) sound output @ 1m
- Onboard short-circuit loop isolator
- 550µA quiescent current
- 14mA alarm current @24V DC (VAD lit, sounder on max)
- Group addressing facility allows multiple devices to be operated simultaneously
- 7 selectable volume levels and up to 15 selectable tone pairs
- Optional BF330CTLIDW white or BF330CTLIDR red cap available for stand-alone use
- IP21C rated