Panels
XFP 1 loop 16Z panel XP95/D
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
XFP 1 loop 16Z panel Hochiki
- Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
- Compatibility with Apollo’s XP95/Discovery protocol.
- Two independently programmable conventional sounder circuits.
- Two programmable inputs.
- A fault output relay and three programmable relay outputs with voltage free changeover contacts.
- A selection of zone dependency/coincidence functions.
- A day/night (building occupied/unoccupied) function.
- An investigation delay period function.
- Phased evacuation facility.
- An alarm counter that records how many times the panel has been in alarm state.
- Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
- An integral EN54-4/A2 switch mode power supply.
- Adjustable contamination levels.
- Earth fault monitoring.
- Combined keypad / keyswitch entry to Access Levels 2 and 3.
- 999 event monitoring.
- An intuitive Windows based upload-download PC program.
- Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
XFP 1 loop 16Z CAST
C-TEC XFP501E/CA XFP 1 Loop 16 Zone Panel, C-TEC CAST. Max. 2 x 3.2Ah Batteries
C-TEC’s tried and trusted XFP one loop 16 zone addressable fire alarm panel – now available with C-TEC’s own digital fire alarm system protocol, CAST and fully certified to EN54 parts 2, 4 and 13.
With a powerful 40V 500mA loop driver allowing the connection of up to 255 CAST devices, the installation of a cost-effective, feature-packed addressable fire alarm system has never been easier.
Protocol Features
‘CAST’ is the world’s most-advanced ‘distributed intelligence’ fire alarm system protocol. Conceived, designed and realised by C-TEC as part of a five-year, multi-million pound project, it involved the creation of a powerful proprietary communication protocol (C-TEC Addressable System Technology, CAST) and multiple control panels & field devices. Now available to purchase.
Key Features
• 255 devices per loop.
• Autonomous decision-making for faster response times.
• Multiple type codes.
• 40V loop drive voltage.
• Two ‘soft’ addressing options – automatic via the panel or manual via a powerful handheld programmer.
• Powerful multi-level addressing facilitates easy device addition and swapped device identification.
• Multiple functionality at a single address (integrated devices) – due 2021.
• Volumes, tones & detector modes can be changed at compatible panels.
• High-speed data transmission and robust data transfer.
• Provides geographical location of short and open circuit faults (a short circuit isolator is included as standard in every CAST field device).
• Replace device function.
• Programmable multi-function status LED.
• Future seamless integration with other CAST life safety systems reducing energy, servicing, installation and repair costs.
• ENVISION Enabled – fully compliant with our new ENVISION Cloud-based Fire ‘IoT’ Remote Access, System Test and Site Management software package.
• Designed and manufactured in the UK.
Panel Features
• Certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB) and EN54-13 by Kiwa Telefication.
• Two independently programmable conventional sounder circuits.
• Two programmable inputs.
• A fault output relay and three programmable relay outputs with voltage free changeover contacts.
• A selection of zone dependency/coincidence functions.
• A day/night (building occupied/unoccupied) function.
• An investigation delay period function.
• Phased evacuation facility.
• An alarm counter that records how many times the panel has been in alarm state.
• Powerful short circuit protected loop drivers.
• An integral EN54-4/A2 switch mode.
• Adjustable contamination levels.
• Earth fault monitoring.
• Combined keypad / keyswitch entry to Access Levels 2 and 3.
• 500 event monitoring.
• An intuitive Windows based upload-download PC program.
• Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
XFP 1 loop 32Z CAST
C-TEC XFP501/CA XFP 1 loop 32 Zone Panel, C-TEC CAST. Max. 2 x 7Ah Batteries
C-TEC’s tried and trusted XFP one loop 32 zone addressable fire alarm panel – now available with C-TEC’s own digital fire alarm system protocol, CAST and fully certified to EN54 parts 2, 4 and 13.
With a powerful 40V 450mA loop driver allowing the connection of up to 255 CAST devices, the installation of a robust, feature-packed addressable fire alarm system has never been easier.
Protocol Features
‘CAST’ is the world’s most-advanced ‘distributed intelligence’ fire alarm system protocol. Conceived, designed and realised by C-TEC as part of a five-year, multi-million pound project, it involved the creation of a powerful proprietary communication protocol (C-TEC Addressable System Technology, CAST) and multiple control panels & field devices.
Key Features
• 255 devices per loop.
• Autonomous decision-making for faster response times.
• Multiple type codes.
• 40V loop drive voltage.
• Two ‘soft’ addressing options – automatic via the panel or manual via a powerful handheld programmer.
• Powerful multi-level addressing facilitates easy device addition and swapped device identification.
• Multiple functionality at a single address (integrated devices) – due 2021.
• Volumes, tones & detector modes can be changed at compatible panels.
• High-speed data transmission and robust data transfer.
• Provides geographical location of short and open circuit faults (a short circuit isolator is included as standard in every CAST field device).
• Replace device function.
• Programmable multi-function status LED.
• Future seamless integration with other CAST life safety systems reducing energy, servicing, installation and repair costs.
• ENVISION Enabled – fully compliant with our new ENVISION Cloud-based Fire ‘IoT’ Remote Access, System Test and Site Management software package.
• Designed and manufactured in the UK.
Panel Features
• Certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB) and EN54-13 by Kiwa Telefication.
• Two independently programmable conventional sounder circuits.
• Two programmable inputs.
• A fault output relay and three programmable relay outputs with voltage free changeover contacts.
• A selection of zone dependency/coincidence functions.
• A day/night (building occupied/unoccupied) function.
• An investigation delay period function.
• Phased evacuation facility.
• An alarm counter that records how many times the panel has been in alarm state.
• Powerful short circuit protected loop drivers.
• An integral EN54-4/A2 switch mode.
• Adjustable contamination levels.
• Earth fault monitoring.
• Combined keypad / keyswitch entry to Access Levels 2 and 3.
• 500 event monitoring.
• An intuitive Windows based upload-download PC program.
• Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
Full colour screen IP paging console PPM-IT5
- Voltage:18 – 26 VDC
- Power consumption:250 mA
- Frequency response:-3 dB @ 200 Hz to 8 kHz
- THD:< 1% @ 1 kHz
- Output impedance:100 Ω
24 Port Cat 5e Patch Panel PNL24AB
24 Port Cat 5e Patch Panel
The Allrack 24 port Cat 5e patch panel offers Category 5e performance when installed using uTP Cat 5e cable. This 1u high patch panel fits all 19″ cabinets and racks. IDC rear termination, RJ45 socket presention on front of panel.
Security system control panel with support for photo verification & LTE cellular module HUB2-WHITE-4G
Security system control panel with support for photo verification & LTE cellular module
Spare accessories available (likely on a special order basis), if required please speak to Sales or your BDM.
In control of security, not your private life
Alarm photo verification in 9 seconds
Always connected — via cable and cellular networks
Communication with the outside world is critical for the security system control panel. Its reliability and stability guarantee timely alarm transmission to the security company and users.
Hub 2 can be simultaneously connected to three Internet service providers — via Ethernet cable and 2G, 3G, and LTE 2 cellular networks. The automatic switching between channels takes seconds.
Guaranteed delivery of alarms and visual alarm verifications
Flexibility at the core
Controlled with apps
We refrained from control buttons on the control panel body and archaic interfaces — apps are more convenient and reliable. They connect to a hub via a secure channel through the Ajax Cloud server located in several AWS data centres. Server availability in 2021 was 99.995%.
Apps allow system users with administrator rights to manage the security of the facility, change settings of the hub and the devices connected to it, create scenarios, and monitor events. From a smartphone or a PC. On the site and remotely.
Automates security
Resistant to sabotage
Future-proof
Hub 2 runs OS Malevich — a real-time operating system developed by Ajax Systems. OS Malevich is extremely stable, immune to viruses, and protected from cyberattacks. Modular architecture simplifies the constant upgrading of OS Malevich.
Hub receives new features several times a year with over-the-air updates. The update process is automatic and takes minutes when the security system is disarmed. The hardware configuration will allow Hub 2 to evolve and remain relevant for years to come.
Hassle-free installation
Hub 2 is ready to operate out of the box. All communication modules, power supply, and backup battery are already installed. To start setting up the system, you need to connect the device to the power supply and the Internet, insert the SIM cards, and scan the QR code through the app. With the SmartBracket mounting panel, there is no need to disassemble the device body during installation.
Connecting security devices, video cameras, users, testing the radio signal, creating groups and scenarios, even sending a request for connection to the CMS — all system settings are always available in the Ajax apps. Whether you are at the site or not.
Easy security system upgrade
Intelligent control panel with visual alarm verification HUB2-WHITE
- Device polling period from 12 seconds
- Detection connection loss with a hub in 60 seconds
- Operation on backup battery up to 15 hours