Fike
Fike 402-0006 Twinflex Callpoint with cover Fike-402-0006-Twinflex-Callpoint-with-cover
The Twinflex Manual Call Point (MCP) allows for user activation of the fire alarm system. Once operated the device latches into the alarm position and requires manually resetting via a special key.
This device is compatible with the range of Twinflex Fire Alarm Control Panels and comprises a 2-wire zone-powered Manual Call Point (MCP). This device may be installed on the same zone as the Twinflex Multipoint detector/sounder and other associated Twinflex devices.
Re-settable element
LED indication for end of line
Includes reset key and protective cover
Can be surface/flush mounted
Fike 302-0012 Twinflex Flashpoint low profile Fike-302-0012-Twinflex-Flashpoint-low-profile
Ideal as a visual indicator directly from the 2-wire zone
Complies with European Standard EN54 part 4
During the alarm, the flashpoint synchronisation is uniquely reset every 10 seconds.
For simple installation, first fix the base then simply plug in the unit
Anti-tamper mechanism – will only be released with the head removal tool
Fike 302-0001 Twinflex Hatari Sounder Red Fike-302-0001-Twinflex-Hatari-Sounder-Red
The twinflex Hatari is designed to comply with the European standard EN54 part 3. The stand alone Hatari sounder can be utilised where extra sound output on the zone is a requirement, or for areas that do not require automatic detection technology. The field wiring is terminated to fixed connectors in the base, and a deep base is available as a separate item if required.
A bayonet locking mechanism means the sounder is easy to install and the anti-tamper feature ensures that the Hatari is only released with the use of the head removal tool
Fully Selectable Sounder Output Level
100 dB Output
Upto 6 Per Zone
Anti-tamper Bayonet Locking Mechanism
Fike TwinflexPro2 2 Zone Boxed Kit (Approved) – 604-0002 Fike-Twinflex-2-Zone-Kit
The Fike 604-0002 is a 2 Zone Contractor Kit ideal for use in buildings in the UK.
This kit is based upon the popular Fike Twinflex Pro range of two wire fire alarm system equipment. This means that the detectors, call points and sounders can all be installed on the same zone circuit. This reduces installation costs, time and disruption compared to traditional conventional fire alarm systems, where the sounders would need to be installed separately to the detectors and call points. This kit includes the Twinflex Multipoint detectors which can be used as either a smoke or heat detector. This is selectable by simply adjusting the switches on the reverse of the detector. This means that separate smoke and heat detectors don’t need to be ordered.
The Fike 604 0002 2 Zone Contractor Kit includes the following equipment:
- 1 x Fike 505 0002 Twinflex Pro 2 Zone Fire Alarm Control Panel
- 7 x Fike 204 0001 Twinflex Multipoint Detector with Sounder
- 2 x Fike 402 0006 Manual Call Point
- 1 x Fike 25 0046 201 Detector Head Removal Tool
Fike TwinflexPro2 2 Wire 8 Zone Control Panel (CPR Compliant) – 505-0008 FIKE-Twinflex-8-Zone-Panel
- 4 line x 20 character LCD display
- Ability to differentiate between smoke detector, heat detector or a manual call point alarms
- Alarm confirmation feature
- Available in 2, 4, and 8 zone panel versions
- RS485 Connection to up to 8 Repeater panels
- Highlighted selection menu
- Event log storing up to 500 events
- 3 enhanced test modes
- Allows detectors and sounders to be installed on the same pair of wires
- Up to 32 devices per zone
- Built-in EOL capability in all devices
- 7 modes of detection
- Zone can be configured to day/night detection mode
- Delay programming options
Fike TwinflexPro2 2 Wire 4 Zone Control Panel (CPR Compliant) – 505-0004 FIKE-Twinflex-4-Zone-Panel
- 4 line x 20 character LCD display
- Ability to differentiate between smoke detector, heat detector or a manual call point alarms
- Alarm confirmation feature
- Available in 2, 4, and 8 zone panel versions
- RS485 Connection to up to 8 Repeater panels
- Highlighted selection menu
- Event log storing up to 500 events
- 3 enhanced test modes
- Allows detectors and sounders to be installed on the same pair of wires
- Up to 32 devices per zone
- Built-in EOL capability in all devices
- 7 modes of detection
- Zone can be configured to day/night detection mode
- Delay programming options
Fike 802-0006 Twinflex I/O Unit Fike-802-0006-Twinflex-I/O-Unit
The Twinflex I/O module is a Relay interfacing module with monitored input to provide shutdown and monitoring facilities from the Twinflex zone. Mounted in a standard double gang box, including two sets of 2A rated SPCO relay contacts, one monitored input and inbuilt ‘End of Line’.
Input/Output module
Mounted on a double gang back-box
Twinflex compatible
Fike 604-0008 Twinflex 8 Zone Kit Fike-604-0008-Twinflex-8-Zone-Kit
Based upon the popular Fike Twinflex Pro range of two wire fire alarm system equipment. As a result the detectors, call points and sounders can all be installed on the same zone circuit. This helps to reduce installation costs, time and disruption compared to traditional conventional fire alarm systems
Included in the kit are Twinflex Multipoint detectors which can be used as either a smoke or heat detector. This mode is changed by adjusting the switches on the reverse of the detector. As a result separate smoke and heat detectors don’t need to be ordered.
Included in the kit
1 x Fike Twinflex 8 Zone Panel
7 x Twinflex Multipoint Detector with Sounder
2 x Twinflex Manual Call Point
1 x Head Removal Tool
Fike 604-0004 Twinflex 4 Zone Kit Fike-604-0004-Twinflex-4-Zone-Kit
Based upon the popular Fike Twinflex Pro range of two wire fire alarm system equipment. As a result the detectors, call points and sounders can all be installed on the same zone circuit. This helps to reduce installation costs, time and disruption compared to traditional conventional fire alarm systems
Included in the kit are Twinflex Multipoint detectors which can be used as either a smoke or heat detector. This mode is changed by adjusting the switches on the reverse of the detector. As a result separate smoke and heat detectors don’t need to be ordered.
Included in the kit
1 x Fike Twinflex 4 Zone Panel
7 x Twinflex Multipoint detectors with sounder
2 x Twinflex manual call points
1 x Head removal tool
Fike 505-0002 TwinflexPro2 2 Wire 2 Zone Control Panel (CPR Compliant) Fike-Twinflex-2-Zone-Panel
- 4 line x 20 character LCD display
- Ability to differentiate between smoke detector, heat detector or a manual call point alarms
- Alarm confirmation feature
- Available in 2, 4, and 8 zone panel versions
- RS485 Connection to up to 8 Repeater panels
- Highlighted selection menu
- Event log storing up to 500 events
- 3 enhanced test modes
- Allows detectors and sounders to be installed on the same pair of wires
- Up to 32 devices per zone
- Built-in EOL capability in all devices
- 7 modes of detection
- Zone can be configured to day/night detection mode
- Delay programming options
Fike 204-0012 Twinflex ASD Detector with sounder & strobe Fike-204-0012-Twinflex-ASD-Detector-with-sounder-and-strobe
2 Wire Multipoint ASD detector with Sounder / Strobe can be set to any one of 3 Smoke modes, 3 Heat modes as well as a Combined Mode (Smoke 2 and Heat 2) where a smoke or heat source can trigger a fire decision.
Twinflex Multipoint ASD Detector with Sounder and StrobeÂ
Smoke, Heat Alarm, Sounder or Combined Mode
Self-calibrates every 6 hours
Continuously monitors for dust contamination
Easily removable for maintenance at height
Multipoint Detectors for use with Twinflex Pro2 Alarm Panel
Fike 204-0003 Twinflex ASD Detector no sounder Fike-204-0003-Twinflex-ASD-Detector-no-sounder
2 Wire Multipoint ASD detector with Sounder can be set to any one of 3 Smoke modes, 3 Heat modes as well as a Combined Mode (Smoke 2 and Heat 2) where a smoke or heat source can trigger a fire decision
Twinflex Multipoint ASD Detector without Sounder
Smoke, Heat Alarm or Combined Mode
Self-calibrates every 6 hours
Continuously monitors for dust contamination
Easily removable for maintenance at height
Multipoint Detectors for use with Twinflex Pro2 Alarm PanelÂ
Fike 204-0001 Twinflex ASD Detector with sounder Fike-204-0001-Twinflex-ASD-Detector-with-sounder
Twinflex Multipoint ASD Detector with Sounder
Smoke, Heat Alarm, Sounder or Combined Mode
Self-calibrates every 6 hours
Continuously monitors for dust contamination
Easily removable for maintenance at height
Multipoint Detectors for use with Twinflex Pro2 Alarm PanelÂ