ESP Two Wire Fire Panel Spare Key MAGDUOPK
- Spare Key for MAGDUO Panels (Pack of 2)
- Suitable for MAGDUO2, MAGDUO4 & MAGDUO8
Morley MAx 4 Loop Exp. 6/8 loop SSE,Apollo Morley-MAx-4-Loop-Exp.-6/8-loop-SSE-Apollo
- 4 access levels in accordance with EN 54 standards.
- Programmable text (32 characters) for points and zones.
- Up to 2000 soft zones, 400 logical groups in stand-alone systems and 1600 groups in network configuration with 64 panels or 128 total loops.
- Control-by-event (CBE) equations for activations with logical operators (AND, OR, DEL, etc).
- Historical log stores 10,000 events, plus 4,000 active events in non-volatile memory (standalone or network configuration).
- Clock in real time.
- Auto-programming lines with automatic recognition of the model of the devices.
- Decision algorithms for the alarm, prealarm and faults.
- Automatic day / night sensitivity change.
- Indication of the need to clean the smoke sensors.
Morley MAx 2 Loop Panel SSE, Apollo Protocols Morley-MAx-2-Loop-Panel-SSE-Apollo-Protocols
Morley MAx panels are multiprocessor fire detection systems that are suitable for configuration of a wide range of installations.
The system offers fire detection solutions integrated for many applications, like hotels, offices, hospitals, industrial environments and production facilities.
MAx panels are not a simple FACP but an advanced very powerful fire detection system that uses the CAN bus technology. This protocol, originally designed for operation in industrial environments, makes the system highly resistant to external factors as electrical disturbances and other sources of false alarms.
The system is certified in compliance with the standards EN 54-2, EN 54-4.
Morley MAx 2 loop card MA-8000, MIAS,SSE,Apollo Morley-MAx-2-loop-card-MA-8000-MIAS-SSE-Apollo
Morley-IAS MA-LIB2-01 MAX Series, Expansion Card for MA-8000, 2-Loop
Fike TwinflexPro2 2 Wire 8 Zone Control Panel (CPR Compliant) – 505-0008 FIKE-Twinflex-8-Zone-Panel
- 4 line x 20 character LCD display
- Ability to differentiate between smoke detector, heat detector or a manual call point alarms
- Alarm confirmation feature
- Available in 2, 4, and 8 zone panel versions
- RS485 Connection to up to 8 Repeater panels
- Highlighted selection menu
- Event log storing up to 500 events
- 3 enhanced test modes
- Allows detectors and sounders to be installed on the same pair of wires
- Up to 32 devices per zone
- Built-in EOL capability in all devices
- 7 modes of detection
- Zone can be configured to day/night detection mode
- Delay programming options
Fike TwinflexPro2 2 Wire 4 Zone Control Panel (CPR Compliant) – 505-0004 FIKE-Twinflex-4-Zone-Panel
- 4 line x 20 character LCD display
- Ability to differentiate between smoke detector, heat detector or a manual call point alarms
- Alarm confirmation feature
- Available in 2, 4, and 8 zone panel versions
- RS485 Connection to up to 8 Repeater panels
- Highlighted selection menu
- Event log storing up to 500 events
- 3 enhanced test modes
- Allows detectors and sounders to be installed on the same pair of wires
- Up to 32 devices per zone
- Built-in EOL capability in all devices
- 7 modes of detection
- Zone can be configured to day/night detection mode
- Delay programming options
Fike 505-0002 TwinflexPro2 2 Wire 2 Zone Control Panel (CPR Compliant) Fike-Twinflex-2-Zone-Panel
- 4 line x 20 character LCD display
- Ability to differentiate between smoke detector, heat detector or a manual call point alarms
- Alarm confirmation feature
- Available in 2, 4, and 8 zone panel versions
- RS485 Connection to up to 8 Repeater panels
- Highlighted selection menu
- Event log storing up to 500 events
- 3 enhanced test modes
- Allows detectors and sounders to be installed on the same pair of wires
- Up to 32 devices per zone
- Built-in EOL capability in all devices
- 7 modes of detection
- Zone can be configured to day/night detection mode
- Delay programming options
Advanced MX-5401N Advanced-MX-5401N
Nittan Evolution Protocol
1-4 loop addressable fire control panel c/w 1 loop card in large enclosure
Up to 254 devices per loop (protocol dependent)
Up to 200,000 devices per network
Networkable up to 200 nodes
Built in voltage and current meters
On board or optional remote battery temperature sensor
Advanced’s simple select and click programming and configuration
Quick start and protect – A working system after an Auto learn is performed
20 built-in, fully programmable LEDs
5000 event log entries
201 programmable false alarm management areas per panel
Timed enablement of isolated zones, input and output devices
Backward compatible with MxPro 4 network
Approved to EN54 Parts 2, 4 and 13
Certified by FM Approvals to EN54 Parts 2 and 4
Autolearn and Loop detection
Up to 2000 fire detection zones
True peer-to-peer networking
Supports intelligent/programmable remote terminals, BMS interface, IP Gateway and I/O Drivers
Circuit monitoring from any panel or repeater
Direct USB and RS232 PC connections
Peripheral expansion built in
4 programmable push buttons
Complete device history from each panel
Programmable screen logo
Advanced logic delivering huge configuration opportunities
Advanced MX-5401 Advanced-MX-5401
Apollo/Hochiki Protocol
1-4 loop addressable fire control panel c/w 1 loop card in large enclosure
Up to 254 devices per loop (protocol dependent)
Up to 200,000 devices per network
Networkable up to 200 nodes
Built in voltage and current meters
On board or optional remote battery temperature sensor
Advanced’s simple select and click programming and configuration
Quick start and protect – A working system after an Auto learn is performed
20 built-in, fully programmable LEDs
5000 event log entries
201 programmable false alarm management areas per panel
Timed enablement of isolated zones, input and output devices
Backward compatible with MxPro 4 network
Approved to EN54 Parts 2, 4 and 13
Certified by FM Approvals to EN54 Parts 2 and 4
Autolearn and Loop detection
Up to 2000 fire detection zones
True peer-to-peer networking
Supports intelligent/programmable remote terminals, BMS interface, IP Gateway and I/O Drivers
Circuit monitoring from any panel or repeater
Direct USB and RS232 PC connections
Peripheral expansion built in
4 programmable push buttons
Complete device history from each panel
Programmable screen logo
Advanced logic delivering huge configuration opportunities
Advanced MX-5201N Advanced-MX-5201N
Nittan Evolution Protocol
1-2 loop addressable fire control panel c/w 1 loop card in medium enclosure
Up to 254 devices per loop (protocol dependent)
Up to 200,000 devices per network
Networkable up to 200 nodes
Built in voltage and current meters
On board or optional remote battery temperature sensor
Advanced’s simple select and click programming and configuration
Quick start and protect – A working system after an Auto learn is performed
20 built-in, fully programmable LEDs
5000 event log entries
201 programmable false alarm management areas per panel
Timed enablement of isolated zones, input and output devices
Backward compatible with MxPro 4 network
Approved to EN54 Parts 2, 4 and 13
Certified by FM Approvals to EN54 Parts 2 and 4
Autolearn and Loop detection
Up to 2000 fire detection zones
True peer-to-peer networking
Supports intelligent/programmable remote terminals, BMS interface, IP Gateway and I/O Drivers
Circuit monitoring from any panel or repeater
Direct USB and RS232 PC connections
Peripheral expansion built in
4 programmable push buttons
Complete device history from each panel
Programmable screen logo
Advanced logic delivering huge configuration opportunities
Advanced MX-5201 Advanced-MX-5201
Apollo/Hochiki Protocol
1-2 loop addressable fire control panel c/w 1 loop card in medium enclosure
Up to 254 devices per loop (protocol dependent)
Up to 200,000 devices per network
Networkable up to 200 nodes
Built in voltage and current meters
On board or optional remote battery temperature sensor
Advanced’s simple select and click programming and configuration
Quick start and protect – A working system after an Auto learn is performed
20 built-in, fully programmable LEDs
5000 event log entries
201 programmable false alarm management areas per panel
Timed enablement of isolated zones, input and output devices
Backward compatible with MxPro 4 network
Approved to EN54 Parts 2, 4 and 13
Certified by FM Approvals to EN54 Parts 2 and 4
Autolearn and Loop detection
Up to 2000 fire detection zones
True peer-to-peer networking
Supports intelligent/programmable remote terminals, BMS interface, IP Gateway and I/O Drivers
Circuit monitoring from any panel or repeater
Direct USB and RS232 PC connections
Peripheral expansion built in
4 programmable push buttons
Complete device history from each panel
Programmable screen logo
Advanced logic delivering huge configuration opportunities
Advanced MX-5101N Advanced-MX-5101N
Nittan Evolution Protocol
1 loop addressable fire control panel in small enclosure
Up to 254 devices per loop (protocol dependent)
Up to 200,000 devices per network
Networkable up to 200 nodes
Built in voltage and current meters
On board or optional remote battery temperature sensor
Advanced’s simple select and click programming and configuration
Quick start and protect – A working system after an Auto learn is performed
20 built-in, fully programmable LEDs
5000 event log entries
201 programmable false alarm management areas per panel
Timed enablement of isolated zones, input and output devices
Backward compatible with MxPro 4 network
Approved to EN54 Parts 2, 4 and 13
Certified by FM Approvals to EN54 Parts 2 and 4
Autolearn and Loop detection
Up to 2000 fire detection zones
True peer-to-peer networking
Supports intelligent/programmable remote terminals, BMS interface, IP Gateway and I/O Drivers
Circuit monitoring from any panel or repeater
Direct USB and RS232 PC connections
Peripheral expansion built in
4 programmable push buttons
Complete device history from each panel
Programmable screen logo
Advanced logic delivering huge configuration opportunities
Advanced MX-5101 Advanced-MX-5101
- 20 programmable Zonal / 25 System LEDs.
- Apollo, Argus Vega, Hochiki & Nittan Evolution protocol support.
- Advanced graphical LCD user interface and support for up to 200 fire zones by default allowing full
- EN54 compliance without additional hardware.
- Dedicated USB & RS232 Serial Port for direct PC or modem connection.
- Installer friendly Auto-learn, Loop Detection and On-board Scope facility.
- Graphical display configurable for virtually any language.
- Robust removable equipment chassis with plug-in connectors for simple fixing and cable termination.
- Integral P-Bus for system expansion via available option cards.
- Ad-NeT peer-to-peer network with up to 2000 zones
- Approved to BS EN54 part 2, 4 and 13
Advanced MX-5020 Advanced-MX-5020
MxPro 5 Remote Control Terminal – Standard Network
Includes built-in standard network card
The RCT has additional sector based control keys for Silence, Mute, Resound and Reset, which allows other networked panels to selectively respond to controls as programmed. E.g. on a site with multiple buildings, a user may be allowed to silence and reset fires originating in their own building. Fires originating from other buildings are displayed but cannot be reset.
Fully on-site programmable via onboard alphanumeric keypad or PC configuration tools
View all information from across the network
By using flash memory and an advanced graphical display, the remote terminals can be easily configured to operate in virtually any language, with any character set and allows for the installer’s logo and company details to be displayed on the LCD during normal operation
Networked for system display or control
Programmable switch input
> Graphical LCD display
> Ad-NeT/Ad-Net+ compatible
> Slide-in labels
> Small, robust and compact
> 24V DC operating voltage
> 3-year warranty
> Disable/enable options
Advanced MX-5010 Advanced-MX-5010
MxPro 5 Remote Display Terminal – Standard Network
Includes built-in standard network card
The RDT has additional control keys for Mute which allows other network panels’ warning buzzer to be muted
Fully on-site programmable via onboard alphanumeric keypad or PC configuration tools
View all information from across the network
By using flash memory and an advanced graphical display, the remote terminals can be easily configured to operate in virtually any language, with any character set and allows for the installer’s logo and company details to be displayed on the LCD during normal operation
Networked for system display or control
Programmable switch input
Graphical LCD display
Ad-NeT/Ad-Net+ compatible
Slide-in labels
Small, robust and compact
24V DC operating voltage
3-year warranty
Disable/enable options
Single Loop Touch Screen Fire Alarm Panel Evolution1
- 4.3 inch touch screen
- Easy to use configuration software
- Full cause and effect programming at Panel or PC Configuration tool
- Up to 254 devices on the loop
- 254 zones available
- Network Card built in for networking up to 16 panels
- Remote Access via the “Nittan Portal” (Future Development)
- 2 x configurable RS485 ports
- Up to 8 password protected users
- Switch mode power supply
- EN 54 part 2 and part 4
ESP 2 Wire Repeater Panel MAGDUOREP
- Compatible with MAGDUO 4 or 8 zones control panels only
- Reports MAGDUO panel events to a remote location
- Capable of performing system controls (i.e. Silence Alarms, Reset, Sound Alarms & Silence Buzzer)
- Maximum of 8 repeater panels can be connected to a single control panel
ESP 2 Wire Control Panel 2 Zones MAGDUO2B
- Two Wire fire alarm system
- Active end of line monitoring and head removal
- Up to 32 devices per zone (Dependent on Device Loading Unit: DLU)
- 4 line x 20 character LCD display
- Ability to differentiate between smoke detector, heat detector or a manual call point alarms
- Alarm confirmation feature
- Event log storing up to 500 events
- 3 enhanced test modes
- Zone can be configured to day/night detection mode
- Delay programming options
- Certified to EN54 2/4 Standards
- Requires 2 x 12V 2.3Ah batteries (BAT32)
- Optional extended battery box with capacity for 2 x 12V 7.0Ah batteries
ESP 2 Zone Fire Panel MAG2P
- 2 programmable zones
- Active end of line monitoring and head removal
- 30 fire detectors per zone
- Unlimited number of call points per zone
- Integral sound alarm button
- 'Class change' facility
- Enable/disable security key
- One man walk test facility
- Volt free fire change over relay
- Volt free fault change over relay
- Individual sounder circuit fault ID
- Individual zone/sounder isolate
- CE certified to EN54 P2/4
- Requires only 1x12v battery
- MAG2P – ABS casing
ESP Repeater Panel MAGPRO-REP
- Wall-mount design
- Only compatible with MAGPRO16 Ver2.8 and higher
- Compatible with MAGPRO96
- Requires 24VDC External Power Supply
- Max consumption of 0.11A (110mA)
- Each panel in network will require a MAGPRO-NIC
- Maximum of 32 panels in the network
- 1000m distance from MAGPRO-REP to MAGPRO Panel
- Dimensions 200 x 330 x 48mm
- Ring type network
- 10,000 event log within the repeater