Results per page 20 All

DBD-0002

SKU: DBD-0002

DBD-0002

£91.90EX VAT
Add to Cart

CFP708-4

SKU: CFP708-4

CFP708-4

£152.90EX VAT
Add to Cart

Hikvision DS-PWA64-L-WE

SKU: DS-PWA64-L-WE

Hikvision DS-PWA64-L-WE

XFP 2 loop 32Z panel XP95/D

SKU: XFP502/X
  • Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
  • Compatibility with Apollo’s XP95/Discovery protocol.
  • Two independently programmable conventional sounder circuits.
  • Two programmable inputs.
  • A fault output relay and three programmable relay outputs with voltage free changeover contacts.
  • A selection of zone dependency/coincidence functions.
  • A day/night (building occupied/unoccupied) function.
  • An investigation delay period function.
  • Phased evacuation facility.
  • An alarm counter that records how many times the panel has been in alarm state.
  • Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
  • An integral EN54-4/A2 switch mode power supply.
  • Adjustable contamination levels.
  • Earth fault monitoring.
  • Combined keypad / keyswitch entry to Access Levels 2 and 3.
  • 999 event monitoring.
  • An intuitive Windows based upload-download PC program.
  • Optional flush-mounting bezel and glazed stainless steel enclosure also available.
  • Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
£717.90EX VAT
Add to Cart

XFP 2 loop 32Z panel Hochiki

SKU: XFP502/H
  • Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
  • Compatibility with Apollo’s XP95/Discovery protocol.
  • Two independently programmable conventional sounder circuits.
  • Two programmable inputs.
  • A fault output relay and three programmable relay outputs with voltage free changeover contacts.
  • A selection of zone dependency/coincidence functions.
  • A day/night (building occupied/unoccupied) function.
  • An investigation delay period function.
  • Phased evacuation facility.
  • An alarm counter that records how many times the panel has been in alarm state.
  • Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
  • An integral EN54-4/A2 switch mode power supply.
  • Adjustable contamination levels.
  • Earth fault monitoring.
  • Combined keypad / keyswitch entry to Access Levels 2 and 3.
  • 999 event monitoring.
  • An intuitive Windows based upload-download PC program.
  • Optional flush-mounting bezel and glazed stainless steel enclosure also available.
  • Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
£728.90EX VAT
Add to Cart

XFP 2 loop 32Z CAST

SKU: XFP502/CA

C-TEC XFP502/CA XFP 2 loop 32 Zone Panel, C-TEC CAST. Max. 2 x 7Ah batteries

C-TEC’s tried and trusted XFP two loop 32 zone addressable fire alarm panel – now available with C-TEC’s own digital fire alarm system protocol, CAST and fully certified to EN54 parts 2, 4 & 13.

With two powerful 40V 450mA loop drivers allowing the connection of up to 255 CAST devices per loop, the installation of a robust, feature-packed addressable fire alarm system has never been easier.

Protocol Features

‘CAST’ is the world’s most-advanced ‘distributed intelligence’ fire alarm system protocol. Conceived, designed and realised by C-TEC as part of a five-year, multi-million pound project, it involved the creation of a powerful proprietary communication protocol (C-TEC Addressable System Technology, CAST) and multiple control panels & field devices. Key features include:

• 255 devices per loop.

• Autonomous decision-making for faster response times.

• Multiple type codes.

• 40V loop drive voltage.

• Two ‘soft’ addressing options – automatic via the panel or manual via a powerful handheld programmer.

• Powerful multi-level addressing facilitates easy device addition and swapped device identification.

• Multiple functionality at a single address (integrated devices) – due 2021.

• Volumes, tones & detector modes can be changed at compatible panels.

• High-speed data transmission and robust data transfer.

• Provides geographical location of short and open circuit faults (a short circuit isolator is included as standard in every CAST field device).

• Replace device function.

• Programmable multi-function status LED.

• Future seamless integration with other CAST life safety systems reducing energy, servicing, installation and repair costs.

• ENVISION Enabled – fully compliant with our new ENVISION Cloud-based Fire ‘IoT’ Remote Access, System Test and Site Management software package.

• Designed and manufactured in the UK.

Panel Features

• Certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB) and EN54-13 by Kiwa Telefication.

• Two independently programmable conventional sounder circuits.

• Two programmable inputs.

• A fault output relay and three programmable relay outputs with voltage free changeover contacts.

• A selection of zone dependency/coincidence functions.

• A day/night (building occupied/unoccupied) function.

• An investigation delay period function.

• Phased evacuation facility.

• An alarm counter that records how many times the panel has been in alarm state.

• Powerful short circuit protected loop drivers.

• An integral EN54-4/A2 switch mode.

• Adjustable contamination levels.

• Earth fault monitoring.

• Combined keypad / keyswitch entry to Access Levels 2 and 3.

• 500 event monitoring.

• An intuitive Windows based upload-download PC program.

• Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.

 

£576.90EX VAT
Add to Cart

XFP 1 loop 32Z panel XP95/D

SKU: XFP501/X
  • Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
  • Compatibility with Apollo’s XP95/Discovery protocol.
  • Two independently programmable conventional sounder circuits.
  • Two programmable inputs.
  • A fault output relay and three programmable relay outputs with voltage free changeover contacts.
  • A selection of zone dependency/coincidence functions.
  • A day/night (building occupied/unoccupied) function.
  • An investigation delay period function.
  • Phased evacuation facility.
  • An alarm counter that records how many times the panel has been in alarm state.
  • Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
  • An integral EN54-4/A2 switch mode power supply.
  • Adjustable contamination levels.
  • Earth fault monitoring.
  • Combined keypad / keyswitch entry to Access Levels 2 and 3.
  • 999 event monitoring.
  • An intuitive Windows based upload-download PC program.
  • Optional flush-mounting bezel and glazed stainless steel enclosure also available.
  • Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
£520.90EX VAT
Add to Cart

XFP 1 loop 32Z panel Hochiki

SKU: XFP501/H
  • Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
  • Compatibility with Apollo’s XP95/Discovery protocol.
  • Two independently programmable conventional sounder circuits.
  • Two programmable inputs.
  • A fault output relay and three programmable relay outputs with voltage free changeover contacts.
  • A selection of zone dependency/coincidence functions.
  • A day/night (building occupied/unoccupied) function.
  • An investigation delay period function.
  • Phased evacuation facility.
  • An alarm counter that records how many times the panel has been in alarm state.
  • Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
  • An integral EN54-4/A2 switch mode power supply.
  • Adjustable contamination levels.
  • Earth fault monitoring.
  • Combined keypad / keyswitch entry to Access Levels 2 and 3.
  • 999 event monitoring.
  • An intuitive Windows based upload-download PC program.
  • Optional flush-mounting bezel and glazed stainless steel enclosure also available.
  • Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
£521.90EX VAT
Add to Cart

XFP 1 loop 16Z panel XP95/D

SKU: XFP501E/X
  • Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
  • Compatibility with Apollo’s XP95/Discovery protocol.
  • Two independently programmable conventional sounder circuits.
  • Two programmable inputs.
  • A fault output relay and three programmable relay outputs with voltage free changeover contacts.
  • A selection of zone dependency/coincidence functions.
  • A day/night (building occupied/unoccupied) function.
  • An investigation delay period function.
  • Phased evacuation facility.
  • An alarm counter that records how many times the panel has been in alarm state.
  • Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
  • An integral EN54-4/A2 switch mode power supply.
  • Adjustable contamination levels.
  • Earth fault monitoring.
  • Combined keypad / keyswitch entry to Access Levels 2 and 3.
  • 999 event monitoring.
  • An intuitive Windows based upload-download PC program.
  • Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
£447.90EX VAT
Add to Cart

XFP 1 loop 16Z panel Hochiki

SKU: XFP501E/H
  • Third-party certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB).
  • Compatibility with Apollo’s XP95/Discovery protocol.
  • Two independently programmable conventional sounder circuits.
  • Two programmable inputs.
  • A fault output relay and three programmable relay outputs with voltage free changeover contacts.
  • A selection of zone dependency/coincidence functions.
  • A day/night (building occupied/unoccupied) function.
  • An investigation delay period function.
  • Phased evacuation facility.
  • An alarm counter that records how many times the panel has been in alarm state.
  • Powerful short circuit protected loop drivers, capable of supporting up to 40 loop powered 10mA sounders per loop.
  • An integral EN54-4/A2 switch mode power supply.
  • Adjustable contamination levels.
  • Earth fault monitoring.
  • Combined keypad / keyswitch entry to Access Levels 2 and 3.
  • 999 event monitoring.
  • An intuitive Windows based upload-download PC program.
  • Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.
£383.90EX VAT
Add to Cart

XFP 1 loop 16Z CAST

SKU: XFP501E/CA

C-TEC XFP501E/CA XFP 1 Loop 16 Zone Panel, C-TEC CAST. Max. 2 x 3.2Ah Batteries

C-TEC’s tried and trusted XFP one loop 16 zone addressable fire alarm panel – now available with C-TEC’s own digital fire alarm system protocol, CAST and fully certified to EN54 parts 2, 4 and 13.

With a powerful 40V 500mA loop driver allowing the connection of up to 255 CAST devices, the installation of a cost-effective, feature-packed addressable fire alarm system has never been easier.

Protocol Features

‘CAST’ is the world’s most-advanced ‘distributed intelligence’ fire alarm system protocol. Conceived, designed and realised by C-TEC as part of a five-year, multi-million pound project, it involved the creation of a powerful proprietary communication protocol (C-TEC Addressable System Technology, CAST) and multiple control panels & field devices. Now available to purchase.

Key Features

• 255 devices per loop.

• Autonomous decision-making for faster response times.

• Multiple type codes.

• 40V loop drive voltage.

• Two ‘soft’ addressing options – automatic via the panel or manual via a powerful handheld programmer.

• Powerful multi-level addressing facilitates easy device addition and swapped device identification.

• Multiple functionality at a single address (integrated devices) – due 2021.

• Volumes, tones & detector modes can be changed at compatible panels.

• High-speed data transmission and robust data transfer.

• Provides geographical location of short and open circuit faults (a short circuit isolator is included as standard in every CAST field device).

• Replace device function.

• Programmable multi-function status LED.

• Future seamless integration with other CAST life safety systems reducing energy, servicing, installation and repair costs.

• ENVISION Enabled – fully compliant with our new ENVISION Cloud-based Fire ‘IoT’ Remote Access, System Test and Site Management software package.

• Designed and manufactured in the UK.

Panel Features

• Certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB) and EN54-13 by Kiwa Telefication.

• Two independently programmable conventional sounder circuits.

• Two programmable inputs.

• A fault output relay and three programmable relay outputs with voltage free changeover contacts.

• A selection of zone dependency/coincidence functions.

• A day/night (building occupied/unoccupied) function.

• An investigation delay period function.

• Phased evacuation facility.

• An alarm counter that records how many times the panel has been in alarm state.

• Powerful short circuit protected loop drivers.

• An integral EN54-4/A2 switch mode.

• Adjustable contamination levels.

• Earth fault monitoring.

• Combined keypad / keyswitch entry to Access Levels 2 and 3.

• 500 event monitoring.

• An intuitive Windows based upload-download PC program.

• Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.

 

£313.90EX VAT
Add to Cart

XFP 1 loop 32Z CAST

SKU: XFP501/CA

C-TEC XFP501/CA XFP 1 loop 32 Zone Panel, C-TEC CAST. Max. 2 x 7Ah Batteries

C-TEC’s tried and trusted XFP one loop 32 zone addressable fire alarm panel – now available with C-TEC’s own digital fire alarm system protocol, CAST and fully certified to EN54 parts 2, 4 and 13.

With a powerful 40V 450mA loop driver allowing the connection of up to 255 CAST devices, the installation of a robust, feature-packed addressable fire alarm system has never been easier.

Protocol Features

‘CAST’ is the world’s most-advanced ‘distributed intelligence’ fire alarm system protocol. Conceived, designed and realised by C-TEC as part of a five-year, multi-million pound project, it involved the creation of a powerful proprietary communication protocol (C-TEC Addressable System Technology, CAST) and multiple control panels & field devices.

Key Features

• 255 devices per loop.

• Autonomous decision-making for faster response times.

• Multiple type codes.

• 40V loop drive voltage.

• Two ‘soft’ addressing options – automatic via the panel or manual via a powerful handheld programmer.

• Powerful multi-level addressing facilitates easy device addition and swapped device identification.

• Multiple functionality at a single address (integrated devices) – due 2021.

• Volumes, tones & detector modes can be changed at compatible panels.

• High-speed data transmission and robust data transfer.

• Provides geographical location of short and open circuit faults (a short circuit isolator is included as standard in every CAST field device).

• Replace device function.

• Programmable multi-function status LED.

• Future seamless integration with other CAST life safety systems reducing energy, servicing, installation and repair costs.

• ENVISION Enabled – fully compliant with our new ENVISION Cloud-based Fire ‘IoT’ Remote Access, System Test and Site Management software package.

• Designed and manufactured in the UK.

Panel Features

• Certified to EN54-2/4 by the Loss Prevention Certification Board (LPCB) and EN54-13 by Kiwa Telefication.

• Two independently programmable conventional sounder circuits.

• Two programmable inputs.

• A fault output relay and three programmable relay outputs with voltage free changeover contacts.

• A selection of zone dependency/coincidence functions.

• A day/night (building occupied/unoccupied) function.

• An investigation delay period function.

• Phased evacuation facility.

• An alarm counter that records how many times the panel has been in alarm state.

• Powerful short circuit protected loop drivers.

• An integral EN54-4/A2 switch mode.

• Adjustable contamination levels.

• Earth fault monitoring.

• Combined keypad / keyswitch entry to Access Levels 2 and 3.

• 500 event monitoring.

• An intuitive Windows based upload-download PC program.

• Up to eight XFP main panels (any variant) can be connected onto a two-wire RS485 non-redundant network. Alternatively, up to eight XFP repeaters can be connected to any non-networked main panel.

£457.90EX VAT
Add to Cart

Full colour screen IP paging console PPM-IT5

SKU: PPM-IT5
  • Voltage:18 – 26 VDC
  • Power consumption:250 mA
  • Frequency response:-3 dB @ 200 Hz to 8 kHz
  • THD:< 1% @ 1 kHz
  • Output impedance:100 Ω
£1,490.90EX VAT
Add to Cart

24 Port Cat 5e Patch Panel PNL24AB

SKU: PNL24AB

24 Port Cat 5e Patch Panel

The Allrack 24 port Cat 5e patch panel offers Category 5e performance when installed using uTP Cat 5e cable. This 1u high patch panel fits all 19″ cabinets and racks. IDC rear termination, RJ45 socket presention on front of panel.

£20.90EX VAT
Add to Cart

1U 4 Ring Management Bar MANBAR1U4R

SKU: MANBAR1U4R

1U 4 x 65mm Ring Management Bar

£4.90EX VAT
Add to Cart

Security system control panel with support for photo verification & LTE cellular module HUB2-WHITE-4G

SKU: HUB2-WHITE-4G


 

Security system control panel with support for photo verification & LTE cellular module

Spare accessories available (likely on a special order basis), if required please speak to Sales or your BDM.

In control of security, not your private life

Hub 2 manages all the Ajax devices in the system to alert users about open doors, broken windows, threats of fire and flooding. If burglars break into your facility, Hub 2 will notify the monitoring station 1and send photos from the MotionCam detectors. You won’t need to live under the constant supervision of the security cameras to know what’s going on.

Alarm photo verification in 9 seconds

Hub 2 works with MotionCam and MotionCam Outdoor motion detectors. When detectors are triggered, they take a series of photos. It helps to evaluate the situation at the facility. Visual verification helps you instantly assess the situation, relieving users of unnecessary anxiety, and security companies — from false calls of patrols.

Always connected — via cable and cellular networks

Communication with the outside world is critical for the security system control panel. Its reliability and stability guarantee timely alarm transmission to the security company and users.

Hub 2 can be simultaneously connected to three Internet service providers — via Ethernet cable and 2G, 3G, and LTE 2 cellular networks. The automatic switching between channels takes seconds.

Guaranteed delivery of alarms and visual alarm verifications

To ensure reliable communications, we have equipped Hub 2 with four antennas and support of two proprietary radio protocols: Jeweller and Wings. Jeweller is responsible for the transmission of commands, events, and alarms, while Wings provides batch transmission of images. Ajax two-way radio communication uses frames to synchronize device communication sessions, authentication to prevent fraud, and encryption to protect against data theft.

Flexibility at the core

The Hub 2 radio network covers several floors and separate buildings — thanks to the communication range of 2,000 meters and the ability to connect five range extenders. To manage access and security zoning of the facility, the hub allows connecting 50 users and creating 9 security groups. Hub 2 is a perfect choice for home and business security.

Controlled with apps

We refrained from control buttons on the control panel body and archaic interfaces — apps are more convenient and reliable. They connect to a hub via a secure channel through the Ajax Cloud server located in several AWS data centres. Server availability in 2021 was 99.995%.

Apps allow system users with administrator rights to manage the security of the facility, change settings of the hub and the devices connected to it, create scenarios, and monitor events. From a smartphone or a PC. On the site and remotely.

Automates security

Hub 2 allows creating 32 scenarios and minimizing the impact of human factor on security. The hub can arm and disarm a facility or a group by schedule. Instantly activate a smoke machine if someone enters the premises. Blackout the premises and turn on emergency lighting in case of fire. Or shut off the water in case of a leak. Control lights, electric locks, roller shutters, and garage doors — by arming/disarming, button press, or a detector alarm.
 

Resistant to sabotage

Whatever happens to Hub 2, the security company and the users will be notified. No one can disconnect the hub unnoticed when the facility is disarmed. If an intruder attempts to dismount the device, this will trigger the tamper immediately. The Ajax Cloud server can notify about the loss of connection with the hub in 60 seconds due to frequent polling. Even if the building is de-energized, the hub will protect the object for up to 16 hours with a built-in backup battery.

Future-proof

Hub 2 runs OS Malevich — a real-time operating system developed by Ajax Systems. OS Malevich is extremely stable, immune to viruses, and protected from cyberattacks. Modular architecture simplifies the constant upgrading of OS Malevich.

Hub receives new features several times a year with over-the-air updates. The update process is automatic and takes minutes when the security system is disarmed. The hardware configuration will allow Hub 2 to evolve and remain relevant for years to come.

Hassle-free installation

Hub 2 is ready to operate out of the box. All communication modules, power supply, and backup battery are already installed. To start setting up the system, you need to connect the device to the power supply and the Internet, insert the SIM cards, and scan the QR code through the app. With the SmartBracket mounting panel, there is no need to disassemble the device body during installation.

Connecting security devices, video cameras, users, testing the radio signal, creating groups and scenarios, even sending a request for connection to the CMS — all system settings are always available in the Ajax apps. Whether you are at the site or not.

Easy security system upgrade

To simplify updating hubs at the facilities, we have provided the ability to transfer data between them automatically. The import feature allows you to transfer settings, connected devices, groups, scenarios, and users from the old hub to Hub 2. In less than 15 minutes.
 
£173.90EX VAT
Add to Cart

Radio signal range extender supporting photo verification of alarms REX2-WHITE

SKU: REX2-WHITE

 


Spare accessories available (likely on a special order basis), if required please speak to Sales or your BDM.

 

More applications of a security system 

Range extenders expand the boundaries of the protected area and give even more freedom to place security system devices. By connecting all or part of the devices 1 to ReX 2, you will ensure the security and automation of a business centre, estate, warehouse complex, or a large production facility.

5 range extenders can operate within the Ajax system to expand the coverage of the radio network up to 35 km2 2. Events and alarms are transmitted instantly, and the first photo verification snapshot is delivered to a monitoring station and users in just 13 seconds

Verification of alarms with snapshots

ReX 2 works with MotionCam and MotionCam Outdoor motion detectors. When triggered, they take a series of shots, helping to evaluate the events at a facility. Visual verification helps to instantly ascertain the situation, saving users from concerns and security companies from unnecessary patrol dispatches.

Guaranteed delivery of alarms and visual alarm verifications

To ensure reliable communications, we have equipped ReX 2 with four antennas and support of two proprietary radio protocols: Jeweller and Wings. Jeweller is responsible for the transmission of commands, events, and alarms, while Wings provides batch transmission of images. Ajax two-way radio communication uses frames to synchronize device communication sessions, authentication to prevent fraud, and encryption to protect against data theft. 

Radio communication through steel and concrete 

The next major OS Malevich update allows covering office centres with underground parking lots, sectional metal hangars, and warehouse complexes of several large buildings with a single Ajax system. Once the operating system is updated, ReX 2 will be able to connect to a hub both via radio communication and via Ethernet 4 — using the wire as a single or second communication channel.

Enhanced security system

ReX 2 works as an extra intelligent control panel: it connects devices into an autonomous group and takes over control at the right time. Thanks to automatic adjustment of signal strength and frame synchronization, any number of system devices can be connected to ReX 2 — the reliability of communication will not be affected by this. If, for some reason, radio communication with the hub is interrupted, ReX 2 will receive an alarm from a sensor and activate a siren to draw attention to the incident and deter the burglar.

Ready to resist intruder attacks

ReX 2 is protected from attacks at the software and hardware levels. It runs on the OS Malevich operating system, which is immune to viruses. All data transmitted by the range extender is encrypted. Thanks to the built-in backup battery, a sudden blackout at a facility will not be a problem.

Hassle-free installation

ReX 2 connection and configuration process saves the installation engineer time as much as possible. To add a range extender to a system, simply scan a QR-code with the Ajax app and assign it a name and a room. The device is also configured in real time in the app. If necessary, ReX 2 can be disabled or reconfigured without site visits.

 

  1. ReX 2 cannot be connected to another range extender, only to a hub.
  2. If five radio signal range extenders are used in the system.
  3. When transmitting images from MotionCam Outdoor (default settings) through ReX 2 range extender and the hub. The hub should be connected to the internet via Ethernet, Wi-Fi, or LTE. Delivery time with other resolution settings is available via link
  4. ReX 2 is equipped with an Ethernet port, but the functionality will become available with the OS Malevich update.

 

£119.90EX VAT
Add to Cart

Intelligent control panel with visual alarm verification HUB2-WHITE

SKU: HUB2-WHITE
  • Device polling period from 12 seconds
  • Detection connection loss with a hub in 60 seconds
  • Operation on backup battery up to 15 hours
£207.90EX VAT
Add to Cart

Radio signal range extender supporting photo verification of alarms REX2-BLACK

SKU: REX2-BLACK

 


 

More applications of a security system 

Range extenders expand the boundaries of the protected area and give even more freedom to place security system devices. By connecting all or part of the devices 1 to ReX 2, you will ensure the security and automation of a business centre, estate, warehouse complex, or a large production facility.

5 range extenders can operate within the Ajax system to expand the coverage of the radio network up to 35 km2 2. Events and alarms are transmitted instantly, and the first photo verification snapshot is delivered to a monitoring station and users in just 13 seconds

Verification of alarms with snapshots

ReX 2 works with MotionCam and MotionCam Outdoor motion detectors. When triggered, they take a series of shots, helping to evaluate the events at a facility. Visual verification helps to instantly ascertain the situation, saving users from concerns and security companies from unnecessary patrol dispatches.

Guaranteed delivery of alarms and visual alarm verifications

To ensure reliable communications, we have equipped ReX 2 with four antennas and support of two proprietary radio protocols: Jeweller and Wings. Jeweller is responsible for the transmission of commands, events, and alarms, while Wings provides batch transmission of images. Ajax two-way radio communication uses frames to synchronize device communication sessions, authentication to prevent fraud, and encryption to protect against data theft. 

Radio communication through steel and concrete 

The next major OS Malevich update allows covering office centres with underground parking lots, sectional metal hangars, and warehouse complexes of several large buildings with a single Ajax system. Once the operating system is updated, ReX 2 will be able to connect to a hub both via radio communication and via Ethernet 4 — using the wire as a single or second communication channel.

Enhanced security system

ReX 2 works as an extra intelligent control panel: it connects devices into an autonomous group and takes over control at the right time. Thanks to automatic adjustment of signal strength and frame synchronization, any number of system devices can be connected to ReX 2 — the reliability of communication will not be affected by this. If, for some reason, radio communication with the hub is interrupted, ReX 2 will receive an alarm from a sensor and activate a siren to draw attention to the incident and deter the burglar.

Ready to resist intruder attacks

ReX 2 is protected from attacks at the software and hardware levels. It runs on the OS Malevich operating system, which is immune to viruses. All data transmitted by the range extender is encrypted. Thanks to the built-in backup battery, a sudden blackout at a facility will not be a problem.

Hassle-free installation

ReX 2 connection and configuration process saves the installation engineer time as much as possible. To add a range extender to a system, simply scan a QR-code with the Ajax app and assign it a name and a room. The device is also configured in real time in the app. If necessary, ReX 2 can be disabled or reconfigured without site visits.

 

  1. ReX 2 cannot be connected to another range extender, only to a hub.
  2. If five radio signal range extenders are used in the system.
  3. When transmitting images from MotionCam Outdoor (default settings) through ReX 2 range extender and the hub. The hub should be connected to the internet via Ethernet, Wi-Fi, or LTE. Delivery time with other resolution settings is available via link
  4. ReX 2 is equipped with an Ethernet port, but the functionality will become available with the OS Malevich update.

 

£119.90EX VAT
Add to Cart

CFP Standard 4 zone panel CFP704-4

SKU: CFP704-4
  • Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13 compliance from the BSI.
  •  

  • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
  •  

  • Manufactured by C-TEC in the UK.
  •  

  • Two detector zone circuits.
  •  

  • Four conventional sounder circuits
  •  

  • Integral 1.5A EN54-4/A2 compliant switch mode PSU.
  •  

  • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
  •  

  • Two on-board relays (Fire and Fault).
  •  

  • Two open-collector outputs (Remote and Reset).
  •  

  • ‘Class change’ and alert inputs.
  •  

  • Installer-friendly design.
  •  

  • Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
  •  

  • Low 25mA quiescent current.
  •  

  • Multiple indicators.
  •  

  • System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
  •  

  • Space for two x 12V 3.3Ah VRLA batteries.
  •  

  • Fully compatible with C-TEC’s ActiV range of conventional fire detectors.
£108.90EX VAT
Add to Cart