Ethernet Cables

Ethernet cables carry network data between switches, routers, computers, cameras and wall outlets over twisted copper pairs terminated in RJ45 plugs. This collection holds ready-made patch leads in Cat5, Cat5e, Cat6, Cat6a and Cat7 from AV:Link, Haydon and Knightsbridge, plus 305m and 100m installation reels from Mercury and SFX Cables, including LSZH, shielded and black outdoor cable for runs through walls, ceilings and between buildings.

Choosing Ethernet Cables

Choose an Ethernet cable by its category, by whether you need a finished lead or bulk cable to terminate yourself, and by where the run goes.

Category and speed

Cat5e and Cat6 are the everyday choices for Gigabit Ethernet. Mercury Cat6 reels such as the 808.011UK pass a Fluke test at 250MHz over 100m, where the Cat5e 808.001UK passes at 100MHz. For 10Gbps, move to Cat6a or Cat7: the AV:Link Cat6a flat leads are rated 500MHz and the Cat7 S/FTP leads 600MHz.

Patch leads or bulk cable

Patch leads arrive with RJ45 plugs fitted, ready to connect a device to a switch, router or wall outlet; the AV:Link 113.146UK Cat6 lead uses stranded copper and snag-less boots. Reels such as the Mercury 808.011UK hold 305m of solid-conductor cable, marked at 1m intervals, for permanent runs terminated at patch panels and outlets.

Conductor and sheath

Most Mercury reels use oxygen-free copper (OFC), while the economy 808.021UK and 808.025UK use copper clad aluminium (CCA), as do the AV:Link Cat5e leads. LSZH sheaths, on reels such as the 808.015UK, limit smoke and fumes in a fire, and black LDPE-sheathed cable such as the 808.041UK is UV resistant for outdoor installations.

CategoryExampleRating
Cat5eMercury 808.001UK, 305m reel100MHz Fluke tested
Cat6AV:Link 113.136UK, 5.0m lead250 MHz, 1 Gbps
Cat6aMercury 808.032UK, 305m reel500MHz Fluke tested
Cat7AV:Link 113.710UK, 10m lead10Gbps, S/FTP
Cat6 outdoorMercury 808.041UK, 305m reelLDPE sheath, black

Lengths and colours

AV:Link Cat6 and Cat5e leads are grey and run from 0.5m to 30m. Its Cat7 leads run from 1m to 20m and most are black, and its Cat6a flat leads run from 1.5m to 10m and most are white. Haydon Cat5 and Cat5e leads come in blue, grey, red and black, and Mercury reel sheaths include grey, lilac, red, green and orange.

Brands we stock in Ethernet Cables

AV:Link, Connectix Cabling Systems, Haydon, Knightsbridge, Mercury and SFX Cables.

AV:Link supplies the most products, followed by Mercury.

Related categories

Connect leads to network switches and PoE, terminate bulk cable at patch panels and RJ45 connectors, prove finished runs with cable testers and fault finders, or browse network cables and accessories and our Help & Support guides.

Frequently asked questions

What is the difference between Cat5e and Cat6 cable?

Cat6 is tested to a higher frequency. Mercury Cat6 reels such as the 808.011UK pass a Fluke test at 250MHz over 100m, where Cat5e reels such as the 808.001UK pass at 100MHz. The 808.011UK and 808.001UK both suit Gigabit Ethernet applications. For 10Gbps networks, choose Cat6a or Cat7 instead.

Which cable do I need for 10 Gigabit Ethernet?

Cat6a or Cat7. The AV:Link Cat6a flat leads, such as the 113.733UK, support 500MHz and 10Gbps, and the Cat7 S/FTP leads, such as the 113.705UK, 600MHz and 10Gbps. For installed runs, the Mercury 808.032UK Cat6a reel passes a Fluke test at 500MHz over 100m, and the 808.050UK Cat7 reel is rated for 10 Gbps at 600MHz.

What is an Ethernet cable?

An Ethernet cable such as the Mercury 808.011UK is a twisted pair data cable for high-speed data transmission, including Gigabit Ethernet. For example, the 808.011UK is 305m of Cat6 cable with a solid copper conductor, marked at 1m intervals and supplied in a dispensing box, while the AV:Link 113.146UK is a 30m Cat6 RJ45 patch lead for PCs, printers, servers, routers and switch boxes at up to 1Gbps.

Can I run Ethernet cable outside?

Yes, with cable made for it. The Mercury 808.010UK Cat5e, 808.041UK Cat6 and 808.034UK Cat6a outdoor reels have a black LDPE sheath with UV resistant properties for outdoor installations. Check the sheath before running any other cable outside: the SFX Cat5e LSZH reel, for example, is recommended for internal use.

What is LSZH network cable?

LSZH means low smoke zero halogen, a sheath material that minimises the risk of thick black smoke and poisonous fumes if the cable is caught in a fire. Mercury LSZH reels include the 808.005UK Cat5e, 808.015UK Cat6, 808.031UK Cat6a and 808.050UK Cat7, and SFX Cables supplies Cat5e and Cat6A LSZH reels on 305m.

What is the difference between CCA and copper network cable?

CCA (copper clad aluminium) is an aluminium conductor with a copper coating, while OFC cable uses oxygen-free copper. The Mercury economy reels, the 808.021UK Cat5e and 808.025UK Cat6, are solid CCA, and its other reels are oxygen-free or pure copper. The AV:Link Cat5e patch leads and the Knightsbridge NETC61M and NETC63M are CCA.

What do U/UTP, F/UTP, U/FTP and S/FTP mean?

They describe the screening. U/UTP has no screen, F/UTP adds an overall foil around the pairs, U/FTP a foil on the individual pairs, and S/FTP individual pair foils inside an overall braid. The Mercury 808.033UK Cat6a S/FTP suits Gigabit Ethernet in noisy environments, where crosstalk and interference are a concern.

How long can an Ethernet cable run be?

Plan copper Ethernet runs to 100m, the distance over which Mercury reels such as the 808.011UK are Fluke tested. Beyond that, add a switch or an extender part way along the run. Patch leads here reach 30m, with the AV:Link Cat6 113.146UK and Cat5e 113.166UK at that length.

What is a flat Ethernet cable for?

A flat cable suits narrow spaces where a round lead is awkward to route. The AV:Link Cat6a FTP flat leads, such as the 113.733UK at 3m, have a low-profile flat design, pure copper 30AWG conductors and FTP shielding, and carry 10Gbps. Most are white, and lengths run from 1.5m to 10m.

Why buy from West Midlands Electrics

  • Established 1975
  • Birmingham trade counter
  • UK-only supply

Written by the West Midlands Electrics technical team