Apollo Fire Detection & Alarm Equipment
Apollo makes fire detection devices for addressable and conventional fire alarm systems, and this page lists its range: XP95, Discovery and Orbis smoke, heat and multisensor detectors, AlarmSense two-wire devices, flame and beam detectors, detector and sounder bases, open-area sounders and visual alarm devices, interface and switch monitor modules, and accessories such as address cards, call point covers and reset keys.
Apollo XP95 Heat Detector, Fixed Temp A2S 55°C, Addressable, White, 55000-420APO
55°C Alarm£ 28 54RRP: £30.67Fast delivery Tomorrow, 21 Oct
Choosing Apollo Fire Detection & Alarm Equipment
Start with the fire panel: XP95 and Discovery devices sit on an addressable loop, while AlarmSense devices run on a two-wire conventional circuit.
Detectors
Optical smoke detectors such as the Discovery 58000-600APO use a light-scatter chamber to pick up slow-burning and smouldering fires, with five selectable response modes. Where smoke detection is unsuitable, heat detectors respond to temperature instead: the XP95 55000-400APO alarms at about 55°C, and the 55000-401APO at 90°C suits car parks, loading bays and kitchens. Multisensors such as the 55000-885APO combine photo-electric smoke and thermistor heat sensing to reduce nuisance alarms. For special risks, the 55000-020APO flame detector senses the flickering infra-red of flames, and the SA7100-100APO is an auto-aligning reflective beam detector.
Sounders and visual alarms
The 55000-001APO open-area sounder is loop-powered on an isolating 4" base, with selectable tones and volume settings of 92 dB(A) and 100 dB(A). Sounder VAD bases such as the 45681-705APO combine a sounder and a white-flash visual alarm device with a built-in isolator. Where tones may be masked by background noise, or to alert hearing-impaired people, VADs give a 0.5 Hz white flash: the 55000-744APO for walls (EN 54-23 W-2.4-6) and the 55000-745APO for ceilings (Category C).
| Need | Example | Detail |
|---|---|---|
| Addressable smoke | 58000-600APO | Discovery, optical, EN54-7 |
| Heat in a dusty area | 55000-400APO | XP95, fixed 55°C |
| Loop sounder | 55000-001APO | 92/100 dB(A), isolating base |
| Ceiling visual alarm | 55000-745APO | EN 54-23 Category C, 0.5 Hz |
| Conventional smoke | 55000-390APO | AlarmSense two-wire, EN54-7 |
Bases, modules and accessories
The XPERT 7 isolating base 45681-284APO automatically isolates short-circuit faults on loops and spurs, and XPERT address cards such as the 45682-800APO set a detector address by removing numbered pips. Modules link other equipment to the loop: the SA4700-102APO supervises volt-free contacts and switches changeover relay outputs, and the 55000-760APO mini switch monitor mounts on a 35 mm DIN rail. The 55000-982APO electromagnetic door holder connects directly to the addressable loop, so the panel can close fire doors in alarmed areas.
Related categories
By type, see Apollo smoke detectors, Apollo heat detectors, Apollo call points and Apollo sounders. Other makes are in fire detectors, fire alarm sounders and beacons and commercial fire alarm panels. Our Help & Support guides cover fire alarm planning.
Frequently asked questions
Should I fit an Apollo heat detector or a smoke detector?
Fit a smoke detector wherever it will not be set off by normal conditions, and a heat detector where dust, fumes or steam would cause false alarms. The Discovery 58000-600APO suits hotels, offices, care homes and escape routes. The XP95 55000-401APO heat detector alarms at 90 °C and is made for dusty, smoky or high-airflow areas such as car parks, loading bays, kitchens and warehouses.
What does AlarmSense mean in the Apollo range?
AlarmSense is Apollo’s two-wire conventional fire system, where detectors and sounders share a polarity-insensitive, monitored two-wire circuit. The 55000-390APO is an EN54-7 AlarmSense optical smoke detector for bedrooms, escape routes, care homes and HMOs. The 55000-017APO sounder VID synchronises its tone and flash with other AlarmSense devices, and the 55000-835APO relay module drives auxiliary devices such as door releases.
What does an Apollo isolating base do?
An isolating base detects a short circuit on the loop or spur and automatically isolates it, to reduce disruption to the rest of the fire alarm loop. The XPERT 7 45681-284APO is an isolating detector base for XP95 and Discovery detectors. The 55000-001APO open-area sounder is supplied on an isolating 4" base, and the 45681-705APO sounder VAD base has an integral isolator.
How are Apollo call points tested without breaking the glass?
Apollo XP95 manual call points are operated and reset with a plastic reset/test key, so routine tests do not break the glass element. The 44251-176APO is a pack of 10 keys for the new style XP95 reset mechanism. The 44251-189APO transparent hinged cover clips onto a single Apollo call point and must be lifted before use, which reduces accidental or malicious activations.
Why buy from West Midlands Electrics
- Established 1975
- Birmingham trade counter
- UK-only supply
Updated