Apollo Heat Detectors
An Apollo heat detector is a fire alarm detector that responds to temperature rather than smoke, for places where smoke detection would give false alarms. This collection covers Apollo heat detectors across XP95, Series 65, Orbis, AlarmSense, REACH Wireless and XPander, in fixed-temperature, rate-of-rise, high-temperature, marine and intrinsically safe versions, plus multi-sensor heads and an Orbis heated base for cold and damp locations.
Apollo XP95 Heat Detector, Fixed Temp A2S 55°C, Addressable, White, 55000-420APO
55°C Alarm£ 28 54RRP: £30.67Fast delivery Wed, 04 NovApollo Series 65 Heat Detector, Class CS, 80°C Application 55000-137APO
£ 13 91RRP: £16.69Apollo Series 65 Heat Detector, Class BR, 65°C Application 55000-127APO
£ 13 91RRP: £16.69
Choosing Apollo Heat Detectors
Choose the Apollo range your panel uses, then the heat response the location needs.
Fixed temperature or rate of rise
Fixed-temperature detectors alarm at a set point: the XP95 55000-400APO and 55000-420APO at 55°C (A2S), and high-temperature CS versions such as the XP95 55000-401APO at 90°C and the AlarmSense 55000-193APO at 84°C. Rate-of-rise detectors such as the AlarmSense 55000-190APO (A1R) also respond to a rapid climb in temperature.
By system
XP95 heads report on an addressable loop, AlarmSense heads run on a two-wire system, and REACH Wireless RW1000-460APO and XPander heads communicate by radio.
Specialist environments
Orbis marine heat detectors, such as the ORB-HT-41001-MAR, are marine versions suited to environments that are dirty or smoky under normal conditions, and Orbis I.S. heat detectors, such as the ORB-HT-51145-APO, are the intrinsically safe versions; on the ORB-HT-51149-APO the operating temperature is restricted by the intrinsic safety gas classification. The Orbis ORB-HB-00020-APO heated base limits the risk of icing or condensation affecting detectors in cold places.
| Model | Range | Response |
|---|---|---|
| 55000-400APO | XP95 | Fixed 55°C (A2S) |
| 55000-401APO | XP95 | High temperature 90°C (CS) |
| 55000-190APO | AlarmSense | Rate of rise (A1R) |
| ORB-HT-41001-MAR | Orbis | Marine |
| RW1000-460APO | REACH Wireless | Addressable wireless |
Standards & compliance
EN54-5 is the standard for point heat detectors, and it is cited on the AlarmSense 55000-193APO and 55000-190APO in this range.
Multi-sensor heads
The XP95 55000-885APO combines optical smoke and thermistor heat sensing, the Discovery 58000-305APO combines CO and heat, and the Orbis ORB-OH-13003-APO is a heat multi-sensor detector.
Related categories
For domestic and wireless heat detection see heat alarms, for the smoke side of a system smoke alarms and detectors, and Apollo's smoke heads in Apollo smoke detectors.
Frequently asked questions
Where should a heat detector be used instead of a smoke detector?
Heat detectors suit places where smoke, dust, steam or fumes would trigger a smoke detector, such as kitchens, plant rooms, car parks and loading bays, which the Apollo XP95 55000-401APO and AlarmSense 55000-193APO product descriptions name. They respond to temperature rather than smoke particles.
What is the difference between A1R and A2S heat detectors?
A1R and A2S are heat detector classes. An A2S detector, such as the Apollo XP95 55000-400APO, alarms at a fixed 55°C. An A1R detector, such as the AlarmSense 55000-190APO, combines a fixed upper limit with rate-of-rise monitoring, so a rapid temperature climb also triggers it.
What is a CS heat detector?
A CS detector is a high-temperature fixed heat detector for areas that run warm normally. The Apollo XP95 55000-401APO alarms at 90°C and the AlarmSense 55000-193APO at 84°C. The AlarmSense 55000-193APO head suits locations such as commercial kitchens, workshops and plant rooms.
What is an Apollo marine heat detector?
Orbis marine heat detectors, such as the ORB-HT-41001-MAR, ORB-HT-41002-MAR, ORB-HT-41003-MAR, ORB-HT-41004-MAR and ORB-HT-41006-MAR, are Apollo's conventional heat detectors for marine installations. They use a single thermistor to sense air temperature and are part of the Orbis Marine range of conventional fire detectors, suited to areas that are dirty or smoky under normal conditions.
What is an intrinsically safe heat detector?
An intrinsically safe (I.S.) heat detector is one whose use is governed by an intrinsic safety gas classification. The Apollo Orbis I.S. ORB-HT-51145-APO monitors temperature with a single thermistor network, and the ORB-HT-51149-APO states that its operating temperature is restricted by that classification, with Class T5 rated at +45°C and Class T4 at +60°C.
Can Apollo heat detectors be wireless?
Yes. The Apollo REACH Wireless RW1000-460APO is a wireless analogue addressable heat detector that can be configured as rate-of-rise or fixed temperature, and XPander heat detectors such as the XPA-CB-11170-APO measure the air temperature every 2 seconds and communicate by radio.
What is an Apollo Series 65 heat detector?
Series 65 is an Apollo heat detector range. Heads such as the 55000-122APO, 55000-126APO and 55000-132APO monitor temperature with a dual thermistor network, or a single thermistor on CS versions, and suit applications where smoke detectors are unsuitable. The 55000-126APO description also lists a flashing LED and a magnet-operated test switch option.
What is a heat multi-sensor detector?
A multi-sensor combines heat sensing with a second sensor. The Apollo XP95 55000-885APO pairs optical smoke with a thermistor, the Orbis ORB-OH-13003-APO is more sensitive than an optical detector to flaming fires, including liquid fires, and the Discovery 58000-305APO combines carbon monoxide with heat.
What is an Orbis heated base?
The Apollo ORB-HB-00020-APO is a heater base for cold climates, where icing or condensation could affect a detector. It raises the temperature of the detector chamber by about 10°C, and Apollo recommends pairing it with a waterproof base cover or deckhead mounting box.
Why buy from West Midlands Electrics
- Established 1975
- Birmingham trade counter
- UK-only supply