Google Top Quality Store · Rated Exceptional
View as

Fire Detector Testers

Fire detector testers are tools and consumables for checking that fire detection responds as it should. The collection holds Xtralis by Honeywell smoke pellets and a VESDA sampling test point, the C-TEC CAPROG programmer and tester for CAST addressable systems, a Honeywell Commercial Security remote test station for Li-ion Tamer gas sensors, and Kidde smoke pellets for Class C aspiration smoke detection systems.

Choosing Fire Detector Testers

A smoke detector tester is equipment for checking that smoke detection responds; the Xtralis by Honeywell 251-003, for example, is a pack of 6 smoke pellets that charge detectors with smoke for testing purposes and verification of air flow. Pick the tester that matches the detection system, whether aspirating or addressable.

Smoke pellets

The 251-003 and 1-21888-K030 smoke pellets burn for 40 seconds and produce 18 cubic metres of smoke per pellet. The Kidde 1-21888-K030 pellets are made for testing Class C aspiration smoke detection systems, and the Xtralis 251-003 pellets are lit with an open flame on a non-flammable base and burn to complete ash without forming flames.

Programming and testing CAST devices

The C-TEC CAPROG is a handheld device programmer and tester for C-TEC's CAST addressable fire alarm systems. The CAPROG assigns CAST detectors, manual call points, sounders, VADs and interface units a User ID, tests a device's outputs by switching on its sounder, VAD or relay, and shows when a smoked CAST detector has gone into alarm. It is battery powered with an auto shutdown feature and a backlit LCD, and its integrated base connects directly to CAST detectors and sounders.

Test points and gas sensor checks

The PIP-018 is a lightweight, chemical resistant sampling test point for VESDA systems, where small-bore capillary pipes give discreet detection, for example in heritage buildings. The LT-ACC-TST is a remote test station for the Li-ion Tamer Rack Monitor system that contains battery off-gassing compounds, so the gas sensors' response can be verified with a bump test.

Products at a glance

ModelMakerTypeUse
251-003Xtralis by HoneywellSmoke pellets, pack of 6Testing detectors and air flow
1-21888-K030KiddeSmoke pellets, pack of 6Class C aspiration systems
CAPROGC-TECDevice programmer and testerCAST addressable systems
PIP-018Xtralis by HoneywellSampling test pointVESDA capillary detection
LT-ACC-TSTHoneywell Commercial SecurityRemote test stationLi-ion Tamer gas sensor bump test

Related pages

See aspirating smoke detectors, fire detectors and manual call points.

Brands we stock in Fire Detector Testers

C-TEC, Honeywell Commercial Security, Kidde and Xtralis by Honeywell.

Frequently asked questions

What equipment is used to test a fire alarm system?

Testing a fire alarm system usually needs a way to introduce smoke or heat at a detector, keys for testing call points, and access poles for detectors at height. Addressable systems can also use a handheld programmer to check device addresses and outputs. The range here includes smoke pellets, a sampling test point and an addressable device programmer.

How is smoke detector test spray used?

Smoke detector test spray is an aerosol that puts a short burst of synthetic smoke into a detector's chamber to check that it goes into alarm. Hold the can at the distance the maker gives, spray briefly, then wait for the detector to respond and let the smoke clear before testing the next one. Use a spray approved for the detector type.

What is a smoke detector tester?

A smoke detector tester introduces test smoke, or a test signal, at a detector so an engineer can confirm it goes into alarm during routine servicing. Testers include aerosol test smoke, smoke pellets for aspirating systems and handheld programmers that show when an addressable detector has gone into alarm. The range here includes smoke pellets, a sampling test point and an addressable device programmer.

Why buy from West Midlands Electrics

  • Established 1975
  • Birmingham trade counter
  • UK-only supply

Written by the West Midlands Electrics technical team

Updated