Ajax Detectors
The Ajax detectors on this page are wireless fire detectors. The range here has EN54 FireProtect Jeweller smoke detectors such as the 119921.275.WH1, FireProtect 2 smoke and heat detectors in mains powered AC, replaceable battery RB and sealed battery SB versions, FireProtect 2 detectors that also sense carbon monoxide, FireProtect smoke and heat detectors, and FireProtect Plus detectors that add a carbon monoxide sensor to smoke and heat detection.
Ajax FireProtect 2 AC Mains Smart Fire & CO Detector, Heat/Smoke/CO 110-240V, 85dB, 107283.176
MultiSensorFast delivery Fri, 16 OctAjax FireProtect Plus Wireless Smoke, Heat & CO Detector, 85 dB, 38107.16.WH1
MultiSensorFast delivery Fri, 16 OctAjax FireProtect Wireless Smoke & Heat Detector, Black 38104.10.BL1
Dual DetectFast delivery Fri, 16 OctFireProtect Wireless Smoke & Heat Detector (White), Photoelectric, 85 dB, 38105.10.WH1
Smoke & HeatFast delivery Fri, 16 OctAjax FireProtect 2+ SB Wireless Smoke & Heat Detector, Sealed 10yr Battery, 85 dB
10yr BatteryFast delivery Fri, 16 Oct- 10yr BatteryFast delivery Fri, 16 Oct
- Dual SensorFast delivery Fri, 16 Oct
Ajax FireProtect 2 SB (Black) - Smoke & Heat Detector, Sealed 10-yr Battery, Jeweller Wireless
10yr BatteryFast delivery Fri, 16 OctAjax EN54 FireProtect Smoke Detector (Jeweller), Black - 119922.275.BL1
EN54Fast delivery Fri, 16 OctAjax EN54 FireProtect Smoke Detector with Built-in Sounder, Jeweller Wireless Black 119920.276.BL1
EN54Fast delivery Fri, 16 OctAjax FireProtect 2 SB Sealed-Battery Smoke & Heat Detector, White 106783.150.WH1
10‑YearFast delivery Fri, 16 Oct
Choosing Ajax Detectors
FireProtect Jeweller smoke detectors
The 119921.275.WH1, 119922.275.BL1 and 119920.276.BL1 are EN54-certified wireless addressable point smoke detectors for EN54-compliant systems. They use a dual-spectrum optical sensor (blue and infrared) and run on 2 × CR123A batteries, pre-installed. The 119921.275.WH1 is the smoke-only variant, and the 119920.276.BL1 adds an integrated sounder of up to about 85 dB at 1 m with selectable tones.
FireProtect 2
The FireProtect 2 AC 60832.175.WH1 combines a dual-spectrum smoke sensor with thermistor heat detection and a built-in siren. The AC versions are mains powered (110–240 V) with a non-replaceable backup cell, and the 107283.176 adds a chemical CO sensor. The FireProtect 2 RB runs on replaceable CR123A batteries. SB versions such as the FIREPROTECT2/SB(WHITE) and 106783.150.WH1 have sealed batteries rated for up to 10 years.
FireProtect and FireProtect Plus
The FireProtect 38104.10.BL1 and 38105.10.WH1 combine a photoelectric smoke chamber with a temperature sensor and a siren of about 85 dB. The FireProtect Plus 38106.16.BL1 and 38107.16.WH1 add a carbon monoxide sensor to smoke and heat detection, with a built-in 85 dB siren. The 38107.16.WH1 has CO alarm thresholds of 30, 50, 100 and 300 ppm and a battery life of up to 4 years.
| Model | Family | Sensing | Power |
|---|---|---|---|
| 119921.275.WH1 | EN54 FireProtect | Smoke | 2 × CR123A |
| 119920.276.BL1 | EN54 FireProtect | Smoke, with sounder | 2 × CR123A |
| 60832.175.WH1 | FireProtect 2 AC | Heat and smoke | Mains, backup cell |
| 107283.176 | FireProtect 2 AC | Heat, smoke and CO | Mains, backup battery |
| 106783.150.WH1 | FireProtect 2 SB | Smoke and heat | Sealed batteries |
| 38107.16.WH1 | FireProtect Plus | Smoke, heat and CO | CR2 and CR2032 |
Related categories
Detectors report to a hub: see Ajax alarm kits for hub-and-sensor kits and Ajax security systems for the wider system. Other wireless fire products are in wireless fire alarm systems, and smoke alarms from other makers in smoke alarms and detectors.
Frequently asked questions
Will an Ajax fire detector work without a hub?
Several will sound locally on their own. The FireProtect 2 AC 60832.175.WH1 is fully functional as a standalone local alarm, the FireProtect 2 RB FIREPROTECT2/RB(WHITE) can operate standalone with its built-in siren, and the FireProtect Plus 38107.16.WH1 can operate independently as a local siren. The 60832.175.WH1 needs an Ajax hub for monitored operation and full interconnect features.
What is the difference between FireProtect 2 RB and SB?
The batteries. The FireProtect 2 RB uses 2 × CR123A batteries, pre-installed and replaceable, with a typical service life of up to about 7 years, while SB versions such as the 106783.150.WH1 have sealed, non-replaceable batteries designed to power the detector for up to 10 years. The FireProtect 2 AC versions are mains powered instead.
Which Ajax detectors here also detect carbon monoxide?
They include the FireProtect 2 AC 107283.176 and the FireProtect Plus 38106.16.BL1 and 38107.16.WH1. The 107283.176 is mains powered and combines dual-spectrum optical smoke, Class A1R heat and chemical CO sensing, while the FireProtect Plus detectors combine smoke, heat and CO sensors with pre-installed batteries and a built-in 85 dB siren.
What is the EN54 FireProtect Jeweller range for?
Fire alarm systems that need EN54 certification. The 119922.275.BL1 is an EN54-certified wireless addressable point smoke detector for EN54-compliant systems, with Jeweller encrypted radio reaching up to 1,700 metres in open space, and 2 × CR123A batteries, pre-installed, with tool-free replacement.
Why buy from West Midlands Electrics
- Established 1975
- Birmingham trade counter
- UK-only supply
Updated