Access Control Systems
An access control system decides who can open a door and when, using a reader or keypad at the door, a controller that makes the decision and a lock that holds or releases the door. This range covers the parts: card, fob, face and fingerprint readers, keypads and code locks, single-door to networked controllers, maglocks and bolts, and exit buttons from Hikvision, CDVI, RGL, Paxton, TDSi and more.
125 kHz Proximity Clamshell Cards, 10 Pack, White ABS/PC, EM10C4 ACTPROX_HS-B
Durable Access£ 7 20RRP: £8.64Fast delivery Fri, 27 Nov2-Module Flush Mount Accessory, Stainless Steel Cover, DS-KD-ACF2/S
Dual-ModuleFast delivery Fri, 27 Nov7" Pro Face Recognition Terminal, Dual 2MP, 10k Faces, DS-K1T673DWX
10,000 FacesFast delivery Fri, 27 NovAB600ZL-DC Architectural Z & L Bracket for RGL ML600, Anodised Aluminium
Adjustable Fit£ 26 08RRP: £31.30Fast delivery Fri, 27 Nov- £ 1,721 59
Abloy EL580-50MM case solenoid bolt
£ 743 81Acre 6FL7820-8AE07-1L level lift interface
£ 4,074 09
Choosing Access Control Systems
Access control systems manage who can open a door: a card, fob, keypad or face recognition reader identifies the person, a door controller decides, and a magnetic lock holds the door until access is granted. Build the system from the door outwards: how people identify themselves, what decides, what locks, and how people leave.
Identify
Proximity and MIFARE card readers, keypads and code locks suit everyday doors. Biometric readers, such as the HID Global VL70LF-000-0000 facial recognition reader, remove the shared card or code. For outdoor positions, the Hikvision DS-K1T502DBWX-C terminal takes cards and PINs and is rated IP65 and IK09.
Decide
A standalone keypad controls one door on its own. Networked controllers manage several doors from software: the Hikvision DS-K2602T handles two doors over TCP/IP and RS-485, the DS-K2702X is expandable to 126 doors, and TDSi and Paxton Access supply enterprise and panel controllers.
Lock and release
RGL and Aperta maglocks hold the door by magnet and release on power loss, with Z and L brackets, such as the RGL AB600ZL-DC and CDVI 300-ZLAC, for inward-opening doors. Codelocks electronic and mechanical locks work without wiring. Exit buttons, DDA push plates and door release points let people leave.
| Part | Role | Examples |
|---|---|---|
| Reader or terminal | Identifies the user | Hikvision DS-KD-M, Hikvision DS-K1T344MBWX-QRE1 |
| Controller | Grants or refuses entry | Hikvision DS-K2602T, Paxton Access 010-403 |
| Lock | Holds the door | RGL ML600 maglock, Codelocks 0615 |
| Exit device | Releases from inside | CDVI RTE-AS, RGL EBLPP04, ESP EVEXITM |
Standards & compliance
The Abloy EL420 electronic lock meets EN 179 and EN 1125 for emergency and panic exit doors. The Paxton Access 900-600 and 900-610 PaxLock Pro are EN 179 certified for emergency exits, with the EN179 door kit required to comply.
Brands we stock in Access Control Systems
3E Security, Abloy, Acre, ACTpro, Adams Rite by ASSA ABLOY, Aiphone, Ajax, Alpro, Altronix, AMG Systems, Aritech, ASSA ABLOY, Axis Communications, Bell System, BPT, C-TEC, CAME, CDVI, CIE Group, Codelocks, Comelit PAC, CQR, Dahua Technology, Dantech Electronic Engineering, DMP, dormakaba, Elmdene, ESP, EZVIZ, Fermax, Genie, Haydon, HID Global, Hikvision, Honeywell Commercial Security, Hoyles, IDP, ievo, Kantech, Kentec Electronics, Kidde, LiftMaster, Nedap, Nortech, Optex, Opus Technologies, Paxton Access, RGL Electronics, Safety Technology International, STP, Takex, TDSi, Trimec, Urmet, Vanderbilt and Videx.
Hikvision supplies the most products.
Related categories
See keypads and readers and biometric and RFID systems for door hardware on its own. Access control is often paired with CCTV cameras, NVR recorders or Ajax alarm kits; setup advice is in our Help & Support guides.
Frequently asked questions
How does wireless access control work?
Wireless access control uses battery-powered locks or readers that talk by radio to a hub, and the hub connects to the main controller. This avoids running cable to the door, which suits finished, older or protected buildings. Check radio range and battery life before choosing. The range here includes a wireless lock hub and code locks that work without wiring.
Can access control be used at home?
Yes, access control can be used at home, usually as a keypad, fob reader or code lock on a front door, side gate or garage. A standalone unit suits a single door without a separate controller. For homes with several entrances, a networked system can manage them together and record who came and went.
How is an access control system installed?
An access control system is installed door by door: a reader outside, a lock on the door or frame, an exit button inside, and a controller and power supply nearby. Cabling then links the door devices back to the controller, unless wireless locks are used. Installers should check fire exit requirements, such as EN 179, and how the lock behaves when power fails.
What is an access control system?
An access control system is an electronic way of controlling who can open a door, gate or barrier, and when. Users present a card, fob, PIN, fingerprint or face, and the system unlocks the door when that credential is allowed. It replaces loose keys and can keep a record of entries. The range here includes readers, controllers, locks and exit buttons.
Why buy from West Midlands Electrics
- Established 1975
- Birmingham trade counter
- UK-only supply
Updated