View as

Knightsbridge Sockets (13A)

This page gathers Knightsbridge 13A sockets, which can be plain outlets or carry a second function in the plate. Plate finishes include white thermoset, anthracite, metal clad and decorative metal, and the socket types include switched and unswitched outlets, USB charging sockets, RCD sockets, key lockable and nightlight sockets, cooker switch combinations, floor, pop-up and under-cabinet units, IP66 outdoor sockets and smart Wi-Fi sockets.

Choosing Knightsbridge Sockets (13A)

Start with the job the outlet has to do, because many of these sockets build a second function into the plate.

Protection and control built in

The CU9RCD and PM9RCD put a 30mA Type A RCD into a 2G socket, and the CU9RCD is a passive type that resets itself after a power outage. Key lockable sockets such as the SFR9LOCKMW stop unsupervised use in hotel and apartment corridors. The SFR9NLMW has a photocell nightlight for landings, children's bedrooms or hotel hallways, which removes the need for a plug-in nightlight.

Remote, smart and speaker sockets

The CU9KW smart Wi-Fi socket works with Alexa and Google Assistant, shows power use in its app and is not suitable for EV charging. For the garden, the OP9R is an IP66 2G outdoor socket switched by a key fob at a range of up to 30 metres, with a 2990W maximum load. The CS9905BCW builds a 3W RMS Bluetooth speaker and a dual USB charger into a switched socket.

USB output

Charging power rises through the USB models. Dual USB-A sockets such as the FPR9901PCW share 2.1A and the SFR9124MW 2.4A, while dual USB A+C sockets such as the SFR9940MW share 4.0A. FASTCHARGE sockets such as the SFR9945MW give 45W over USB-C, enough for tablets and laptops, and quad USB sockets such as the SFR7USB4MW share 5.1A.

SocketExampleDetail
RCD socketCU9RCD30mA Type A, 2G DP
Nightlight socketSFR9NLMWPhotocell nightlight, 2G DP
Key lockableSFR9LOCKMW2G, double pole, 2 keys
Outdoor remoteOP9RIP66, 2990W max load
Pop-upSK9909BNIP54, dual USB A+C, 2m cable
Under cabinetSKR92G, dual USB A+C
Cooker combinationCU833345A DP switch with 13A socket
Metal cladMR90002G DP, back box supplied

Plate and box

Match the plate to the other accessories in the room: curved edge white plates such as the CU9000U, anthracite Part M such as the PM9001N, heavy duty metal clad such as the MR9000U, or screwless and flat plate metal. Check box depth before first fix; the SFR9000MW needs 25mm, while the CS9905BCW speaker socket needs a 35-47mm back box.

Related categories

Pair these outlets with Knightsbridge screwless switches and sockets, browse the Knightsbridge electrical range and Knightsbridge lights, compare makes in plug sockets and USB sockets, or step back to wiring accessories.

Frequently asked questions

What does an RCD socket add to a normal socket?

It adds residual current protection at the outlet itself. The CU9RCD and PM9RCD have a 30mA Type A RCD, which responds to AC residual current and pulsating DC. The CU9RCD trips in 40ms at its rated tripping current, suits equipment with electronic components such as IT devices, and resets itself after a power outage because it is a passive latching type.

Where would I fit a key lockable socket?

Fit one where unsupervised use has to be stopped, such as hotel and apartment corridors or other communal areas. The SFR9LOCKMW is a 2G double pole socket with a key lock mechanism, and it comes with 2 keys. Other lockable versions include brushed chrome, antique brass, smoked bronze and matt black plates, and the CU9LOCKN adds a neon indicator.

Can I switch an outdoor socket without going outside?

Yes, the OP9R is switched from a key fob. It is an IP66 and IK06 rated 2G outdoor socket with a 2990W maximum load, and the fob controls either socket at a range of up to 30 metres, suiting water features and garden lighting. The fob comes with its two CR2016 batteries; the OP9N and OP9RCD are IP66 outdoor sockets without the remote.

Why buy from West Midlands Electrics

  • Established 1975
  • Birmingham trade counter
  • UK-only supply

Written by the West Midlands Electrics technical team

Updated