Advanced MxPro 5 Addressable Fire Alarm Panel, 2-8 Loop, Nittan Evolution MX-5802N

Free Delivery
£ 4,304 22
(Incl. VAT) RRP: £5,165.06
Save £860.84

About this product

The Advanced MX-5802N is a 2-8 loop fire alarm control panel from the MxPro 5 series, for Nittan Evolution protocol devices. It suits larger and multi-area sites. It comes with 2 loop cards, expands to 8 loops, and has 8 onboard sounder circuits and 20 programmable zonal LEDs.

Key features

  • Starts at two loops and grows – 2 loop cards as standard, expandable to 8
  • Plenty of alarm outputs – 8 programmable 1 Amp sounder circuits
  • Clear to read and operate – white backlit 240 x 64 graphical LCD and keypad
  • Shows where the fire is – 20 programmable zonal LEDs with slide-in labels, plus 25 system LEDs
  • Networks with other MxPro 5 and MxPro 4 panels – peer-to-peer, standard network version
  • Easier commissioning – Auto-learn, loop detection and onboard scope

For installers

  • Power: 200-240v 47-63Hz AC mains, 1.4A max; charger 2 x 2.0A temperature compensated; 2 x 5A maximum total for loops, sounders and auxiliary supplies.
  • Mounting: steel IP30 enclosure in RAL7035, 750 x 450 x 190 mm (H x W x D), with a removable equipment chassis and plug-in connectors.
  • Cabling: 20mm knockouts, 30 top, 6 top rear, 2 bottom rear and 3 bottom; loops at 500mA max each; 2 x 24v 500mA auxiliary supplies.
  • Compatibility: Nittan Evolution protocol devices; devices per loop are protocol dependent.
  • Standards: EN54-2:1997+AC:1999+A1:2006 and EN54-4:1997+AC:1999+A1:2002+A2:2006.

Frequently asked questions

Which detectors does the MX-5802N work with?

Nittan Evolution protocol devices. Other protocols in the MxPro 5 range use different order codes, such as MX-5802A or MX-5802V.

How many loops come with it?

Two loop cards come as standard. For more loops, add one loop driver card per extra loop, up to 8.

Which loop card adds a loop?

The MXP-567 loop driver card, which is the Nittan version.

What batteries does it take?

From 24v 4Ah up to one 24V 45Ah battery inside, and a second 24V 45Ah battery in an optional external battery enclosure.

How many fire zones does it support?

Up to 400 across 8 loops, and up to 2000 when networked.

£ 4,304 22
RRP: £5,165.06 Save £860.84
Google Top Quality Store · Rated Exceptional
Ships from United Kingdom
28 days hassle free returns
Secure payment transactions
Price
£4,304.22 Incl. VAT £5,165.06
Add a WME Product Care Plan Includes warranty, replacement and repairs backed by WME
Why add a product care plan:
  • Full breakdown support
  • Full replacement if we can't repair your product within 10 days
  • All parts, labour and callouts included if necessary
  • Extended manufacturer warranty with faster turn arounds
  • Excludes accidental & cosmetic damages
By selecting one of these plans you agree to purchase WME Care Plan. Please read the Terms and Important information to ensure WME Care Plan is right for you. Compare prices of extended warranties for electrical goods at www.compareextendedwarranties.co.uk
WME Care
Technical Details
Specifications
Brand
Advanced
Model
MX-5802N
Manufacturer Part Number (MPN)
MX-5802N
Product
2-8 loop fire alarm control panel, MxPro 5 series
Protocol (this order code)
Nittan Evolution
Network version
Standard
Base technology
Dual flash-based processors with real-time clock, trace diagnostics, programmable languages and character sets
Display
White backlit 240 x 64 graphical LCD (5.5 inches x 2.5 inches)
LED indicators
22 red (1 Fire, 1 More Alarms, 20 zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault & System)
Number of fire zones
2000 when networked (400 max across 8 loops)
Number of loops
Dedicated 2-8 loop control panel; 2 loop cards as standard
Devices per loop
Protocol dependent
Loop current
500mA max per loop
On-board sounder circuits
8 x 1 Amp programmable
On-board relays
4 x 1 Amp 30v AC/DC programmable (10mA, 5v min); expandable to 8 using 2 x MXP-507
Auxiliary supply
2 x 24v 500mA
Programmable inputs
2 x on-board programmable input
Programmable key switch inputs
16 volt free digital inputs
Total output current
2 x 5A maximum for loop current + sounder outputs + auxiliary supply
Mains supply
200-240v 47-63Hz AC (+10%, -15% tolerance), 1.4A max
Charger current
2 x 2.0A temperature compensated
Ethernet port
10-Base-T, 100-Base-T, providing AdvancedLive connectivity
Serial ports
2 x on-board RS232 for PC, modem, IP or portable printer
USB interface
2 x USB B type for PC communication
Programming
On-board keypad or PC running Windows tools
Event log
2 x 5000 event & diagnostic + 500 fire
Enclosure / colour
Steel IP30 / RAL7035
Dimensions (H x W x D)
750 x 450 x 190 mm
Cable entry (20mm knockouts)
30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom
Battery capacity
24v 4Ah min; 24v 45Ah max; 1 x 24V 45Ah internal (max) and 1 x 24V 45Ah external (max) using optional battery enclosure
Operating temperature
-5°C to 40°C
Humidity (RH)
95% max
Metalwork options
Flushing bezel, battery box, utility enclosure, termination enclosure and rack mount
Extra loop card
MXP-567 loop driver card - Nittan, 1 per extra loop
Approvals
EN54-2:1997+AC:1999+A1:2006; EN54-4:1997+AC:1999+A1:2002+A2:2006
Dimensions
Dimensions
750 x 450 x 190 mm (H x W x D)

Specifications

Brand Advanced
Model MX-5802N
Manufacturer Part Number (MPN) MX-5802N
Product 2-8 loop fire alarm control panel, MxPro 5 series
Protocol (this order code) Nittan Evolution
Network version Standard
Base technology Dual flash-based processors with real-time clock, trace diagnostics, programmable languages and character sets
Display White backlit 240 x 64 graphical LCD (5.5 inches x 2.5 inches)
LED indicators 22 red (1 Fire, 1 More Alarms, 20 zonal programmable), 1 green (Power), 13 amber and 7 bi-colour (Fault & System)
Number of fire zones 2000 when networked (400 max across 8 loops)
Number of loops Dedicated 2-8 loop control panel; 2 loop cards as standard
Devices per loop Protocol dependent
Loop current 500mA max per loop
On-board sounder circuits 8 x 1 Amp programmable
On-board relays 4 x 1 Amp 30v AC/DC programmable (10mA, 5v min); expandable to 8 using 2 x MXP-507
Auxiliary supply 2 x 24v 500mA
Programmable inputs 2 x on-board programmable input
Programmable key switch inputs 16 volt free digital inputs
Total output current 2 x 5A maximum for loop current + sounder outputs + auxiliary supply
Mains supply 200-240v 47-63Hz AC (+10%, -15% tolerance), 1.4A max
Charger current 2 x 2.0A temperature compensated
Ethernet port 10-Base-T, 100-Base-T, providing AdvancedLive connectivity
Serial ports 2 x on-board RS232 for PC, modem, IP or portable printer
USB interface 2 x USB B type for PC communication
Programming On-board keypad or PC running Windows tools
Event log 2 x 5000 event & diagnostic + 500 fire
Enclosure / colour Steel IP30 / RAL7035
Dimensions (H x W x D) 750 x 450 x 190 mm
Cable entry (20mm knockouts) 30 x top, 6 x top rear, 2 x bottom rear and 3 x bottom
Battery capacity 24v 4Ah min; 24v 45Ah max; 1 x 24V 45Ah internal (max) and 1 x 24V 45Ah external (max) using optional battery enclosure
Operating temperature -5°C to 40°C
Humidity (RH) 95% max
Metalwork options Flushing bezel, battery box, utility enclosure, termination enclosure and rack mount
Extra loop card MXP-567 loop driver card - Nittan, 1 per extra loop
Approvals EN54-2:1997+AC:1999+A1:2006; EN54-4:1997+AC:1999+A1:2002+A2:2006

Dimensions

Dimensions 750 x 450 x 190 mm (H x W x D)

Advanced MX-5802N 2-8 loop fire alarm panel, front view

Advanced MxPro 5 Addressable Fire Alarm Panel, 2-8 Loop, Nittan Evolution MX-5802N

Overview

A multi-loop fire alarm panel runs several loops of detectors, call points and sounders from one cabinet. Advanced builds this panel for larger sites, and this order code is the Nittan Evolution version on a standard network.

It is one of the commercial fire alarm panels in the MxPro 5 series, and it can be networked with other MxPro 5 or MxPro 4 panels.

How it works

  • Addressable loops: each device on a loop has its own address, so the panel can name the exact device in alarm. Every device on every loop must share the panel's protocol, which here is Nittan Evolution.
  • Cause and effect: programmable rules link inputs to outputs, and enhanced Trace Diagnostics help with fault finding.
  • Dual processors: dual flash-based processors with a real-time clock run the panel and keep two event logs of 5000 event and diagnostic entries plus 500 fire entries.

Where to use it

It suits buildings that need more than one loop, from small sites to large complex multi-area systems. The steel IP30 enclosure belongs indoors in a dry plant room or entrance, between -5°C and 40°C and up to 95% humidity.

What the figures mean in practice

  • 400 zones across 8 loops: a zone is the area responders are sent to; a fully built panel covers 400, and 2000 across a network.
  • 2 x 5A output: loops, sounder circuits and the two 24v auxiliary supplies share this budget, so total the loads when planning.
  • Up to 45Ah batteries: one battery fits inside and a second in the optional battery enclosure, which helps on sites that need long standby times.

Installing it

The equipment chassis lifts out and uses plug-in connectors, which makes fixing the cabinet and terminating cables simpler. Plan cable routes before fixing, as entries are on the top, the rear and the bottom of the cabinet.

During commissioning, Auto-learn and loop detection find the devices, and the onboard scope helps find loop faults. The eight 1 Amp sounder circuits drive conventional sounders and bells wired to them.

Planning your system

  • Extra loops: two loop cards come fitted; add one MXP-567 Nittan loop driver card per extra loop, up to 8.
  • Relays: four programmable 1 Amp relays are on board, and two MXP-507 relay cards take the relay count to 8.
  • Power reserve: choose standby batteries up to 45Ah from the system's standby and alarm load.
  • Expansion: the integral P-Bus accepts option cards, and other panel modules and interfaces extend what the system can do.

Standards and ratings explained

EN54-2 covers fire alarm control and indicating equipment, and EN54-4 covers its power supply equipment; this panel is approved to both. IP30 means the enclosure keeps out fingers and tools but gives no protection against water.

Advanced MX-5802N 2-8 loop fire alarm panel, front view
Advanced

Advanced MxPro 5 Addressable Fire Alarm Panel, 2-8 Loop, Nittan Evolution MX-5802N

£4,304.22 £5,165.06

The Advanced MX-5802N is a 2-8 loop fire alarm control panel from the MxPro 5 series, for Nittan Evolution protocol devices. It suits larger and multi-area sites. It comes with 2 loop cards, expands to 8 loops, and has 8 onboard sounder circuits and 20 programmable zonal LEDs.

Key features

For installers

Frequently asked questions

Which detectors does the MX-5802N work with?

Nittan Evolution protocol devices. Other protocols in the MxPro 5 range use different order codes, such as MX-5802A or MX-5802V.

How many loops come with it?

Two loop cards come as standard. For more loops, add one loop driver card per extra loop, up to 8.

Which loop card adds a loop?

The MXP-567 loop driver card, which is the Nittan version.

What batteries does it take?

From 24v 4Ah up to one 24V 45Ah battery inside, and a second 24V 45Ah battery in an optional external battery enclosure.

How many fire zones does it support?

Up to 400 across 8 loops, and up to 2000 when networked.