Advanced MxPro 5 BMS Interface, Boxed, Fault Tolerant Network MXP-510-BX/FT

Free Delivery
£ 1,165 96
(Incl. VAT) RRP: £1,399.15
Save £233.19

About this product

The Advanced MXP-510-BX/FT is a BMS interface for linking building management systems and graphical control PCs to MxPro 5 fire control panels. It suits sites that want fire events on a graphics PC. This boxed version is for a fault tolerant network, and connects through an isolated RS232 interface.

Key features

  • Brings fire events to a PC – BMS systems and graphical control PCs integrate with MxPro 5 panels and remote terminals
  • Built for fault tolerant networks – the boxed fault tolerant network version of the interface
  • Sits on the network itself – an integral part of the Ad-Net network, handling network traffic and event prioritisation
  • More than one control point – multiple interfaces can connect for sites with several graphical PCs
  • Set up to suit the site – sector based programming, with cause and effects rules on each interface
  • Ready to fit – boxed, in an enclosure of 218 x 300 x 45 mm

For installers

  • Power: 18-28V DC supply input, drawing 86mA at 24V DC on this fault tolerant version.
  • Mounting: enclosure 218 x 300 x 45 mm (H x W x D), weighing 2Kg.
  • Cabling: isolated RS232 to the BMS or PC, plus a monitored volt free clean contact fault input.
  • Compatibility: can be used with any Ad-NeT or Ad-NeT+ network series control panels. Third party graphics systems need a protocol translator.

Frequently asked questions

What does a BMS interface do on a fire alarm?

It lets a BMS or a graphical control PC work with the fire panels. BMS systems and graphical control PCs are integrated with MxPro 5 panels and remote terminals through it.

Is this the fault tolerant version?

Yes. MXP-510-BX/FT is the fault tolerant network version in an enclosure. MXP-510-BX is the standard network boxed version.

Can it talk to third party graphics software?

Yes, with a protocol translator. It provides connection to various 3rd party graphics systems that way.

Can a site have more than one?

Yes. Multiple interfaces can be connected to the network where control is needed from several graphical PCs.

How is it configured?

Through PC-NET-003. Each interface is then individually programmable with cause and effects rules.

£ 1,165 96
RRP: £1,399.15 Save £233.19
Google Top Quality Store · Rated Exceptional
Ships from United Kingdom
28 days hassle free returns
Secure payment transactions
Price
£1,165.96 Incl. VAT £1,399.15
Add a WME Product Care Plan Includes warranty, replacement and repairs backed by WME
Why add a product care plan:
  • Full breakdown support
  • Full replacement if we can't repair your product within 10 days
  • All parts, labour and callouts included if necessary
  • Extended manufacturer warranty with faster turn arounds
  • Excludes accidental & cosmetic damages
By selecting one of these plans you agree to purchase WME Care Plan. Please read the Terms and Important information to ensure WME Care Plan is right for you. Compare prices of extended warranties for electrical goods at www.compareextendedwarranties.co.uk
WME Care
Technical Details
Specifications
Brand
Advanced
Model
MXP-510-BX/FT
Manufacturer Part Number (MPN)
MXP-510-BX/FT
Also listed as
Mxp-510-BX/FT
Product type
BMS/Graphics Interface, boxed
Network type
Fault tolerant network
Supply voltage input
18-28V DC
Supply current
86mA at 24V DC
Operating temperature
-5°C to 50°C
Relative humidity
95% non-condensing (maximum)
PCB dimensions (H x W x D)
88 x 242 x 18 mm
Weight
75 grams
Enclosure dimensions (H x W x D)
218 x 300 x 45 mm
Enclosure weight
2Kg
Indications
On-board LED indicators for heartbeat, network Rx/Tx and RS232 Rx/Tx
Serial interface
Isolated RS232 interface for BMS/PC
Fault input
Monitored volt free clean contact
Configuration
PC-NET-003
Compatibility
Any Ad-NeT or Ad-NeT+ network series control panels
Dimensions
Dimensions
Enclosure 218 x 300 x 45 mm (H x W x D)

Specifications

Brand Advanced
Model MXP-510-BX/FT
Manufacturer Part Number (MPN) MXP-510-BX/FT
Also listed as Mxp-510-BX/FT
Product type BMS/Graphics Interface, boxed
Network type Fault tolerant network
Supply voltage input 18-28V DC
Supply current 86mA at 24V DC
Operating temperature -5°C to 50°C
Relative humidity 95% non-condensing (maximum)
PCB dimensions (H x W x D) 88 x 242 x 18 mm
Weight 75 grams
Enclosure dimensions (H x W x D) 218 x 300 x 45 mm
Enclosure weight 2Kg
Indications On-board LED indicators for heartbeat, network Rx/Tx and RS232 Rx/Tx
Serial interface Isolated RS232 interface for BMS/PC
Fault input Monitored volt free clean contact
Configuration PC-NET-003
Compatibility Any Ad-NeT or Ad-NeT+ network series control panels

Dimensions

Dimensions Enclosure 218 x 300 x 45 mm (H x W x D)

Advanced MXP-510-BX/FT BMS graphics interface, card and enclosure view

Advanced MxPro 5 BMS Interface, Boxed, Fault Tolerant Network MXP-510-BX/FT

Overview

A large fire alarm usually has a panel in one place and people who need to see it in another. A graphics PC shows events on a floor plan, and a building management system, or BMS, can pass them on to the rest of the building's controls.

This Advanced unit is the link between those systems and the fire panels, in the version for a fault tolerant network. It suits facilities teams, integrators and fire engineers working on networked sites.

How it works

  • On the network: The interface joins the Ad-Net network as a device in its own right, so it handles the traffic and works out which events take priority.
  • Out to the PC: A simple RS232 serial link carries that information to the PC or BMS. RS232 is a long-established point-to-point serial connection.
  • Programmed per sector: Sector based programming lets each interface look after its own part of the site. Cause and effect rules decide what happens when a given event occurs.

Where to use it

It fits sites that manage fire events from a control room or several control points, because more than one interface can sit on the same network. It also fits sites adding a third party graphics package, with a protocol translator between the two.

Installing it

  • Supply: As a rule, check the supply has spare capacity for the added load, and that the power source is suitable for fire system use.
  • Fault monitoring: The fault input takes a clean contact, so whatever signals the fault must be volt free.
  • Diagnosis: The on-board LED indicators for heartbeat, network and RS232 traffic give a quick first check when a link appears to be down.

Planning your system

A standard network needs the MXP-510-BX instead, so check your panels' network type before ordering. Plan for PC-NET-003 at commissioning, as that is the configuration route.

Browse the wider Advanced range for the panels and cards around it.

Advanced MXP-510-BX/FT BMS graphics interface, card and enclosure view
Advanced

Advanced MxPro 5 BMS Interface, Boxed, Fault Tolerant Network MXP-510-BX/FT

£1,165.96 £1,399.15

The Advanced MXP-510-BX/FT is a BMS interface for linking building management systems and graphical control PCs to MxPro 5 fire control panels. It suits sites that want fire events on a graphics PC. This boxed version is for a fault tolerant network, and connects through an isolated RS232 interface.

Key features

For installers

Frequently asked questions

What does a BMS interface do on a fire alarm?

It lets a BMS or a graphical control PC work with the fire panels. BMS systems and graphical control PCs are integrated with MxPro 5 panels and remote terminals through it.

Is this the fault tolerant version?

Yes. MXP-510-BX/FT is the fault tolerant network version in an enclosure. MXP-510-BX is the standard network boxed version.

Can it talk to third party graphics software?

Yes, with a protocol translator. It provides connection to various 3rd party graphics systems that way.

Can a site have more than one?

Yes. Multiple interfaces can be connected to the network where control is needed from several graphical PCs.

How is it configured?

Through PC-NET-003. Each interface is then individually programmable with cause and effects rules.

View product