CDVI 300kg Maglock, Double Surface, 2 x 300kg, Monitored, Fail Safe C3S12
About this product
The CDVI C3S12 is a double 300kg maglock for internal double doors, with two magnets in one surface mounted body. It is fail safe, so it releases when power is removed, and it runs on 12-24Vdc. It suits access control installers who need live status monitoring on a pair of doors.
Key features
- One lock for a pair of doors – 2 x 300kg holding force
- Simple to fix – surface mounting
- Reports back to your system – live status monitoring, with 2 relays and NO/NC contacts
- Easy on the power supply – low consumption, 590mA @ 12Vdc
- Resists rough treatment – IK10 (impact rating), aluminium body
- Choice of supply – 12-24Vdc power input
For installers
- Power: 12-24Vdc, consumption 590mA @ 12Vdc or 285mA @ 24Vdc. Fail safe.
- Mounting: surface, for internal use only. Maglock 500 x 43 x 26 mm, armature plate 185 x 38 x 11 mm, weight 3.55kg.
- Compatibility: fully compatible with CDVI brackets, housings and accessories, including the LD3 L-bracket and Z3Z4Z5 Z-bracket.
- Standards: IP42, IK10, 100kg pre-load (FR regulation NFS 61-937). Temperature -20°C to 60°C.
In the box
- Armature plate
- Fixing kit
- Full fitting instructions
Frequently asked questions
Is this a 600kg maglock?
No. It is rated 2 x 300kg, which means two 300kg magnets in one body, one for each door leaf.
Does it stay locked in a power cut?
Only while its own power supply stays on, because it is fail safe. As a rule, it stays held through a mains cut only if a battery-backed supply is powering it, and on an escape route it must still release, usually through a fire alarm link and a release device. Check this with whoever holds the building's fire strategy.
Can it be used outdoors?
No. It is for internal use only, and it is rated IP42.
How much current does it draw?
590mA @ 12Vdc or 285mA @ 24Vdc.
Can it report door status?
Yes. It has live status monitoring, with 2 relays and NO/NC contacts.
Are brackets needed?
It depends on your doors and frame. The LD3 L-bracket and the Z3Z4Z5 Z-bracket are its accessories, so choose by the layout of your doors and frame.
-
Download
- C3S12 datasheet
Specifications
Dimensions
Specifications
| Brand | CDVI |
|---|---|
| Model | C3S12 |
| Manufacturer Part Number (MPN) | C3S12 |
| Product type | Entry level double surface 300kg magnetic lock, monitored |
| Mounting | Surface |
| Lock mode | Fail Safe |
| Holding force | 2 x 300kg |
| Monitoring | Live status monitoring |
| Relays | 2 |
| Contacts | NO/NC |
| Material | Aluminium |
| Weight | 3.55kg |
| Maglock dimensions | 500 x 43 x 26 mm |
| Armature plate dimensions | 185 x 38 x 11 mm |
| Power input | 12-24Vdc |
| Consumption | 590mA @ 12Vdc, 285mA @ 24Vdc |
| Use | For internal use only |
| Ingress protection | IP42 |
| Impact protection | IK10 |
| Temperature range | -20°C to 60°C |
| Pre-load | 100kg pre-load (FR regulation NFS 61-937) |
| Accessory, L-bracket | LD3 L-bracket for double surface mount 300kg electro-magnetic locks |
| Accessory, Z-bracket | Z3Z4Z5 Z-bracket for 300kg, 400kg and 500kg electro-magnetic locks |
Dimensions
| Dimensions | Maglock 500 x 43 x 26 mm, armature plate 185 x 38 x 11 mm |
|---|
CDVI 300kg Maglock, Double Surface, 2 x 300kg, Monitored, Fail Safe C3S12