CDVI Fail Safe Solenoid Lock, Monitored, Flush Mount, 12-24Vdc DX200i
About this product
The CDVI DX200i is a fail safe solenoid lock for doors on access control systems, running on 12-24Vdc. It mounts flush and has a rotating saw-proof roller bolt. It monitors door and lock status, so it suits installers who need the state of the door reported back.
Key features
- Reports the door state – door and lock status monitoring
- Hard to attack – rotating saw-proof roller bolt
- Sets its own voltage – automatic voltage selection 12/24Vdc
- Choose the unlock time – adjustable 3 to 30 sec relock timer
- Copes when a door sits out of line – retry circuit
- Built for repeated use – 100,000 cycles tested, stainless steel faceplate
- Tough face – IK10 impact rating
For installers
- Power: 12-24Vdc (free voltage). In-rush 1.3A @ 12Vdc or 0.8A @ 24Vdc. Fail safe.
- Mounting: flush, mortice mount, vertical mounting recommended. Weight 0.44kg.
- Cabling: 1 x NO/NC relay. Contacts for push button, door position and bolt position.
- Compatibility: the KDX200 stainless steel surface housing is the accessory for this lock.
- Standards: IP42, IK10, -10°C to 60°C.
Frequently asked questions
Does it stay locked in a power cut?
No, not unless its supply keeps running, because it is fail safe. It stays locked through a mains cut only on a battery-backed supply, and on an escape route it must still release, usually through a fire alarm link and a release device. Check this with whoever holds the building's fire strategy.
What does monitored mean on this lock?
It means the lock signals both door position and bolt position through its contacts, so a controller can see the door's full status.
Can it be surface mounted?
Yes, with a housing. The lock itself is mortice mount, and the KDX200 is its stainless steel surface housing.
How long does it stay unlocked?
That is set by the relock timer, which adjusts from 3 to 30 sec.
Which way up should it be fitted?
Vertical mounting is what CDVI recommends.
Can it be used outside?
It is rated IP42 and -10°C to 60°C, so do not plan on it for an exposed door.
-
Download
- DX200i datasheet
Specifications
Specifications
| Brand | CDVI |
|---|---|
| Model | DX200i |
| Manufacturer Part Number (MPN) | DX200i |
| Also listed as | DX200I |
| Product type | Fail safe solenoid bolt, monitored |
| Lock mode | Fail safe |
| Power input | 12-24Vdc (free voltage) |
| In-rush consumption | 1.3A @ 12Vdc, 0.8A @ 24Vdc |
| Material | Stainless steel |
| Mounting | Flush |
| Cycles tested | 100,000 |
| Relays | 1 x NO/NC |
| Contacts | Push button, door position, bolt position |
| Relock delay | From 3 to 30 sec |
| Weight | 0.44kg |
| Ingress protection | IP42 |
| Impact protection | IK10 |
| Temperature range | -10°C to 60°C |