Comelit Addressable Manual Call Point with Isolator, Red 41PAM000

£ 32 65
(Incl. VAT) RRP: £39.18
Save £6.53

About this product

The Comelit 41PAM000 is an addressable manual call point for raising a fire alarm by hand on an addressable fire detection system. It suits installers fitting or extending a system on a wall. It has a built-in isolator, a resettable plastic element and a red ABS case.

Key features

  • Raises the alarm with one press – sends an alarm signal to the control panel when the indicated point is pressed
  • Nothing to replace after a press – a resettable special plastic key element, supplied
  • Helps contain a wiring fault – a built-in isolator, a part that cuts off a short circuit
  • Shows what state it is in – an LED signals the alarm or test status
  • Easy to pick out on a wall – a red ABS container
  • Compact on the wall – 90 mm wide, 90 mm high and 56 mm deep

For installers

  • Power: operating voltage 15 to 32, 27 VDC nominal.
  • Mounting: wall mounting, 90 mm wide, 90 mm high and 56 mm deep.
  • Compatibility: addressable manual call point. Check the panel and protocol with your panel maker.
  • Standards: approved to EN 54-11 and EN 54-17.

Frequently asked questions

Does the element have to be replaced after use?

No. The fragile element type is resettable, and it is a special plastic key element that comes supplied.

Does it have a built-in isolator?

Yes. The isolator is built in.

Which fire panels does it work with?

It is an addressable device, so confirm compatibility and the protocol with your panel maker before ordering.

What does the LED show?

It signals the alarm or test status.

What voltage does it run on?

15 to 32, with 27 VDC nominal.

Is it suitable for outdoor use?

Check the IP rating you need against the unit's documentation before fitting it outdoors. It is made for wall mounting, so do not assume a weatherproof rating.

£ 32 65
RRP: £39.18 Save £6.53
Google Top Quality Store · Rated Exceptional
Ships from United Kingdom
28 days hassle free returns
Secure payment transactions
Price
£32.65 Incl. VAT £39.18
Add a WME Product Care Plan Includes warranty, replacement and repairs backed by WME
Why add a product care plan:
  • Full breakdown support
  • Full replacement if we can't repair your product within 10 days
  • All parts, labour and callouts included if necessary
  • Extended manufacturer warranty with faster turn arounds
  • Excludes accidental & cosmetic damages
By selecting one of these plans you agree to purchase WME Care Plan. Please read the Terms and Important information to ensure WME Care Plan is right for you. Compare prices of extended warranties for electrical goods at www.compareextendedwarranties.co.uk
WME Care
Technical Details
Specifications
Brand
Comelit
Model
41PAM000
Manufacturer Part Number (MPN)
41PAM000
Product type
Addressable manual call point
Range
Fire detection
Type of detection point
Manual alarm button
Fragile element type
Resettable
Isolator
Yes
Mounting
Wall mounting
Finishing material
ABS
Colour
Red
Width
90 mm
Height
90 mm
Depth
56 mm
Operating humidity
0 to 96 % (RH max @40°C)
Operating temperature
-10 to 60 °C
Operating voltage
15 to 32, 27 VDC nominal
Consumption during communication
160uA@27VDC
EN regulations
EN54-11, EN54-17
Weight
175 g
Dimensions
Dimensions
90 mm wide x 90 mm high x 56 mm deep

Specifications

Brand Comelit
Model 41PAM000
Manufacturer Part Number (MPN) 41PAM000
Product type Addressable manual call point
Range Fire detection
Type of detection point Manual alarm button
Fragile element type Resettable
Isolator Yes
Mounting Wall mounting
Finishing material ABS
Colour Red
Width 90 mm
Height 90 mm
Depth 56 mm
Operating humidity 0 to 96 % (RH max @40°C)
Operating temperature -10 to 60 °C
Operating voltage 15 to 32, 27 VDC nominal
Consumption during communication 160uA@27VDC
EN regulations EN54-11, EN54-17
Weight 175 g

Dimensions

Dimensions 90 mm wide x 90 mm high x 56 mm deep

Comelit 41PAM000 addressable manual call point, front view

Comelit Addressable Manual Call Point with Isolator, Red 41PAM000

What this call point does

A manual call point lets anyone who sees a fire start the alarm by hand, without waiting for a detector to react.

This one belongs on an addressable system, where the panel knows each device individually. It suits installers and maintenance teams working on those systems.

How it works

  • Pressing it: the user presses the indicated point on the front, and the unit signals the control panel.
  • Putting it back: the element is plastic and resettable, so there is no glass to clear up. The key element comes supplied.
  • The isolator: As a rule, isolators split an addressable loop into sections, so a short circuit takes out only part of the wiring and not the whole loop.

Where to use it

It is made for wall mounting. Call points usually sit on routes out of a building and beside final exits, and the system design sets their exact positions.

Treat it as an indoor device unless your panel maker or designer confirms otherwise.

What the figures mean in practice

  • Standby use: the figure here is consumption during communication, so use your panel maker's loop calculator for the full load.
  • Temperature and humidity: compare the operating limits with the space, and do not assume an outdoor or weatherproof rating.

Planning your system

The job also needs an addressable control panel that accepts this device. A protocol is the digital language a panel and its devices must share, so settle that with the panel's maker first.

As a rule, test every call point at the intervals your system design and maintenance plan set out.

Standards explained

  • EN 54-11: the European standard for manual call points.
  • EN 54-17: the European standard for short-circuit isolators, which is why it sits alongside the call point standard here.
Comelit 41PAM000 addressable manual call point, front view
Comelit PAC

Comelit Addressable Manual Call Point with Isolator, Red 41PAM000

£32.65 £39.18

The Comelit 41PAM000 is an addressable manual call point for raising a fire alarm by hand on an addressable fire detection system. It suits installers fitting or extending a system on a wall. It has a built-in isolator, a resettable plastic element and a red ABS case.

Key features

For installers

Frequently asked questions

Does the element have to be replaced after use?

No. The fragile element type is resettable, and it is a special plastic key element that comes supplied.

Does it have a built-in isolator?

Yes. The isolator is built in.

Which fire panels does it work with?

It is an addressable device, so confirm compatibility and the protocol with your panel maker before ordering.

What does the LED show?

It signals the alarm or test status.

What voltage does it run on?

15 to 32, with 27 VDC nominal.

Is it suitable for outdoor use?

Check the IP rating you need against the unit's documentation before fitting it outdoors. It is made for wall mounting, so do not assume a weatherproof rating.