CQR Electronic Panic Button, Key Resettable, Stainless Steel, Surface or Flush EPA/STD/SS

£ 40 50
(Incl. VAT) RRP: £48.60
Save £8.10

About this product

The CQR EPA/STD/SS is an electronic panic button for wired alarm systems, in a stainless steel housing. It suits shops, offices, schools and healthcare settings where staff may need to call for help in an emergency. It fits on the surface or flush, latches when pressed, and a key resets it.

Key features

  • Fits the room – surface or flush fitting
  • Stays on until dealt with – latching
  • Shows it has been used – LED indicator to show activation
  • Only a key clears it – key resettable, with spare keys as an option
  • Harder to interfere with – cover tamper with spring tamper protection
  • Plenty of connections – 8 terminals with change over relay

For installers

  • Power: 12 Vdc nominal.
  • Mounting: surface / flush.
  • Cabling: terminal connection, 8 terminals with change over relay. Check the panel's documentation for the zone wiring it expects.
  • Standards: EN50131-1, EN50130-5, environmental class II. Tamper protection RFMS spring.

Frequently asked questions

Is it surface or flush mounted?

Either. It is made for surface or flush fitting.

How is it reset?

With a key. It is key resettable, and spare keys can be ordered.

Does it stay active after being pressed?

Yes. It is latching, and the LED indicator shows that it has been activated.

What voltage does it need?

12 Vdc.

Does it have a confirmed output?

No. It has no confirmed output and is not a timed device.

£ 40 50
RRP: £48.60 Save £8.10
Google Top Quality Store · Rated Exceptional
Ships from United Kingdom
28 days hassle free returns
Secure payment transactions
Price
£40.50 Incl. VAT £48.60
Add a WME Product Care Plan Includes warranty, replacement and repairs backed by WME
Why add a product care plan:
  • Full breakdown support
  • Full replacement if we can't repair your product within 10 days
  • All parts, labour and callouts included if necessary
  • Extended manufacturer warranty with faster turn arounds
  • Excludes accidental & cosmetic damages
By selecting one of these plans you agree to purchase WME Care Plan. Please read the Terms and Important information to ensure WME Care Plan is right for you. Compare prices of extended warranties for electrical goods at www.compareextendedwarranties.co.uk
WME Care
Technical Details
Specifications
Brand
CQR
Model
EPA/STD/SS
Manufacturer Part Number (MPN)
EPA/STD/SS
Product type
Electronic Panic Button
Environmental class
II
Standards
EN50131-1, EN50130-5
Tamper protection
RFMS Spring
Connection type
Terminals
Colour
Stainless Steel
Material
Stainless Steel
Voltage range
12 Vdc
Nominal voltage
12 Vdc
Visual indication
Yes
Reset method
Key
Confirmed output
No
Operation mode
Push
Timed
No
Mounting method
Surface / Flush
No. terminals
8

Specifications

Brand CQR
Model EPA/STD/SS
Manufacturer Part Number (MPN) EPA/STD/SS
Product type Electronic Panic Button
Environmental class II
Standards EN50131-1, EN50130-5
Tamper protection RFMS Spring
Connection type Terminals
Colour Stainless Steel
Material Stainless Steel
Voltage range 12 Vdc
Nominal voltage 12 Vdc
Visual indication Yes
Reset method Key
Confirmed output No
Operation mode Push
Timed No
Mounting method Surface / Flush
No. terminals 8

CQR EPA/STD/SS electronic panic button, front view

CQR Electronic Panic Button, Key Resettable, Stainless Steel, Surface or Flush EPA/STD/SS

Overview

A panic button gives people a fixed point to raise an alarm without reaching the keypad. In a reception, a treatment room or behind a counter, that can matter more than any other part of the system.

This one has a plain stainless steel plate. It is one of many options in the panic and personal alarms range, so compare styles if the room calls for something else.

How it works

  • Pressing it: The push action operates the alarm output, and the latching action holds that state.
  • Seeing it: The LED shows whoever arrives next that this is the button that was used.
  • Clearing it: The key returns it to normal, so a reset stays with whoever holds the key.

Where to use it

Environmental class II is generally taken to mean indoor use in a protected space. Fit it where staff can reach it easily and calmly, and where it is not knocked in everyday use.

What happens after the press, including any monitoring or police response, depends on how the alarm system is set up and not on this button alone. As a rule, agree that with whoever looks after the system.

Installing it

  • Surface or flush: Choose the fitting method before cabling, because it decides how the cable reaches the back of the plate.
  • Connections: Connect through the terminals, using the change over relay to suit the zone. Connect the tamper as the panel requires.
  • Testing: In most installations each button is pressed and reset during commissioning, with the receiving end warned first.

Planning your system

The button needs an alarm panel input to work with. The guide to burglar alarms explains how the parts fit together, and the wider burglar and intruder alarms range covers the rest of the job.

Decide who keeps the key and where the spare goes. A button nobody can reset is a problem on the day it is used.

Standards and ratings explained

EN50131-1 is the general requirement of the European intruder alarm standard, and EN50130-5 deals with environmental testing. The article on the British standard for intruder alarms explains the grades.

RFMS stands for removal from mounting surface. It means an attempt to take the unit off the wall can be signalled, along with the cover tamper.

CQR EPA/STD/SS electronic panic button, front view
CQR

CQR Electronic Panic Button, Key Resettable, Stainless Steel, Surface or Flush EPA/STD/SS

£40.50 £48.60

The CQR EPA/STD/SS is an electronic panic button for wired alarm systems, in a stainless steel housing. It suits shops, offices, schools and healthcare settings where staff may need to call for help in an emergency. It fits on the surface or flush, latches when pressed, and a key resets it.

Key features

For installers

Frequently asked questions

Is it surface or flush mounted?

Either. It is made for surface or flush fitting.

How is it reset?

With a key. It is key resettable, and spare keys can be ordered.

Does it stay active after being pressed?

Yes. It is latching, and the LED indicator shows that it has been activated.

What voltage does it need?

12 Vdc.

Does it have a confirmed output?

No. It has no confirmed output and is not a timed device.