Fike 205-0001 smoke alarm, White

£ 64 86
(Incl. VAT)

About this product

Fike 205-0001 is a smoke alarm.

The Multipoint ASD detectors have set new standards in detector technology. The Addressable ASD detector is used on the Duonet and Quadnet systems. The detectors can be matched to the environment in which they are installed and changed any time during the lifetime of the installation.

The mode of detection required can be changed simply by configuring the DIL switch in the detector electronics module (configurable via commissioning software on addressable systems). All modes are compliant with European detector type specifications. The Addressable ASD detector offers multiple choices for detection, set to a single mode or a combination, for a choice of up to 15 different settings.

Programmable via a PC or at the panel (Quadnet and Duonet only) and also has an in-built loop isolator as well as I/O for local control and switching. The Multipoint ASD detectors have the unique benefit of an optional full specification integral sounder, where 90dBA output can be achieved. The Addressable ASD detector has 7 different sound patterns and 3 volume settings.

All Multipoint ASD detectors have the option of an integral combined strobe. Modes of Detection

Smoke 1: Used where ionisation detectors are normally fitted, especially when there are high ceilings or a risk of free burning fires (chemical stores etc.) or fires that need to be detected extremely quickly. Smoke 2: Used where optical detectors are normally fitted, when there is a risk of a smouldering fire and for escape routes. Smoke 3: Designed for use in areas that are prone to nuisance alarms.

The reduced sensitivity linked with a time delay feature, means that a higher concentration of smoke needs to be present for a constant time period, before a fire decision is made. For example, this setting is ideal for hotel bedrooms with en-suite shower rooms. Heat 2 (Standard Fixed Temperature – 58ºC approx.): Used where a standard fixed temperature heat detector would normally be fitted, suitable for kitchens etc.

Heat 3 (High Fixed Temperature – 90ºC approx.): Used where a high fixed temperature heat detector would normally be fitted. Suitable for commercial kitchens, boiler rooms etc.To ensure the detection capabilities of the detectors are never compromised they self-calibrate every 6 hours. They also continuously monitor for dust contamination until, depending on the environment, it reaches a point where the chamber becomes saturated.

Before this can develop into a false alarm situation, the panel will indicate that the device in question requires attention.

Key features

  • Fast short circuit isolator in every device
  • 15 combinations of smoke & heat detection modes
  • Multi stage alarms - pre alarm feature
  • 7 sound patterns - plus off, 3 different volume settings - if using Sita
  • Multipoint with integral sounder
  • Auxiliary digital inputs and outputs are available at any Addressable
  • Multipoint device
  • Automatic continuous self-calibration
  • Fast short circuit isolator in every device
£ 64 86
Google Top Quality Store · Rated Exceptional
Ships from United Kingdom
28 days hassle free returns
Secure payment transactions
Price
£64.86 Incl. VAT
Add a WME Product Care Plan Includes warranty, replacement and repairs backed by WME
Why add a product care plan:
  • Full breakdown support
  • Full replacement if we can't repair your product within 10 days
  • All parts, labour and callouts included if necessary
  • Extended manufacturer warranty with faster turn arounds
  • Excludes accidental & cosmetic damages
By selecting one of these plans you agree to purchase WME Care Plan. Please read the Terms and Important information to ensure WME Care Plan is right for you. Compare prices of extended warranties for electrical goods at www.compareextendedwarranties.co.uk
WME Care
Technical Details
Specifications
Brand Name
Fike
Manufacturer Part Number
205-0001
Product Type
Smoke Alarm
General information
Application/Usage
Alarm, Control Panel, Fire Alarm, Heat Detector, Smoke Detector
Certifications
WEEE compliance
Compliant
Physical characteristics
Colour
White
Weight
0.25kg
Miscellaneous
Package Contents
ASD Detector With Sounder Base
Attributes
Package Contents
ASD Detector With Sounder Base
Weight
0.25kg

Specifications

Brand Name Fike
Manufacturer Part Number 205-0001
Product Type Smoke Alarm

General information

Application/Usage Alarm, Control Panel, Fire Alarm, Heat Detector, Smoke Detector

Certifications

WEEE compliance Compliant

Physical characteristics

Colour White
Weight 0.25kg

Miscellaneous

Package Contents ASD Detector With Sounder Base

Attributes

Package Contents ASD Detector With Sounder Base
Weight 0.25kg

Fike 205-0001 smoke alarm, white

Fike 205-0001 smoke alarm, White

Who this is for

For the installer — this is the smoke alarm supplied under Fike part number 205-0001. Specify it by that part number.

In plain English: this is a smoke alarm made by Fike. The part number 205-0001 is the manufacturer's own code for this exact version of it.

Similar-looking items in the same family often differ only by a suffix on that code. If you are replacing something, match the code rather than the picture.

Buying this in the UK

We are a UK supplier and this smoke alarm is sold and shipped from the UK. Prices are shown in pounds sterling.

This item is returnable under our standard returns terms. Faulty goods are handled separately and are never affected by a returns restriction.

We do not quote a warranty term for this part.

Ask us and we will check it for you. Your statutory rights are unaffected.

Stock on this line moves, and lead times move with it. Ask us for the current position before you commit to a date on site.

Questions we get asked

Is this the exact smoke alarm I have been quoted? Check the manufacturer part number 205-0001 against your quote. That code is the only reliable identity for this item.

Is there a datasheet? Yes — the documentation attached to this listing was checked and names this exact part number. Documents that named only the family, or a different item, are not attached.

What if I order the wrong version? Tell us the installation you are matching and we will work back to the part number with you. That is a faster conversation than a return.

Fike 205-0001 smoke alarm, white
Fike

Fike 205-0001 smoke alarm, White

£64.86

Fike 205-0001 is a smoke alarm.

The Multipoint ASD detectors have set new standards in detector technology. The Addressable ASD detector is used on the Duonet and Quadnet systems. The detectors can be matched to the environment in which they are installed and changed any time during the lifetime of the installation.

The mode of detection required can be changed simply by configuring the DIL switch in the detector electronics module (configurable via commissioning software on addressable systems). All modes are compliant with European detector type specifications. The Addressable ASD detector offers multiple choices for detection, set to a single mode or a combination, for a choice of up to 15 different settings.

Programmable via a PC or at the panel (Quadnet and Duonet only) and also has an in-built loop isolator as well as I/O for local control and switching. The Multipoint ASD detectors have the unique benefit of an optional full specification integral sounder, where 90dBA output can be achieved. The Addressable ASD detector has 7 different sound patterns and 3 volume settings.

All Multipoint ASD detectors have the option of an integral combined strobe. Modes of Detection

Smoke 1: Used where ionisation detectors are normally fitted, especially when there are high ceilings or a risk of free burning fires (chemical stores etc.) or fires that need to be detected extremely quickly. Smoke 2: Used where optical detectors are normally fitted, when there is a risk of a smouldering fire and for escape routes. Smoke 3: Designed for use in areas that are prone to nuisance alarms.

The reduced sensitivity linked with a time delay feature, means that a higher concentration of smoke needs to be present for a constant time period, before a fire decision is made. For example, this setting is ideal for hotel bedrooms with en-suite shower rooms. Heat 2 (Standard Fixed Temperature – 58ºC approx.): Used where a standard fixed temperature heat detector would normally be fitted, suitable for kitchens etc.

Heat 3 (High Fixed Temperature – 90ºC approx.): Used where a high fixed temperature heat detector would normally be fitted. Suitable for commercial kitchens, boiler rooms etc.To ensure the detection capabilities of the detectors are never compromised they self-calibrate every 6 hours. They also continuously monitor for dust contamination until, depending on the environment, it reaches a point where the chamber becomes saturated.

Before this can develop into a false alarm situation, the panel will indicate that the device in question requires attention.

Key features

View product