Fike Twinflex Manual Call Point, Resettable, with Cover 402-0006
About this product
The Fike 402-0006 is a Twinflex manual call point for raising a fire alarm by hand on Twinflex control panels. It suits installers and maintainers of Twinflex systems. It latches into the alarm position until reset with a special key, it can be flush fitted if required, and a call point cover is included.
Key features
- Stays in alarm until someone resets it – once operated it latches into the alarm position and needs a special key
- Flush fitting without extra parts – each MCP comes supplied with a flush fitting adaptor
- Shows its status at a glance – a single colour red LED indicates activation at a 0.5 Second Interval and End Of Line at a 5 Second Interval
- Set up at the back – End Of Line is set with a DIL switch, a small on/off switch on the rear
- Shares a zone with other Twinflex devices – it may be installed on the same zone as the Multipoint detector/sounder
- Extra protection supplied – a call point cover is included
For installers
- Power: 20 to 35V DC. Zone Current @ 24VDC: Quiescent 50uA, Active 16mA.
- Mounting: standard UK single gang deep (47mm min) back box. Size 88mm x 88mm, depth 52mm standard inc base or 25mm flush mounted.
- Cabling: RED (R) (+) and BLUE (B) (-) Zone In / Out, with E for Zone Screen In / Out.
- Compatibility: Twinflex V1 onwards and TwinflexPro V1 onwards. SLU Rating 3, DLU Rating 16.
- Standards: Approved to EN54 Part 11.
Frequently asked questions
How is it reset after activation?
With a special key. Once operated it latches into the alarm position until it is manually reset.
Can it be flush mounted?
Yes. Each one comes with a flush fitting adaptor, and the depth is then 25mm.
What back box does it need?
A standard UK single gang deep back box, 47mm minimum.
Which fire alarm panels does it work with?
Fike's Twinflex range: Twinflex and TwinflexPro, V1 onwards. Check the panel's documentation before pairing it with anything else.
How is End Of Line set?
With the DIL switch on the rear. ON is enabled and OFF is disabled.
Is a cover included?
Yes. This version includes a call point cover.
-
Download
- 402-0006 datasheet
Specifications
Dimensions
Specifications
| Brand | Fike |
|---|---|
| Model | 402-0006 |
| Manufacturer Part Number (MPN) | 402-0006 |
| Also listed as | 402 0006 |
| Product type | Twinflex Manual Call Point (MCP) |
| Style | Resettable |
| Colour | Red |
| Cover | Includes call point cover |
| Width x Height | 88mm x 88mm |
| Depth, standard inc base | 52mm |
| Depth, flush mounted | 25mm |
| Back box | Standard UK single gang deep (47mm min) |
| Supplied adaptor | Flush fitting adaptor |
| Operating temperature | -10°C to +50°C |
| Voltage range | 20 to 35V DC |
| LED indication, activated | 0.5 Second Interval |
| LED indication, End Of Line | 5 Second Interval |
| System compatibility | Twinflex: V1 onwards; TwinflexPro: V1 onwards |
| Zone Current @ 24VDC, quiescent | 50uA |
| Zone Current @ 24VDC, active | 16mA |
| SLU Rating | 3 |
| DLU Rating | 16 |
| Approvals | Approved to EN54 Part 11 |
| Terminal RED (R) | (+) Zone In / Out |
| Terminal BLUE (B) | (-) Zone In / Out |
| Terminal E | Zone Screen In / Out |
| DIL switch, End Of Line | Enabled ON; Disabled OFF |
Dimensions
| Dimensions | Width x Height 88mm x 88mm; depth standard inc base 52mm; depth flush mounted 25mm |
|---|
Fike Twinflex Manual Call Point, Resettable, with Cover 402-0006