HIKMICRO Thermal Camera, Bi-spectrum Bullet, 160 × 120 Thermal, 5MP Optical, Hybrid Light HM-TD2618-10/G0/T1A
About this product
The HIKMICRO HM-TD2618-10/G0/T1A is a bi-spectrum thermal camera for perimeter protection and early fire prevention at warehouses, parking lots and construction sites. It pairs a 160 × 120 thermal image with a 5MP optical picture, and has smart hybrid light up to 80 m.
Key features
- Finds people and vehicles by heat – 160 × 120 thermal sensor, 12 μm, NETD ≤25 mK (25°C, F1.0)
- Tells people from vehicles – VCA3.0 vehicle/human detection and classification
- Early warning of abnormal heat – temperature exception alarm, -20 °C to 150 °C, ± 8°C
- Picks out fire points – fire detection, up to 10 fire points
- Lights the scene at night – smart hybrid light, white light or IR up to 80 m
- Gives a spoken warning – audible alarm with 2 preset voice alerts and 6 importable alerts
- Spots smoking – smoking detection algorithm
For installers
- Power: PoE (802.3at, class 4) or 12 VDC ± 25% on a two-core terminal block, max. 24W.
- Mounting: DS-1260ZJ junction box included. Optional DS-1275ZJ-S-SUS vertical pole mount and DS-1276ZJ-SUS corner mount. Weight 1710 g.
- Cabling: 1 RJ45 10 M/100 M Ethernet, 1 RS-485, 2 alarm inputs, 2 alarm outputs, 3.5 mm audio in.
- Compatibility: ISAPI, HIKVISION SDK and Open Network Video Interface (Profile S, Profile G, Profile T, Profile M). Check any recorder or platform against these.
- Standards: IP67, IK10, TVS 6000V lightning protection. Working temperature -40°C to 65°C.
In the box
- DS-1260ZJ junction box
Frequently asked questions
How far away can it detect people and vehicles?
Up to 100 m for people and 300 m for vehicles using its video content analysis rules. These are reference figures, and performance may vary with the environment.
Can it replace a fire alarm system?
No. Treat its fire point and temperature exception alarms as an added early warning, and keep the building's fire detection and alarm system as it is.
Is it suitable for coastal or corrosive sites?
Not specifically. This model has no specific anti-corrosion protection, so use it where none is needed.
Does it have white light or only infrared?
Both. It has hybrid light with white light, IR and smart modes, each reaching up to 80 m.
Will it work with my existing recorder?
Usually yes, if the recorder supports Open Network Video Interface Profile S, G, T or M. Smart functions and temperature alarms may not carry over, so check the recorder's own specification.
Can it be powered over PoE?
Yes, but it needs PoE (802.3at, class 4), as the camera can draw up to max. 24W. Check that the switch port can deliver that.
-
Download
- HM-TD2618-10/G0/T1A datasheet
Specifications
Specifications
| Brand | HIKMICRO |
|---|---|
| Model | HM-TD2618-10/G0/T1A |
| Manufacturer Part Number (MPN) | HM-TD2618-10/G0/T1A |
| Thermal image sensor | Vanadium Oxide Uncooled Focal Plane Arrays |
| Thermal resolution | 160 × 120 |
| Pixel pitch | 12 μm |
| Spectral range | 8 μm to 14 μm |
| NETD | ≤25 mK (25°C, F1.0) |
| Thermal focal length | 9.7 mm |
| IFOV | 1.24 mrad |
| Min. focusing distance | 1.5 m |
| Thermal aperture | F1.0 |
| Digital zoom | ×2, ×4 |
| Optical image sensor | 1/2.7" Progressive Scan CMOS |
| Optical resolution | 5MP, 2688 × 1944 |
| Min. illumination | 0.0089 Lux @ (F1.6, AGC ON), 0 Lux with IR |
| Shutter speed | 1 s to 1/100,000 s |
| Optical focal length | 12.4 mm |
| Optical field of view | 24.6° × 14° (H × V) |
| Optical aperture | F1.6 |
| WDR | 120 dB |
| Bi-spectrum image fusion | Display the details of optical channel on thermal channel |
| Picture in picture | Display partial image of thermal channel on the full screen of optical channel |
| Target coloration | Supported in white hot and black hot mode |
| Light supplement | Hybrid (IR, White light or Smart mode) |
| IR distance | Up to 80m |
| White light range | Up to 80 m |
| Visual alarm | Yes. White light alarm with adjustable flashing frequencies |
| Audio alarm | Yes, for two types of audible alarm (VCA and Temperature Exception); 2 preset voice alerts (one for each); 6 importable user-defined voice alerts (6 options shared in the two types) |
| VCA rules | 4 VCA rule types (line crossing, intrusion, region entrance, and region exiting), up to 8 VCA rules in total |
| Temperature measurement | 3 temperature measurement rule types (point, area, line), 21 rules in total |
| Temperature range | -20 °C to 150 °C (-4 °F to 302 °F) |
| Temperature accuracy | ±8°C (±14.4°F) |
| Fire detection | Fire detection, up to 10 fire points detectable |
| Main stream, thermal | 25 fps (1280 × 720, 704 × 576, 640 × 512, 320 × 240) |
| Main stream, optical | 50 Hz: 25 fps (2688 × 1944, 2688 × 1520, 1920 × 1080, 1280 × 720); 60Hz: 30 fps (2688 × 1944, 2688 × 1520, 1920 × 1080, 1280 × 720) |
| Sub-stream, thermal | 25 fps (704 × 576, 640 × 512, 320 × 240) |
| Sub-stream, optical | 50 Hz: 25 fps (704 × 576, 352 × 288); 60 Hz: 30 fps (704 × 480, 352 × 240) |
| Video compression | Main stream: H.265/H.264; sub-stream: H.265/H.264/MJPEG |
| Audio compression | G.722.1/G.711ulaw/G.711alaw/MP2L2/G.726/PCM |
| Color palettes | 17 types |
| Protocols | IPv4/IPv6, HTTP, HTTPS, 802.1x, QoS, FTP, SMTP, UPnP, SNMP, DNS, DDNS, NTP, RTSP, RTCP, RTP, TCP, UDP, IGMP, ICMP, DHCP, PPPoE, Bonjour, SFTP, SRTP |
| Network storage | MicroSD/SDHC/SDXC card (up to 512 G) local storage, NAS (NFS, SMB/CIFS), Auto Network Replenishment (ANR) |
| API | ISAPI, HIKVISION SDK, and third-party management platform, Open Network Video Interface (Profile S, Profile G, Profile T, Profile M), OTAP |
| Simultaneous live view | Up to 20 channels |
| User/host level | Up to 32 users, 3 levels: Administrator, Operator, User |
| Security | User authentication (ID and Password), MAC address binding, HTTPS encryption, IEEE 802.1x (EAP-MD5, EAP-TLS), access control, IP address filtering |
| Client | iVMS-4200, Hik-Connect |
| Alarm input | 2, alarm input (0-5 VDC) |
| Alarm output | 2, alarm output (alarm response actions configurable) |
| Alarm action | SD recording/Relay output/Smart capture/FTP upload/Email linkage |
| Audio input | 1, 3.5 mm Mic in/Line in interface. Line input: 2 - 2.4 V [p-p], output impedance: 1 KΩ ± 10% |
| Audio output | Linear level, impedance: 600 Ω |
| Communication interface | 1, RJ45 10 M/100 M Self-adaptive Ethernet interface; 1, RS-485 interface (half duplex) |
| Web client language | 32 languages |
| Power supply | 12 VDC ± 25%, two-core terminal block; PoE (802.3at, class 4) |
| Power consumption | 12 VDC ± 25%: 1.67A to 2.5 A, max. 24W; PoE (802.3at, class 4): 42.5 V to 57 V, 0.56 A to 0.42 A, max. 24W |
| Working temperature/humidity | Temperature: -40°C to 65°C (-40°F to 149°F); humidity: 95% or less |
| Protection level | IP67, IK10 |
| Surge protection | TVS 6000V lightning protection, surge protection, voltage transient protection |
| Weight | 1710 g |
| Range table | VCA 100 m (humans), 300 m (vehicles); temperature measurement 80 m (0.5 × 0.5 m object), 32.3 m (0.2 × 0.2 m object); fire detection 74.4 m (0.5 × 0.5 m object); smoking detection 14.55 m |
| Detection, recognition, identification | Detection 404 m (humans), 1239 m (vehicles); recognition 101 m (humans), 310 m (vehicles); identification 50 m (humans), 155 m (vehicles) |
| Anti-corrosion level | This model has No Specific PROTECTION |
HIKMICRO Thermal Camera, Bi-spectrum Bullet, 160 × 120 Thermal, 5MP Optical, Hybrid Light HM-TD2618-10/G0/T1A