Hochiki Intrinsically Safe Rate of Rise Heat Detector, ATEX, Ivory DCD-1E-IS

£ 61 07
(Incl. VAT) RRP: £73.28
Save £12.21

About this product

The Hochiki DCD-1E-IS is an intrinsically safe conventional rate of rise heat detector, in an ivory case, for hazardous areas. It suits fire installers working in areas at Category 1 and lower. It has a 60° fixed temperature element, ATEX Ex ia IIC T5 classification and a remote indicator output.

Key features

  • Safe in hazardous areas – intrinsically safe, ATEX II 1G EEx ia IIC T5
  • Covers the most demanding zones – suitable for areas at Category 1 and all lower categories
  • Two ways to detect – rate of rise sensing with a 60° fixed temperature element
  • Easy to see in alarm – twin fire LEDs allow 360° viewing
  • Alarm shown outside the room – remote indicator output
  • Third-party approved – LPCB and GL

For installers

  • Power: operating voltage 15 – 30 V dc, quiescent current (typ) 50 µA, maximum current in alarm 50 mA, fed through a Zener Diode Barrier or a Galvanic Isolator.
  • Mounting: YBN-R/4(IS) electronics free mounting base, 8 mm high, fixing centres 48 ~ 74 mm. Detector 100 mm diameter, 40 mm high, 97 g.
  • Cabling: up to 20 DCD-1E-IS detectors with YBN-R/4 IS bases per barrier circuit. The end-of-line resistor must have a body surface area of 230mm2 or more.
  • Compatibility: any BASEEFA Certified shunt safety Zener Diode Barrier of 30V or less, 200mA or less and 1W or less, or a listed BASEEFA Certified Galvanic Isolator.
  • Standards: ATEX certificate BAS01ATEX1021X, LPCB and GL approved, IP63.

Frequently asked questions

What does intrinsically safe mean here?

It means the detector is certified for use in hazardous atmospheres when it is powered through a certified barrier or isolator, at Category 1, 2 or 3.

Does it need a barrier?

Yes. It must be used with either a Zener Diode Barrier or a Galvanic Isolator, installed to that maker's instructions.

Which base does it use?

The YBN-R/4(IS) electronics free mounting base. That base may only be used with Hochiki intrinsically safe specified detector heads.

How many can go on one circuit?

Up to 20 DCD-1E-IS detectors with YBN-R/4 IS bases on one barrier circuit.

Can it be fitted outdoors?

No. Hochiki detectors are suitable for indoor use only.

Is there a white version?

Yes. The white case version is DCD-1E-IS(WHT); this code is the ivory case.

£ 61 07
RRP: £73.28 Save £12.21
Google Top Quality Store · Rated Exceptional
Ships from United Kingdom
28 days hassle free returns
Secure payment transactions
Price
£61.07 Incl. VAT £73.28
Add a WME Product Care Plan Includes warranty, replacement and repairs backed by WME
Why add a product care plan:
  • Full breakdown support
  • Full replacement if we can't repair your product within 10 days
  • All parts, labour and callouts included if necessary
  • Extended manufacturer warranty with faster turn arounds
  • Excludes accidental & cosmetic damages
By selecting one of these plans you agree to purchase WME Care Plan. Please read the Terms and Important information to ensure WME Care Plan is right for you. Compare prices of extended warranties for electrical goods at www.compareextendedwarranties.co.uk
WME Care
Technical Details
Specifications
Brand
Hochiki
Model
DCD-1E-IS
Manufacturer Part Number (MPN)
DCD-1E-IS
Type
Intrinsically safe conventional rate of rise heat detector
Fixed temperature element
60°
Ordering code
DCD-1E-IS
Colour
Ivory
Case material
ABS
ATEX classification
II 1G EEx ia IIC T5 Tamb=55 °C
ATEX certificate
BAS01ATEX1021X
Hazardous area category
Category 1 (inc all lower categories)
Operating voltage
15 – 30 V dc
Quiescent current (typ)
50 µA
Maximum current in alarm
50 mA
Operating temperature range
-10 °C to + 55 °C
Storage temperature range
-30 °C to + 70 °C
Maximum humidity
95% RH, non condensing (at 40 °C)
Ingress protection rating
IP63
Weight
97 g
Dimensions
100 mm diameter x 40 mm height
Compatible base
YBN-R/4(IS), 8 mm high
Fixing centres
48 ~ 74 mm
Indicators
Twin fire LEDs, 360° viewing; remote indicator output
Approvals
LPCB; GL
Dimensions
Dimensions
100 mm diameter x 40 mm height

Specifications

Brand Hochiki
Model DCD-1E-IS
Manufacturer Part Number (MPN) DCD-1E-IS
Type Intrinsically safe conventional rate of rise heat detector
Fixed temperature element 60°
Ordering code DCD-1E-IS
Colour Ivory
Case material ABS
ATEX classification II 1G EEx ia IIC T5 Tamb=55 °C
ATEX certificate BAS01ATEX1021X
Hazardous area category Category 1 (inc all lower categories)
Operating voltage 15 – 30 V dc
Quiescent current (typ) 50 µA
Maximum current in alarm 50 mA
Operating temperature range -10 °C to + 55 °C
Storage temperature range -30 °C to + 70 °C
Maximum humidity 95% RH, non condensing (at 40 °C)
Ingress protection rating IP63
Weight 97 g
Dimensions 100 mm diameter x 40 mm height
Compatible base YBN-R/4(IS), 8 mm high
Fixing centres 48 ~ 74 mm
Indicators Twin fire LEDs, 360° viewing; remote indicator output
Approvals LPCB; GL

Dimensions

Dimensions 100 mm diameter x 40 mm height

Hochiki DCD-1E-IS intrinsically safe heat detector, angled view, ivory case

Hochiki Intrinsically Safe Rate of Rise Heat Detector, ATEX, Ivory DCD-1E-IS

Overview

This Hochiki heat detector is made for hazardous areas, where an explosive gas atmosphere may be present. It combines rate of rise sensing with a 60° fixed temperature element.

It is meant for areas at Category 1, 2 or 3 that have been classified as hazardous. The case is ivory; a white version is sold separately.

How it works

  • Rate of rise: the detector reacts to a fast climb in temperature, the pattern of a developing fire.
  • Fixed element: the 60° fixed temperature element covers a fire that heats the room slowly.
  • Intrinsic safety: a barrier or isolator in the safe area limits the energy on the detector circuit, so a fault cannot release enough energy to ignite the atmosphere.

Where to use it

It is suitable for installation in Category 1, 2 or 3 hazardous atmospheres, with a maximum ambient temperature of up to 55°C. Hochiki detectors are for indoor use only.

Avoid places with excessive condensation, corrosive gas or flammable dust, and places where obstructions block the air flow to the detector.

What the figures mean in practice

  • Ex ia IIC T5: ia is the highest level of intrinsic safety protection, IIC covers the most easily ignited gas group, and T5 sets the maximum surface temperature class.
  • Up to 20 detectors: one barrier circuit takes up to 20 DCD-1E-IS detectors with their bases, so larger areas need more circuits.
  • IP63: the case resists dust and spraying water, but it is still an indoor device.

Installing it

The installer must follow the certification drawing, and Hochiki recommends that only qualified personnel carry out the installation. The barrier earth for a Zener Diode Barrier needs a high integrity connection; a Galvanic Isolator does not need it.

As a rule, label the intrinsically safe system and keep the certificate details with the fire alarm records.

Planning your system

Each head sits on the Hochiki YBN-R/4(IS) intrinsically safe base, which takes only Hochiki intrinsically safe heads. The white case version is the DCD-1E-IS(WHT) heat detector.

The zone runs back through the barrier to a conventional panel from the range of commercial fire alarm panels. Other rooms outside the hazardous area can use standard heat detectors.

This guide to heat detectors covers rate of rise and fixed temperature detection, and the guide to commercial fire alarm systems explains zones and categories. The wider Hochiki range covers bases and call points.

Hochiki DCD-1E-IS intrinsically safe heat detector, angled view, ivory case
Hochiki

Hochiki Intrinsically Safe Rate of Rise Heat Detector, ATEX, Ivory DCD-1E-IS

£61.07 £73.28

The Hochiki DCD-1E-IS is an intrinsically safe conventional rate of rise heat detector, in an ivory case, for hazardous areas. It suits fire installers working in areas at Category 1 and lower. It has a 60° fixed temperature element, ATEX Ex ia IIC T5 classification and a remote indicator output.

Key features

For installers

Frequently asked questions

What does intrinsically safe mean here?

It means the detector is certified for use in hazardous atmospheres when it is powered through a certified barrier or isolator, at Category 1, 2 or 3.

Does it need a barrier?

Yes. It must be used with either a Zener Diode Barrier or a Galvanic Isolator, installed to that maker's instructions.

Which base does it use?

The YBN-R/4(IS) electronics free mounting base. That base may only be used with Hochiki intrinsically safe specified detector heads.

How many can go on one circuit?

Up to 20 DCD-1E-IS detectors with YBN-R/4 IS bases on one barrier circuit.

Can it be fitted outdoors?

No. Hochiki detectors are suitable for indoor use only.

Is there a white version?

Yes. The white case version is DCD-1E-IS(WHT); this code is the ivory case.