MAGFIRE FLK4PH MAG4P Conventional Fire Kit

Free Delivery
£ 254 30
(Incl. VAT)
3 Years Warranty
MAG4P conventional FIRE KIT
About this product

The MAGFIRE FLK4PH, from ESP's Fire Protection range, is a 4 zone conventional fire alarm kit: a MAG4P 4 zone ABS conventional fire panel with 5 PSD2 optical smoke detectors, 1 FHD2 fixed temperature heat detector, 2 SCP2R resettable call points, 2 BA-2R conventional surface Banshee sounders and a BAT7 12V 7.0ah SLA battery.

Key features

  • MAG4P 4 zone ABS conventional fire panel, 4 detection zones
  • 5 PSD2 optical smoke detectors and 1 FHD2 fixed temperature heat detector, each with a diode base
  • 2 SCP2R resettable call points and 2 BA-2R surface Banshee sounders (76 - 110 dB at 1m, 32 tones)
  • Active end of line monitoring and head removal
  • Unlimited number of call points per zone
  • Integral sound alarm button, class change facility and enable/disable security key
  • One man walk test facility, individual zone/sounder isolate and individual sounder circuit fault ID
  • Standby supply up to 12V 7Ah (battery calculation required); a BAT7 12V 7.0ah SLA battery is in the kit

Frequently asked questions

What is in the FLK4PH kit?

1 x MAG4P 4 zone ABS conventional fire panel, 5 x PSD2 optical smoke detectors, 1 x FHD2 fixed temperature heat detector, 2 x SCP2R resettable call points, 2 x BA-2R conventional surface Banshee sounders and 1 x BAT7 12V 7.0ah SLA battery.

How many call points can each zone have?

An unlimited number.

What standby battery does the panel take?

Up to 12V 7Ah, with battery calculation required. A BAT7 12V 7.0ah SLA battery is in the kit.

How loud are the sounders?

76 - 110 dB at 1m, with 32 tones.

Is the kit EN54 compliant?

Yes. It is EN54 compliant.

£ 254 30
FAST delivery by Order within
Google Top Quality Store · Rated Exceptional
Ships from United Kingdom
28 days hassle free returns
Secure payment transactions
Price
£254.30 Incl. VAT
Add a WME Product Care Plan Includes warranty, replacement and repairs backed by WME
Why add a product care plan:
  • Full breakdown support
  • Full replacement if we can't repair your product within 10 days
  • All parts, labour and callouts included if necessary
  • Extended manufacturer warranty with faster turn arounds
  • Excludes accidental & cosmetic damages
By selecting one of these plans you agree to purchase WME Care Plan. Please read the Terms and Important information to ensure WME Care Plan is right for you. Compare prices of extended warranties for electrical goods at www.compareextendedwarranties.co.uk
WME Care
Technical Details
Specifications
MAG4P - 4 Zone ABS Conventional Fire Panel
1
PSD2 - Optical Smoke Detector
5
Maximum Detectors Per Zone
30
Auxiliary Output
24V DC (300mA fused)
Wiring Type
Conventional
Call Points Per Zone
Unlimited
Power Availability (A)
0.7
Mains Fail Consumption (mA)
50
Standby Supply
Up to 12V 7Ah (Battery Calculation Required)
Sounder 1 & 2
24V (maximum 300mA fused) (each)
Fault/Fire Relay
Volt free 500mA @ 24V (max load)
Sounder 1 Output
24V (max 300mA fused)
Sounder 2 Output
24V (max 300mA fused)
FHD2 - Fixed Temperature Heat Detector
1
SCP2R - Resettable Call Point
2
BA-2R - Conventional Surface Banshee Sounder
2
BAT7 - 12V 7.0ah SLA Battery
1
Battery Type
Sealed Lead Acid
Consumption (Battery)(Ah)
7
Warranty Years
3
Additional Information
Integral sound alarm button; Enable/disable security key; One man walk test facility; Individual sounder circuit fault ID; Individual zone/sounder isolate; Class change’ facility
GTIN
5060224105474
Commodity Code
8531103000
Panel (MAG4P) dimensions (mm)
340 x 290 x 100
Panel (MAG4P) weight (Kg)
2.1 (Without Battery)
Panel (MAG4P) operating temperature (°C)
-5 to +40
Panel (MAG4P) thresholds for zone conditions (mA)
0 - 2 (Fault condition); 2 - 6 (Normal condition); 6 - 110 (Fire condition)
Alarm Zone End of Line (Resistance)(Ω)
10K
Panel (MAG4P), smoke (PSD2) and heat (FHD2) detector relative humidity resistance (%)
93 (±3) (@40˚C)
Smoke (PSD2) and heat (FHD2) detector operating voltage (V DC)
9 - 30
Smoke (PSD2) and heat (FHD2) detector alarm current @ 24V (mA)
49
Smoke detector (PSD2) dimensions (mm)
ø102 x 48 (Including Base)
Smoke detector (PSD2) test facility
Simulated Smoke
Smoke detector (PSD2) cable size (mm²)
0.4 - 2.0 (Twin)
Smoke detector (PSD2) ingress protection
IP30
Smoke detector (PSD2) operating temperature (°C)
-10 to +60
Smoke detector (PSD2) weight (Kg)
0.16
Heat detector (FHD2) dimensions (mm)
ø102 x 48 (Including Base)
Heat detector (FHD2) test facility
Heat Source
Heat detector (FHD2) cable size (mm²)
0.4 - 2.0
Heat detector (FHD2) standby current @ 24v (µA)
<60
Heat detector (FHD2) operating temperature (°C)
-10 to +60
Heat detector (FHD2) weight (Kg)
0.16 (Including Base)
Call point (SCP2R) dimensions (mm)
90 x 57 x 90
Call point (SCP2R) colour
Red
Call point (SCP2R) materials
ABS
Call point (SCP2R) type of the frangible element
A
Call point (SCP2R) nominal operating voltage (V DC)
24
Call point (SCP2R) cable size (mm²)
0.4 - 2.0 (Twin)
Call point (SCP2R) current consumption in alarm state (mA)
38 (24V)
Call point (SCP2R) operating temperature (°C)
-10 to +60
Call point (SCP2R) weight (Kg)
0.15
Sounder (BA-2R) dimensions (mm)
ø90 x 75 (Including Base)
Sounder (BA-2R) colour
Red
Sounder (BA-2R) materials
Flame retardant ABS
Sounder (BA-2R) sound output @ 1m (db)
76 - 110
Sounder (BA-2R) volume levels
3; Low (-20dBA), Medium (-10dBA) & High
Sounder (BA-2R) number of available tones
32
Sounder (BA-2R) cable size (mm²)
0.28 - 2.5
Sounder (BA-2R) current consumption (W)
3 - 30
Sounder (BA-2R) ingress protection
IP45
Sounder (BA-2R) operating temperature (°C)
-25 to +70
Battery (BAT7) dimensions (mm)
151 x 65 x 99
Battery (BAT7) colour
Blue & Grey
Battery (BAT7) materials
ABS
Battery (BAT7) operating temperature (°C)
0 to +40
Battery (BAT7) weight (Kg)
2
Dimensions
Panel (MAG4P) (mm)
340 x 290 x 100
Optical smoke detector (PSD2) (mm)
ø102 x 48 (Including Base)
Heat detector (FHD2) (mm)
ø102 x 48 (Including Base)
Call point (SCP2R) (mm)
90 x 57 x 90
Sounder (BA-2R) (mm)
ø90 x 75 (Including Base)
Battery (BAT7) (mm)
151 x 65 x 99

Specifications

MAG4P - 4 Zone ABS Conventional Fire Panel 1
PSD2 - Optical Smoke Detector 5
Maximum Detectors Per Zone 30
Auxiliary Output 24V DC (300mA fused)
Wiring Type Conventional
Call Points Per Zone Unlimited
Power Availability (A) 0.7
Mains Fail Consumption (mA) 50
Standby Supply Up to 12V 7Ah (Battery Calculation Required)
Sounder 1 & 2 24V (maximum 300mA fused) (each)
Fault/Fire Relay Volt free 500mA @ 24V (max load)
Sounder 1 Output 24V (max 300mA fused)
Sounder 2 Output 24V (max 300mA fused)
FHD2 - Fixed Temperature Heat Detector 1
SCP2R - Resettable Call Point 2
BA-2R - Conventional Surface Banshee Sounder 2
BAT7 - 12V 7.0ah SLA Battery 1
Battery Type Sealed Lead Acid
Consumption (Battery)(Ah) 7
Warranty Years 3
Additional Information Integral sound alarm button; Enable/disable security key; One man walk test facility; Individual sounder circuit fault ID; Individual zone/sounder isolate; Class change’ facility
GTIN 5060224105474
Commodity Code 8531103000
Panel (MAG4P) dimensions (mm) 340 x 290 x 100
Panel (MAG4P) weight (Kg) 2.1 (Without Battery)
Panel (MAG4P) operating temperature (°C) -5 to +40
Panel (MAG4P) thresholds for zone conditions (mA) 0 - 2 (Fault condition); 2 - 6 (Normal condition); 6 - 110 (Fire condition)
Alarm Zone End of Line (Resistance)(Ω) 10K
Panel (MAG4P), smoke (PSD2) and heat (FHD2) detector relative humidity resistance (%) 93 (±3) (@40˚C)
Smoke (PSD2) and heat (FHD2) detector operating voltage (V DC) 9 - 30
Smoke (PSD2) and heat (FHD2) detector alarm current @ 24V (mA) 49
Smoke detector (PSD2) dimensions (mm) ø102 x 48 (Including Base)
Smoke detector (PSD2) test facility Simulated Smoke
Smoke detector (PSD2) cable size (mm²) 0.4 - 2.0 (Twin)
Smoke detector (PSD2) ingress protection IP30
Smoke detector (PSD2) operating temperature (°C) -10 to +60
Smoke detector (PSD2) weight (Kg) 0.16
Heat detector (FHD2) dimensions (mm) ø102 x 48 (Including Base)
Heat detector (FHD2) test facility Heat Source
Heat detector (FHD2) cable size (mm²) 0.4 - 2.0
Heat detector (FHD2) standby current @ 24v (µA) <60
Heat detector (FHD2) operating temperature (°C) -10 to +60
Heat detector (FHD2) weight (Kg) 0.16 (Including Base)
Call point (SCP2R) dimensions (mm) 90 x 57 x 90
Call point (SCP2R) colour Red
Call point (SCP2R) materials ABS
Call point (SCP2R) type of the frangible element A
Call point (SCP2R) nominal operating voltage (V DC) 24
Call point (SCP2R) cable size (mm²) 0.4 - 2.0 (Twin)
Call point (SCP2R) current consumption in alarm state (mA) 38 (24V)
Call point (SCP2R) operating temperature (°C) -10 to +60
Call point (SCP2R) weight (Kg) 0.15
Sounder (BA-2R) dimensions (mm) ø90 x 75 (Including Base)
Sounder (BA-2R) colour Red
Sounder (BA-2R) materials Flame retardant ABS
Sounder (BA-2R) sound output @ 1m (db) 76 - 110
Sounder (BA-2R) volume levels 3; Low (-20dBA), Medium (-10dBA) & High
Sounder (BA-2R) number of available tones 32
Sounder (BA-2R) cable size (mm²) 0.28 - 2.5
Sounder (BA-2R) current consumption (W) 3 - 30
Sounder (BA-2R) ingress protection IP45
Sounder (BA-2R) operating temperature (°C) -25 to +70
Battery (BAT7) dimensions (mm) 151 x 65 x 99
Battery (BAT7) colour Blue & Grey
Battery (BAT7) materials ABS
Battery (BAT7) operating temperature (°C) 0 to +40
Battery (BAT7) weight (Kg) 2

Dimensions

Panel (MAG4P) (mm) 340 x 290 x 100
Optical smoke detector (PSD2) (mm) ø102 x 48 (Including Base)
Heat detector (FHD2) (mm) ø102 x 48 (Including Base)
Call point (SCP2R) (mm) 90 x 57 x 90
Sounder (BA-2R) (mm) ø90 x 75 (Including Base)
Battery (BAT7) (mm) 151 x 65 x 99

MAG4P conventional FIRE KIT features

MAGFIRE FLK4PH MAG4P Conventional Fire Kit

MAGFIRE FLK4PH MAG4P Conventional Fire Kit

What it does

The FLK4PH is a 4 zone conventional fire alarm kit built around the MAG4P 4 zone ABS conventional fire panel, with active end of line monitoring and head removal and an unlimited number of call points per zone. Its features include an integral sound alarm button, a class change facility, an enable/disable security key, a one man walk test facility, individual zone/sounder isolate and individual sounder circuit fault ID.

The kit's detectors are 5 PSD2 optical smoke detectors and 1 FHD2 fixed temperature heat detector, each with a diode base. The 2 BA-2R conventional surface Banshee sounders give 76 - 110 dB at 1m, with 32 tones and 3 volume levels.

Installation notes

The panel's auxiliary output is 24V DC (300mA fused), and its sounder 1 and 2 outputs are each 24V (max 300mA fused). Standby supply is up to 12V 7Ah (battery calculation required), and the kit's BAT7 is a 12V 7.0ah sealed lead acid battery. The fault/fire relay is volt free, 500mA @ 24V (max load), and the alarm zone end of line is 10K.

The detectors run from 9 - 30 V DC and take 0.4 - 2.0 mm² cable. The SCP2R call points have a nominal operating voltage of 24 V DC. The sounders take 0.28 - 2.5 mm² cable and are rated IP45.

The panel measures 340 x 290 x 100 mm and weighs 2.1 kg without battery. Its operating temperature is -5 to +40 °C.

MAGFIRE FLK4PH MAG4P Conventional Fire Kit
ESP

MAGFIRE FLK4PH MAG4P Conventional Fire Kit

£254.30

The MAGFIRE FLK4PH, from ESP's Fire Protection range, is a 4 zone conventional fire alarm kit: a MAG4P 4 zone ABS conventional fire panel with 5 PSD2 optical smoke detectors, 1 FHD2 fixed temperature heat detector, 2 SCP2R resettable call points, 2 BA-2R conventional surface Banshee sounders and a BAT7 12V 7.0ah SLA battery.

Key features

Frequently asked questions

What is in the FLK4PH kit?

1 x MAG4P 4 zone ABS conventional fire panel, 5 x PSD2 optical smoke detectors, 1 x FHD2 fixed temperature heat detector, 2 x SCP2R resettable call points, 2 x BA-2R conventional surface Banshee sounders and 1 x BAT7 12V 7.0ah SLA battery.

How many call points can each zone have?

An unlimited number.

What standby battery does the panel take?

Up to 12V 7Ah, with battery calculation required. A BAT7 12V 7.0ah SLA battery is in the kit.

How loud are the sounders?

76 - 110 dB at 1m, with 32 tones.

Is the kit EN54 compliant?

Yes. It is EN54 compliant.