Patol End of Line Unit, Fire & Fault Test Key Switch, ABS, Digital LHDC 700-576

Free Delivery
£ 358 37
(Incl. VAT) RRP: £430.04
Save £71.67

About this product

The Patol 700-576 is an end of line unit for terminating digital linear heat detection cable, also called LHDC, used with the DDL/DIM-28. It suits fire engineers finishing a heat cable run who want a simple way to test it. It has a fire and fault test key switch in an IP66 ABS box.

Key features

  • Test without disturbing the cable – fire and fault test key switch
  • Watches the cable for breaks – digital end of line units monitor for open circuit faults
  • Matched to its cable and controller – for Digital LHDC with DDL/DIM-28
  • Keeps out dust and water jets – IP66
  • Tough plastic enclosure – ABS, 120 x 120 x 80 mm

For installers

  • Mounting: ABS enclosure, 120 x 120 x 80 mm, IP66.
  • Cabling: 1 x PG 7 gland for the heat cable.
  • Compatibility: Digital LHDC with DDL/DIM-28 only. Resistor values differ for each cable type and controller, so the analogue version is a different part, 700-541.
  • Standards: IP66.

Frequently asked questions

What does an end of line unit do?

It terminates the far end of a linear heat detection cable and provides fault monitoring on the cable.

Which heat cable does the 700-576 suit?

Digital LHDC used with the DDL/DIM-28. For analogue cable, the matching ABS unit is part 700-541.

What faults does it detect?

Open circuit faults on the cable, such as a break.

Can it be used in wet or dusty areas?

It is rated IP66, which is strong protection against dust and water jets. Check it suits the temperature and chemicals on site.

£ 358 37
RRP: £430.04 Save £71.67
Google Top Quality Store · Rated Exceptional
Ships from United Kingdom
28 days hassle free returns
Secure payment transactions
Price
£358.37 Incl. VAT £430.04
Add a WME Product Care Plan Includes warranty, replacement and repairs backed by WME
Why add a product care plan:
  • Full breakdown support
  • Full replacement if we can't repair your product within 10 days
  • All parts, labour and callouts included if necessary
  • Extended manufacturer warranty with faster turn arounds
  • Excludes accidental & cosmetic damages
By selecting one of these plans you agree to purchase WME Care Plan. Please read the Terms and Important information to ensure WME Care Plan is right for you. Compare prices of extended warranties for electrical goods at www.compareextendedwarranties.co.uk
WME Care
Technical Details
Specifications
Brand
Patol
Model
700-576
Manufacturer Part Number (MPN)
700-576
Product type
End of line unit, ABS, with Fire & Fault test key switch
For
Digital LHDC with DDL/DIM-28
Material
ABS
IP Rating
IP66
Dimensions
120 x 120 x 80 mm
Glands
1 x PG 7
Monitoring
Open circuit faults
Dimensions
Dimensions
120 x 120 x 80 mm

Specifications

Brand Patol
Model 700-576
Manufacturer Part Number (MPN) 700-576
Product type End of line unit, ABS, with Fire & Fault test key switch
For Digital LHDC with DDL/DIM-28
Material ABS
IP Rating IP66
Dimensions 120 x 120 x 80 mm
Glands 1 x PG 7
Monitoring Open circuit faults

Dimensions

Dimensions 120 x 120 x 80 mm

Patol 700-576 heat cable end of line unit, front view with key switch

Patol End of Line Unit, Fire & Fault Test Key Switch, ABS, Digital LHDC 700-576

Overview

Linear heat detection cable runs along a route and raises an alarm when it is heated. The far end of the run needs a termination so the system can tell a healthy cable from a broken one.

Its key switch lets an engineer check fire and fault signals at the far end of the run, without opening the box.

How it works

  • End of line monitoring: the unit gives the controller a known condition to watch, so a break in the cable shows as a fault.
  • Key switch: a key-operated switch for fire and fault tests, so only someone holding the key can operate it.

Where to use it

Fit it at the end of each digital heat cable zone. Heat cable is often chosen where point detectors are hard to place or maintain.

The ABS box is rated IP66, so it can suit damp or dirty plant areas.

Installing it

  • Cable entry: bring the cable in through the single PG 7 gland and check the cable's outer diameter suits it.
  • Position: as a rule, mount it where the key switch can be reached for routine tests.
  • Commissioning: test the fire and fault signals at the controller before handing over.

Planning your system

A run of linear heat detection cable also needs its controller and, where the route needs a joint, a junction box such as the Patol 700-508 through connector.

The guide to heat detection explains where heat-based protection is chosen over smoke detection. Most jobs then pass the alarm to the building's fire alarm system, so check the panel's documentation for its input requirements.

Other fire alarm accessories may be needed for the route, such as fixings and fire-rated glands.

Patol 700-576 heat cable end of line unit, front view with key switch
Patol

Patol End of Line Unit, Fire & Fault Test Key Switch, ABS, Digital LHDC 700-576

£358.37 £430.04

The Patol 700-576 is an end of line unit for terminating digital linear heat detection cable, also called LHDC, used with the DDL/DIM-28. It suits fire engineers finishing a heat cable run who want a simple way to test it. It has a fire and fault test key switch in an IP66 ABS box.

Key features

For installers

Frequently asked questions

What does an end of line unit do?

It terminates the far end of a linear heat detection cable and provides fault monitoring on the cable.

Which heat cable does the 700-576 suit?

Digital LHDC used with the DDL/DIM-28. For analogue cable, the matching ABS unit is part 700-541.

What faults does it detect?

Open circuit faults on the cable, such as a break.

Can it be used in wet or dusty areas?

It is rated IP66, which is strong protection against dust and water jets. Check it suits the temperature and chemicals on site.