Texecom Premier Odyssey 4E External Alarm Sounder & Strobe, 109dB, IP44, White/Blue FCD-0209

£ 42 02
(Incl. VAT) RRP: £50.42
Save £8.40

About this product

The Texecom FCD-0209 is a Premier Odyssey 4E external alarm sounder and strobe, in white with a blue lens. It is aimed at residential installations, with a single piezo sounder producing 109dB(A) and an IP44 enclosed electronics module. It is rated Grade 2 Class IV, and has lid and wall tamper detection.

Key features

  • Heard from a distance – single piezo sounder producing 109dB(A)
  • Seen as well as heard – 1Ws Xenon flash tube
  • Safer on the ladder – patented engineer hold-off mode
  • Harder to attack – lid & wall tamper detection
  • Protected electronics – IP44 enclosed electronics module
  • Tough outer case – 3mm polycarbonate
  • Looks active day to day – twin alternating LEDs

For installers

  • Power: supply voltage 12-16 VDC (13.7 nominal). Strobe 100mA, quiescent 18mA.
  • Mounting: external wall, 310mm x 196mm x 58.5mm. Environmental protection IP44, operating temperature -25˚C (-13˚F) to +55˚C (+131˚F).
  • Compatibility: selectable SAB/SCB mode. Check the control panel's documentation for the outputs it provides.
  • Standards: PD6662:2010 Grade 2 Class IV. EN50131-1, EN50131-4 Grade 2 Class IV.

Frequently asked questions

How loud is it?

109dB. That is peak at 1m (A weighting, 90˚) in SAB mode at 13.7VDC.

What grade is it?

Grade 2, Class IV. It is rated to PD6662:2010, and to EN50131-1 and EN50131-4.

What is engineer hold-off mode?

It stops the unit sounding until the tamper circuit is secure. It can also be re-invoked at any time from the control panel.

What voltage does it need?

12-16 VDC, with 13.7 nominal.

How long does it sound for?

Less than 15 minutes. The stated cut-off time is <15 minutes.

Does it have a backup battery?

Yes. It has an integrated backup battery, type NiMh stack at 7.2VDC (nominal), 250mAh.

£ 42 02
RRP: £50.42 Save £8.40
Google Top Quality Store · Rated Exceptional
Ships from United Kingdom
28 days hassle free returns
Secure payment transactions
Price
£42.02 Incl. VAT £50.42
Add a WME Product Care Plan Includes warranty, replacement and repairs backed by WME
Why add a product care plan:
  • Full breakdown support
  • Full replacement if we can't repair your product within 10 days
  • All parts, labour and callouts included if necessary
  • Extended manufacturer warranty with faster turn arounds
  • Excludes accidental & cosmetic damages
By selecting one of these plans you agree to purchase WME Care Plan. Please read the Terms and Important information to ensure WME Care Plan is right for you. Compare prices of extended warranties for electrical goods at www.compareextendedwarranties.co.uk
WME Care
Technical Details
Specifications
Brand
Texecom
Model
FCD-0209
Manufacturer Part Number (MPN)
FCD-0209
Also listed as
Premier Odyssey 4E
Product type
External Sounder & Strobe Unit
Colour
White/Blue
Supply voltage
12-16 VDC (13.7 nominal)
Strobe current
100mA
Quiescent current
18mA
Standby battery type
NiMh Stack
Standby battery voltage
7.2VDC (nominal)
Standby battery capacity
250mAh
Flash tube
1Ws Xenon
Flash rate
1Hz (typical)
Discharge time (<60VDC)
<180 seconds
Comfort LED brightness
100mcd (typical)
Comfort LED flash rate (tamper secure)
1Hz alternating (typical)
Volume (SAB mode at 13.7VDC)
109dB Peak at 1m (A Weighting, 90˚)
Cut-off time
<15 minutes
Environmental protection
IP44
Operating temperature
-25˚C (-13˚F) to +55˚C (+131˚F)
Storage temperature
-25˚C (-13˚F) to +60˚C (+140˚F)
EMC environment
Residential / Commercial / Industrial
Material
3mm polycarbonate
Tamper detection
Wall & lid
Dimensions (h x w x d)
310mm x 196mm x 58.5mm
Standards
PD6662:2010 Grade 2 Class IV; EN50131-1, EN50131-4 Grade 2 Class IV
EMC approvals
BS EN 55022 Class B and BS EN 50130-4 : 1996
Dimensions
Dimensions
310mm x 196mm x 58.5mm

Specifications

Brand Texecom
Model FCD-0209
Manufacturer Part Number (MPN) FCD-0209
Also listed as Premier Odyssey 4E
Product type External Sounder & Strobe Unit
Colour White/Blue
Supply voltage 12-16 VDC (13.7 nominal)
Strobe current 100mA
Quiescent current 18mA
Standby battery type NiMh Stack
Standby battery voltage 7.2VDC (nominal)
Standby battery capacity 250mAh
Flash tube 1Ws Xenon
Flash rate 1Hz (typical)
Discharge time (<60VDC) <180 seconds
Comfort LED brightness 100mcd (typical)
Comfort LED flash rate (tamper secure) 1Hz alternating (typical)
Volume (SAB mode at 13.7VDC) 109dB Peak at 1m (A Weighting, 90˚)
Cut-off time <15 minutes
Environmental protection IP44
Operating temperature -25˚C (-13˚F) to +55˚C (+131˚F)
Storage temperature -25˚C (-13˚F) to +60˚C (+140˚F)
EMC environment Residential / Commercial / Industrial
Material 3mm polycarbonate
Tamper detection Wall & lid
Dimensions (h x w x d) 310mm x 196mm x 58.5mm
Standards PD6662:2010 Grade 2 Class IV; EN50131-1, EN50131-4 Grade 2 Class IV
EMC approvals BS EN 55022 Class B and BS EN 50130-4 : 1996

Dimensions

Dimensions 310mm x 196mm x 58.5mm

Texecom Premier Odyssey 4E infographic. Signal an intrusion alarm. 109 dB sounder.
Signal an intrusion alarm. 109 dB sounder. Give an audible indication outside the building.
Texecom Premier Odyssey 4E infographic. Add a visual warning. Integrated strobe.
Add a visual warning. Integrated strobe. The strobe provides a visible alarm signal.

Texecom Premier Odyssey 4E External Alarm Sounder & Strobe, 109dB, IP44, White/Blue FCD-0209

Overview

An external sounder does two jobs. It warns the neighbourhood during an alarm, and the box on the wall shows that the building has an alarm system at all.

It is aimed at residential installations. Browse other Texecom sounders.

How it works

  • Sound: A single piezo sounder gives the alarm tone.
  • Strobe: The xenon flash tube helps responders find the right building.
  • Hold-off: The patented mode stops the unit sounding until the tamper circuit is secure, so the lid can be fitted without setting it off.
  • Comfort LEDs: The twin alternating LEDs flash while the tamper is secure, so the unit looks active day to day.

Where to use it

Class IV is the outdoor class, and the operating range runs from -25˚C to +55˚C. The electronics module is enclosed to IP44, a lower rating than sealed modules, so mount it on a wall and not where water can pool on it.

As a rule, fit it high up on the front of the building, where it can be seen from the street and is hard to reach.

What the figures mean in practice

  • 109dB peak at 1m: Measured close to the unit. It will sound quieter further away, so consider a second sounder on a large site.
  • Under 15 minutes: Cut-off keeps the alarm within a set time.
  • Quiescent 18mA: Add this to the panel's standby load when working out battery size.

Installing it

  • Tamper switch: The adjustable wall & lid tamper switch needs setting so it closes firmly once the lid is on. Test both before leaving site.
  • SAB or SCB: Set the mode to match the panel's output. SAB usually means the sounder runs off its own battery when triggered, while SCB is a simpler single command wiring.
  • Access: In most cases this is a ladder job, so plan safe access first. The article on common installation mistakes also covers bell boxes.

Planning your system

The sounder needs a control panel to trigger it. Compare alarm panels, and check that panel's documentation for the output types it provides.

The wider sounders and bell boxes range has other styles, if this one does not suit the building.

Standards and ratings explained

Grade 2 is generally used on homes and lower risk commercial sites, and PD6662 is the British scheme applying the European standard. The article on the British standard for intruder alarms explains these grades.

Texecom FCD-0209 external alarm sounder, front view
Texecom

Texecom Premier Odyssey 4E External Alarm Sounder & Strobe, 109dB, IP44, White/Blue FCD-0209

£42.02 £50.42

The Texecom FCD-0209 is a Premier Odyssey 4E external alarm sounder and strobe, in white with a blue lens. It is aimed at residential installations, with a single piezo sounder producing 109dB(A) and an IP44 enclosed electronics module. It is rated Grade 2 Class IV, and has lid and wall tamper detection.

Key features

For installers

Frequently asked questions

How loud is it?

109dB. That is peak at 1m (A weighting, 90˚) in SAB mode at 13.7VDC.

What grade is it?

Grade 2, Class IV. It is rated to PD6662:2010, and to EN50131-1 and EN50131-4.

What is engineer hold-off mode?

It stops the unit sounding until the tamper circuit is secure. It can also be re-invoked at any time from the control panel.

What voltage does it need?

12-16 VDC, with 13.7 nominal.

How long does it sound for?

Less than 15 minutes. The stated cut-off time is <15 minutes.

Does it have a backup battery?

Yes. It has an integrated backup battery, type NiMh stack at 7.2VDC (nominal), 250mAh.

View product