Urmet 1148/46 access control keypad

Free Delivery
£ 236 97
(Incl. VAT)

About this product

Please note: this is a non-returnable item (excluding faulty goods)

The Urmet 1148/46 is the Sinthesi S2 coded access keypad: a door release digital keypad with 2 relay outputs, for use in the Sinthesi modular range of panels. It stores up to 22 access codes and opens 2 electric locks independently.

Key features

  • Sinthesi S2 coded access keypad for the Sinthesi modular range of panels
  • Up to 22 programmable user codes, each from 3 to 8 digits
  • Two relay door lock contacts for two entrances, operated independently by the programmed codes
  • Each relay programmable for monostable or toggle (bistable) operation, with its own activation time
  • 12 back-lit LED buttons
  • Timeslot management, using a timer (not included)
  • Power 12 Vac or Vdc ± 10%; maximum switchable relay load 12 Vac / 24 Vdc 5A
  • Replaces 1105/3 & 1105/2

Frequently asked questions

How many codes does it store?

Up to 22 access codes, each from 3 to 8 digits.

Does it have a default code?

No: there are no default codes in the 1148/46 keypad, and Urmet do not have any record of the Engineer's Password.

Can it control two doors?

Yes: it has two relay door lock contacts for two entrances, operated independently by the programmed codes; the maximum switchable relay load is 12 Vac / 24 Vdc 5A.

What power does it need?

12 Vac or Vdc ± 10%, with a maximum draw of 250 mA @ 12 Vac or 150 mA @ 12 Vdc.

What does it replace?

1105/3 & 1105/2.

How is it reset?

Disconnect power, hold the programming switch next to the terminal board pressed, power the device while the switch is pressed and release it after about 5 seconds. All the previously programmed codes, times and passwords are deleted.

£ 236 97
Google Top Quality Store · Rated Exceptional
Ships from United Kingdom
28 days hassle free returns
Secure payment transactions
Price
£236.97 Incl. VAT
Add a WME Product Care Plan Includes warranty, replacement and repairs backed by WME
Why add a product care plan:
  • Full breakdown support
  • Full replacement if we can't repair your product within 10 days
  • All parts, labour and callouts included if necessary
  • Extended manufacturer warranty with faster turn arounds
  • Excludes accidental & cosmetic damages
By selecting one of these plans you agree to purchase WME Care Plan. Please read the Terms and Important information to ensure WME Care Plan is right for you. Compare prices of extended warranties for electrical goods at www.compareextendedwarranties.co.uk
WME Care
Technical Details
Specifications
Brand Name
Urmet
Manufacturer Part Number
1148/46
Product Type
Access Control Keypad
Power Voltage
12 Vac or Vdc ± 10%
Maximum Draw
250 mA @ 12 Vac / 150 mA @ 12 Vdc
Maximum Stand-by Consumption
100 mA @ 12 Vac / 50 mA @ 12 Vdc
Maximum Switchable Relay Load
12 Vac / 24 Vdc 5A
User Codes
22
Buttons
12 back-lit LED
Replaces
1105/3 & 1105/2
Technical information
Connectivity Technology
Wired

Specifications

Brand Name Urmet
Manufacturer Part Number 1148/46
Product Type Access Control Keypad
Power Voltage 12 Vac or Vdc ± 10%
Maximum Draw 250 mA @ 12 Vac / 150 mA @ 12 Vdc
Maximum Stand-by Consumption 100 mA @ 12 Vac / 50 mA @ 12 Vdc
Maximum Switchable Relay Load 12 Vac / 24 Vdc 5A
User Codes 22
Buttons 12 back-lit LED
Replaces 1105/3 & 1105/2

Technical information

Connectivity Technology Wired

Urmet 1148/46 access control keypad

Urmet 1148/46 access control keypad

What it is

The 1148/46 is Urmet's Sinthesi S2 coded access keypad — in its installation manual, a door release digital keypad with 2 outputs — for use in the Sinthesi modular range of panels. It replaces 1105/3 & 1105/2.

It manages two entrances with two relay door lock contacts, which may be operated independently using either of the programmed codes, and it stores up to 22 access codes. Its 12 back-lit LED buttons have the numbers 0 to 9 in green. It can be connected to NO buttons (hall button).

Relays and codes

Each relay can be programmed for monostable or toggle operation, with an activation time from 1 second to 99 seconds, or 200ms for toggle operation. By default both relays are monostable with an activation time of 200 ms, and the timeslot terminal is off.

Codes are stored in memory locations 01 to 22, and each activation code is from 3 to 8 digits. With the timeslot function enabled, a timer (not included) may be used to program the periods of the day when the relays can be activated simply by pressing one keypad button.

Electrical

Power voltage is 12 Vac or Vdc ± 10%. Maximum draw is 250 mA @ 12 Vac or 150 mA @ 12 Vdc, and maximum stand-by consumption is 100 mA @ 12 Vac or 50 mA @ 12 Vdc. The maximum switchable relay load is 12 Vac / 24 Vdc 5A.

Programming

The master (Engineer's) password is set by pressing the programming switch next to the terminal board three times in 6 seconds and entering a code from 3 to 8 digits. There are no default codes in the 1148/46 keypad, and Urmet do not have any record of the Engineer's Password; the door open code can be from 3 to 8 digits.

To reset, disconnect power, hold the programming switch next to the terminal board pressed, power the device while the switch is pressed and release it after about 5 seconds: all the previously programmed codes, times and passwords are deleted.

Buying this in the UK

This item is non-returnable, excluding faulty goods.

We do not quote a warranty term for this part.

Ask us and we will check it for you. Your statutory rights are unaffected.

Urmet 1148/46 access control keypad
Urmet

Urmet 1148/46 access control keypad

£236.97

Please note: this is a non-returnable item (excluding faulty goods)

The Urmet 1148/46 is the Sinthesi S2 coded access keypad: a door release digital keypad with 2 relay outputs, for use in the Sinthesi modular range of panels. It stores up to 22 access codes and opens 2 electric locks independently.

Key features

Frequently asked questions

How many codes does it store?

Up to 22 access codes, each from 3 to 8 digits.

Does it have a default code?

No: there are no default codes in the 1148/46 keypad, and Urmet do not have any record of the Engineer's Password.

Can it control two doors?

Yes: it has two relay door lock contacts for two entrances, operated independently by the programmed codes; the maximum switchable relay load is 12 Vac / 24 Vdc 5A.

What power does it need?

12 Vac or Vdc ± 10%, with a maximum draw of 250 mA @ 12 Vac or 150 mA @ 12 Vdc.

What does it replace?

1105/3 & 1105/2.

How is it reset?

Disconnect power, hold the programming switch next to the terminal board pressed, power the device while the switch is pressed and release it after about 5 seconds. All the previously programmed codes, times and passwords are deleted.