Yuasa REC14-12 12V 14Ah Cyclic AGM VRLA Battery, Faston 6.35mm

£ 46 37
(Incl. VAT) RRP: £55.64
Save £9.27

About this product

The Yuasa REC14-12 is a 12V 14Ah cyclic AGM VRLA battery for equipment that is discharged and recharged regularly. It suits buyers who need a sealed battery built for repeated cycling. It gives 14 Ah at the 20-hour rate, about 500 cycles at 75% depth of discharge, and has 6.35mm Faston terminals.

Key features

  • Built for repeated cycling – REC series cyclic AGM VRLA design
  • Hundreds of cycles – 500 cycles at 75% depth of discharge, 1400 at 25%, each to 80% capacity
  • Long design life – up to 10 years at 20°C
  • Strong short bursts – 195 A maximum for 1 second, 70 A for 1 minute
  • Holds its charge in storage – about 3% capacity loss per month at 20°C
  • Quick to connect – 6.35mm Faston terminals

For installers

  • Power: 12 V nominal; 14 Ah at the 20-hour rate, 11.6 Ah at the 10-hour rate.
  • Charging: cyclic or boost 14.52 V per block (±3%) at 20°C; float 13.65 V (±1%); charge current limit 3.25 A.
  • Cabling: 6.35mm Faston terminals.
  • Mounting: 151 x 98 x 94 mm, 4.2 kg; upright or up to 90° from upright, never in a sealed container.
  • Standards: Underwriters Laboratories certification.

Frequently asked questions

How many cycles will the REC14-12 give?

About 500 cycles at 75% depth of discharge, down to 80% capacity. Shallower use gives more: 600 at 50% and 1400 at 25%.

What charge voltage does it need for cyclic use?

14.52 V per block (±3%) at 20°C, with the charge current limited to 3.25 A.

Is it a 14Ah battery?

Yes. It gives 14 Ah at the 20-hour rate to 1.75V per cell at 20°C.

What terminals does it have?

6.35mm Faston terminals.

What temperature range does it work in?

It charges, discharges and stores from -15°C to +45°C.

£ 46 37
RRP: £55.64 Save £9.27
Google Top Quality Store · Rated Exceptional
Ships from United Kingdom
28 days hassle free returns
Secure payment transactions
Price
£46.37 Incl. VAT £55.64
Add a WME Product Care Plan Includes warranty, replacement and repairs backed by WME
Why add a product care plan:
  • Full breakdown support
  • Full replacement if we can't repair your product within 10 days
  • All parts, labour and callouts included if necessary
  • Extended manufacturer warranty with faster turn arounds
  • Excludes accidental & cosmetic damages
By selecting one of these plans you agree to purchase WME Care Plan. Please read the Terms and Important information to ensure WME Care Plan is right for you. Compare prices of extended warranties for electrical goods at www.compareextendedwarranties.co.uk
WME Care
Technical Details
Specifications
Brand
Yuasa
Model
REC14-12
Manufacturer Part Number (MPN)
REC14-12
Product
REC series cyclic AGM VRLA battery
Nominal voltage
12 V
20-hr rate capacity to 1.75V/cell at 20°C
14 Ah
10-hr rate capacity to 1.8V/cell at 20°C
11.6 Ah
10 min constant power to 9.6V at 20°C
447.619 W per block (typical)
Length
151 (±1) mm
Width
98 (±1) mm
Height
94 (±2) mm
Weight
4.2 kg
Terminal type
Faston 6.35mm
Storage, charge and discharge temperature
-15°C to +45°C
Capacity loss per month at 20°C
3% approx.
Case material
ABS (UL94:HB), standard case
Float charge voltage at 20°C
13.65 V per block, 2.275 V per cell (±1%)
Cyclic (or boost) charge voltage at 20°C
14.52 V per block, 2.42 V per cell (±3%)
Float charge temperature correction
-3 mV from standard 20°C
Cyclic charge temperature correction
-4 mV from standard 20°C
Charge current limit (float and cyclic)
3.25 A
Maximum discharge current
195 A for 1 s; 70 A for 1 min
Internal resistance at 1 kHz
10.1 mΩ
Cycle life to 80% capacity
300 at 100% DOD; 500 at 75% DOD; 600 at 50% DOD; 1400 at 25% DOD
EUROBAT classification
Not classified
Yuasa design life at 20°C
Up to 10 years
Certification
Underwriters Laboratories Inc.
Dimensions
Dimensions
151 x 98 x 94 mm (L x W x H)

Specifications

Brand Yuasa
Model REC14-12
Manufacturer Part Number (MPN) REC14-12
Product REC series cyclic AGM VRLA battery
Nominal voltage 12 V
20-hr rate capacity to 1.75V/cell at 20°C 14 Ah
10-hr rate capacity to 1.8V/cell at 20°C 11.6 Ah
10 min constant power to 9.6V at 20°C 447.619 W per block (typical)
Length 151 (±1) mm
Width 98 (±1) mm
Height 94 (±2) mm
Weight 4.2 kg
Terminal type Faston 6.35mm
Storage, charge and discharge temperature -15°C to +45°C
Capacity loss per month at 20°C 3% approx.
Case material ABS (UL94:HB), standard case
Float charge voltage at 20°C 13.65 V per block, 2.275 V per cell (±1%)
Cyclic (or boost) charge voltage at 20°C 14.52 V per block, 2.42 V per cell (±3%)
Float charge temperature correction -3 mV from standard 20°C
Cyclic charge temperature correction -4 mV from standard 20°C
Charge current limit (float and cyclic) 3.25 A
Maximum discharge current 195 A for 1 s; 70 A for 1 min
Internal resistance at 1 kHz 10.1 mΩ
Cycle life to 80% capacity 300 at 100% DOD; 500 at 75% DOD; 600 at 50% DOD; 1400 at 25% DOD
EUROBAT classification Not classified
Yuasa design life at 20°C Up to 10 years
Certification Underwriters Laboratories Inc.

Dimensions

Dimensions 151 x 98 x 94 mm (L x W x H)

Yuasa REC14-12 12V 14Ah cyclic battery, front view

Yuasa REC14-12 12V 14Ah Cyclic AGM VRLA Battery, Faston 6.35mm

Overview

A cyclic battery is made to be run down and recharged again and again, rather than sitting on float charge. The REC series is Yuasa's cyclic range of sealed AGM VRLA batteries.

AGM means the electrolyte is held in glass mat separators, so there is no free liquid to spill and no topping up.

How it works

  • Valve regulated: each cell has a low pressure release valve that lets gas escape and then reseals.
  • Depth of discharge: this is how much of the capacity is used before recharging. The shallower each cycle, the more cycles the battery delivers.

Where to use it

Choose it for equipment that runs from the battery day to day and is then recharged, rather than for pure standby duty. For standby duty, a standby battery is usually the better match.

Its working range is -15°C to +45°C for charge, discharge and storage, so keep it out of very hot or freezing spaces.

What the figures mean in practice

  • Cycle table: used fully every time, it reaches 80% capacity after about 300 cycles. Kept to a quarter of capacity per cycle, that rises to around 1400.
  • 20-hour versus 10-hour capacity: the battery gives more when discharged slowly, which is why the 20-hour figure is higher.
  • Charge voltage: a charger set for cyclic use runs at a higher voltage than float. As a rule, use a charger made for cyclic lead acid batteries.

Installing it

Fit it upright or at up to 90° from upright, and never inside a sealed container, because VRLA batteries can release hydrogen gas.

Connect red to positive and black to negative on the Faston terminals, and check charger output with a meter after fitting.

Planning your system

Size the battery from the load current and the run time needed, then allow margin for ageing. A matching battery charger keeps cycle life close to the figures above.

Other sizes and chemistries are in the specialist and industrial batteries range, and the Yuasa batteries range covers standby models too. A battery tester helps confirm health between cycles.

For other sizes and chemistries, browse the wider batteries and power supplies range.

Standards and ratings explained

  • EUROBAT: an industry class for the float life of standby batteries. This cyclic battery is not classified.
  • UL94:HB: a flammability rating for the plastic case; HB is the standard grade, not a flame retardant case.
Yuasa REC14-12 12V 14Ah cyclic battery, front view
Yuasa

Yuasa REC14-12 12V 14Ah Cyclic AGM VRLA Battery, Faston 6.35mm

£46.37 £55.64

The Yuasa REC14-12 is a 12V 14Ah cyclic AGM VRLA battery for equipment that is discharged and recharged regularly. It suits buyers who need a sealed battery built for repeated cycling. It gives 14 Ah at the 20-hour rate, about 500 cycles at 75% depth of discharge, and has 6.35mm Faston terminals.

Key features

For installers

Frequently asked questions

How many cycles will the REC14-12 give?

About 500 cycles at 75% depth of discharge, down to 80% capacity. Shallower use gives more: 600 at 50% and 1400 at 25%.

What charge voltage does it need for cyclic use?

14.52 V per block (±3%) at 20°C, with the charge current limited to 3.25 A.

Is it a 14Ah battery?

Yes. It gives 14 Ah at the 20-hour rate to 1.75V per cell at 20°C.

What terminals does it have?

6.35mm Faston terminals.

What temperature range does it work in?

It charges, discharges and stores from -15°C to +45°C.