The C-TEC BF326/RSL is a lockable mains isolator keyswitch for the mains supply to a fire alarm panel. It suits installers who need a BS 5839-1 isolator with a power indicator. It is double-pole, has an internal 5A fuse and a green POWER LED, and comes red with a surface back box.

Key features

  • Locks the panel supply on or off – lockable double-pole switch, as BS 5839-1 asks
  • Shows the supply is on – green POWER LED lights in the on position
  • Protected supply – internal 5A ceramic fast blow fuse
  • Only the responsible person can switch it – key removes in either position
  • Clearly marked – front reads FIRE ALARM. DO NOT SWITCH OFF
  • Ready for surface fixing – supplied 1 gang back box

For installers

  • Power: 230Va.c. mains; up to 5A, limited by the internal fuse.
  • Cabling: 1 x 2.5mm² or 2 x 1.5mm² cable, so the panel keeps an independent sole mains supply. Terminals marked L, N and Earth.
  • Mounting: surface, on the supplied back box; two M3.5 x 40mm screws supplied.
  • Compatibility: all C-TEC mains control panels, plus 3rd party single phase panels with a maximum load of 5A or less.
  • Standards: BS 5839-1 and BS 8629 marking; designed to comply with BS EN 60669-1 & BS EN 60669-2-4. IP30, indoor use only.

In the box

  • BF326/RSL mains isolator keyswitch with LED
  • 1 gang surface back box
  • 2 x C-TEC red plastic fire keys
  • 2 x M3.5 x 40mm fixing screws

Frequently asked questions

What is the BF326/RSL used for?

It lets the mains supply to a fire alarm panel be locked on and off, as BS 5839-1 asks. That makes routine work such as battery tests and main board changes safer.

Does it work with panels from other makers?

Yes, with 3rd party single phase control panels if the maximum load is 5A or less, as well as all C-TEC mains panels.

How do the key positions work?

Turn the key horizontal to switch the power on, and vertical to switch it off. The green POWER LED lights when it is on.

Can it be used on an evacuation alert or EVC system?

Yes. Fit the BF326/LABEL to the front so it reads correctly for that system.

Can it be fitted outdoors?

No. It is rated IP30 for indoor use only.

£ 17 75
RRP: £21.30 Save £3.55
Google Top Quality Store · Rated Exceptional
Ships from United Kingdom
28 days hassle free returns
Secure payment transactions
Price
£17.75 Incl. VAT £21.30
Add a WME Product Care Plan Includes warranty, replacement and repairs backed by WME
Why add a product care plan:
  • Full breakdown support
  • Full replacement if we can't repair your product within 10 days
  • All parts, labour and callouts included if necessary
  • Extended manufacturer warranty with faster turn arounds
  • Excludes accidental & cosmetic damages
By selecting one of these plans you agree to purchase WME Care Plan. Please read the Terms and Important information to ensure WME Care Plan is right for you. Compare prices of extended warranties for electrical goods at www.compareextendedwarranties.co.uk
WME Care
Technical Details
Specifications
Brand
C-TEC
Model
BF326/RSL
Manufacturer Part Number (MPN)
BF326/RSL
Product
Mains isolator keyswitch, red, surface, with LED and back box
Switch type
Double-pole, lockable on and off
Operating voltage
230Va.c.
Current @ 230V
5A (limited by internal fuse)
Internal fuse
5A ceramic fast blow (F 5AH 250V) high rupturing capacity
Indicator
Green POWER LED, lit in the on position
Key
C-TEC red plastic fire key, 2 supplied
Cable
1 x 2.5mm² or 2 x 1.5mm²
Compatible panels
All C-TEC mains control panels; 3rd party single phase panels with maximum load 5A or less
Front marking
FIRE ALARM. DO NOT SWITCH OFF
Fixing screws
M3.5 x 40mm, 2 supplied
Body material / colour
Red PVC RAL3001
Weight (surface mounted)
170g
Humidity
Max. 95% RH (non-condensing)
IP rating (EN 60529)
IP30 (indoor use only)
Standards
BS 5839-1; BS 8629; BS EN 60669-1; BS EN 60669-2-4

Specifications

Brand C-TEC
Model BF326/RSL
Manufacturer Part Number (MPN) BF326/RSL
Product Mains isolator keyswitch, red, surface, with LED and back box
Switch type Double-pole, lockable on and off
Operating voltage 230Va.c.
Current @ 230V 5A (limited by internal fuse)
Internal fuse 5A ceramic fast blow (F 5AH 250V) high rupturing capacity
Indicator Green POWER LED, lit in the on position
Key C-TEC red plastic fire key, 2 supplied
Cable 1 x 2.5mm² or 2 x 1.5mm²
Compatible panels All C-TEC mains control panels; 3rd party single phase panels with maximum load 5A or less
Front marking FIRE ALARM. DO NOT SWITCH OFF
Fixing screws M3.5 x 40mm, 2 supplied
Body material / colour Red PVC RAL3001
Weight (surface mounted) 170g
Humidity Max. 95% RH (non-condensing)
IP rating (EN 60529) IP30 (indoor use only)
Standards BS 5839-1; BS 8629; BS EN 60669-1; BS EN 60669-2-4

C-TEC BF326/RSL mains isolator keyswitch, front view

C-TEC BF326/RSL Fire Alarm Mains Isolator Keyswitch with LED, Surface, Red

Overview

A fire alarm panel needs a mains supply that cannot be switched off by accident, but which an engineer can isolate safely for maintenance. This keyswitch does both: it locks the supply on or off, and only the responsible person holds the key.

The RSL version is red, surface mounted with its own back box, and has a green POWER LED.

How it works

  • Double-pole switching: both live and neutral are broken when the key is turned off, so the panel supply is fully isolated.
  • Internal fuse: a 5A fast blow fuse limits the current to the panel.
  • Power indicator: the LED confirms the supply is switched on without opening anything.

Where to use it

Fit it on the dedicated mains supply to a fire alarm panel, an EVAC Alert panel or an Emergency Voice Communication panel, usually close to the panel. It is for indoor use only (IP30).

What the figures mean in practice

  • 5A limit: check the panel's maximum mains load before fitting it to another maker's panel; above 5A it is not suitable.
  • Cable sizes: the terminals take one 2.5mm² cable or two 1.5mm² cables, so the supply can stay independent.

Installing it

Mains work must follow the IET Wiring Regulations (BS 7671) and a safe isolation procedure. For complete details, read BS 5839-1 Clause 25.2 or BS 8629 Clause 14.2.

Earth terminals are provided for convenience. Run the supply in fire resistant cable where the system design calls for it.

Planning your system

On an evacuation alert or voice system, order the BF326/LABEL so the front reads correctly. The BF326/RS is the same red surface keyswitch without the LED.

For the panel itself, see the commercial fire alarm panels range, and the fire alarm system guide explains categories and zones. More C-TEC products cover sounders, detectors and kits.

Standards and ratings explained

  • BS 5839-1: the code of practice for fire detection and fire alarm systems for buildings, which sets the rules for the panel's mains supply.
  • BS EN 60669-2-4: the part of the switch standard covering isolating switches.
C-TEC BF326/RSL mains isolator keyswitch, front view
C-TEC

C-TEC BF326/RSL Fire Alarm Mains Isolator Keyswitch with LED, Surface, Red

£17.75 £21.30

The C-TEC BF326/RSL is a lockable mains isolator keyswitch for the mains supply to a fire alarm panel. It suits installers who need a BS 5839-1 isolator with a power indicator. It is double-pole, has an internal 5A fuse and a green POWER LED, and comes red with a surface back box.

Key features

For installers

In the box

Frequently asked questions

What is the BF326/RSL used for?

It lets the mains supply to a fire alarm panel be locked on and off, as BS 5839-1 asks. That makes routine work such as battery tests and main board changes safer.

Does it work with panels from other makers?

Yes, with 3rd party single phase control panels if the maximum load is 5A or less, as well as all C-TEC mains panels.

How do the key positions work?

Turn the key horizontal to switch the power on, and vertical to switch it off. The green POWER LED lights when it is on.

Can it be used on an evacuation alert or EVC system?

Yes. Fit the BF326/LABEL to the front so it reads correctly for that system.

Can it be fitted outdoors?

No. It is rated IP30 for indoor use only.

View product