C-TEC Quantec Monitoring Point, Keyswitch Isolation, Button Reset QT604

£ 52 56
(Incl. VAT) RRP: £63.07
Save £10.51

About this product

The C-TEC QT604 is a Quantec monitoring point for nurse call systems. It watches a fire exit, a drug cupboard or any normally open or closed switch, and raises a Standard or Emergency call. An isolation keyswitch switches monitoring off when needed, and a RESET button cancels calls.

Key features

  • Turns a switch into a call – monitors any device with a normally open or normally closed switch
  • Choose the call level – configured to generate a Standard or Emergency call
  • Watches doors and cupboards – a fire exit or drug cupboard, via magnetic contacts
  • Monitoring you can pause – isolation keyswitch, switches monitoring off when ISOLATED
  • Clears calls at the point – Reset button for calls from this unit and devices wired on the same Zone
  • Status at a glance – Red/Green Reassurance LED, lit green when the device is isolated

For installers

  • Power: check the Quantec system's documentation for the load figure before adding it to the network.
  • Mounting: standard UK 25mm single gang flush or surface back box. 87 W x 87 H x 29 D mm, 90g.
  • Cabling: connections are Net +, Net -, R, G, L+ and SW.
  • Compatibility: interfaces devices to Quantec. R and G take an optional slave overdoor light, or G and SW an optional Call Alert Unit.
  • Standards: IP41.

Frequently asked questions

What does a monitoring point do?

It turns a switched event into a call on a Quantec system. It can raise a Standard or Emergency call when a monitored door opens or a telephone or door bell rings.

Can it monitor a PIR?

Yes. It works with PIRs, strip switches, flow switches and other devices with a normally open or normally closed switch.

What happens when it is isolated?

The LED lights green, and the monitored door or device may be opened and closed without signalling a call on the system.

What does the RESET button cancel?

Calls made from the monitoring point and from devices wired on the same Zone.

Does it fit a standard back box?

Yes. It mounts on a standard UK 25mm single gang flush or surface back box.

Is there a magnetic reset version?

Yes. The QT604M is the secure magnetic reset version, which is a different code.

£ 52 56
RRP: £63.07 Save £10.51
Google Top Quality Store · Rated Exceptional
Ships from United Kingdom
28 days hassle free returns
Secure payment transactions
Price
£52.56 Incl. VAT £63.07
Add a WME Product Care Plan Includes warranty, replacement and repairs backed by WME
Why add a product care plan:
  • Full breakdown support
  • Full replacement if we can't repair your product within 10 days
  • All parts, labour and callouts included if necessary
  • Extended manufacturer warranty with faster turn arounds
  • Excludes accidental & cosmetic damages
By selecting one of these plans you agree to purchase WME Care Plan. Please read the Terms and Important information to ensure WME Care Plan is right for you. Compare prices of extended warranties for electrical goods at www.compareextendedwarranties.co.uk
WME Care
Technical Details
Specifications
Brand
C-TEC
Model
QT604
Manufacturer Part Number (MPN)
QT604
Product type
Quantec Monitoring Point, Button Reset
Call types
Standard or Emergency
Monitors
Any device with a normally open or normally closed switch
Indicators
Red/Green Reassurance LED (lit green when device is isolated)
Isolation control
Isolation keyswitch (switches monitoring off when ISOLATED)
Reset control
Reset button (cancels calls made from the monitoring point and from devices wired on the same Zone)
Connections
Net +: Net -; R; G; L+; SW
Expansion, R and G
Optional slave overdoor light
Expansion, G and SW
Optional Call Alert Unit
Onboard 6.35mm Remote Jack Socket
No
Onboard Infrared Receiver
No
Product dimensions
87 W x 87 H x 29 D mm
Mounting
Standard UK 25mm single gang flush or surface back box
Construction and finish
Plastic
IP rating
IP41
Weight
90g
Operating temperature
-5ºC to +40ºC
Max. relative humidity
95% non-condensing
Dimensions
Dimensions
87 W x 87 H x 29 D mm

Specifications

Brand C-TEC
Model QT604
Manufacturer Part Number (MPN) QT604
Product type Quantec Monitoring Point, Button Reset
Call types Standard or Emergency
Monitors Any device with a normally open or normally closed switch
Indicators Red/Green Reassurance LED (lit green when device is isolated)
Isolation control Isolation keyswitch (switches monitoring off when ISOLATED)
Reset control Reset button (cancels calls made from the monitoring point and from devices wired on the same Zone)
Connections Net +: Net -; R; G; L+; SW
Expansion, R and G Optional slave overdoor light
Expansion, G and SW Optional Call Alert Unit
Onboard 6.35mm Remote Jack Socket No
Onboard Infrared Receiver No
Product dimensions 87 W x 87 H x 29 D mm
Mounting Standard UK 25mm single gang flush or surface back box
Construction and finish Plastic
IP rating IP41
Weight 90g
Operating temperature -5ºC to +40ºC
Max. relative humidity 95% non-condensing

Dimensions

Dimensions 87 W x 87 H x 29 D mm

C-TEC QT604 monitoring point, front view

C-TEC Quantec Monitoring Point, Keyswitch Isolation, Button Reset QT604

Overview

A call system usually relies on someone pressing a button. This unit covers the events nobody presses a button for, such as an exit door opening.

It belongs to C-TEC's Quantec range and sits among the wider nurse call systems on this site. It is a plastic plate with a key, a button and one LED on the front.

How it works

  • The trigger: a magnetic contact, a PIR or another switched device changes state, and that change is what the unit watches for.
  • The call level: the unit is configured so the event raises either call level. Check the Quantec system's documentation for how that setting is made.
  • The shared reset: resetting here also clears devices wired on the same Zone, so think about what else shares that Zone before relying on it.

Where to use it

Typical examples are a fire exit, a drug cupboard, a telephone and a door bell. Think of it as a way of bringing something that only has a switch onto the call system.

As a rule, an IP41 rating gives no protection against splashing, so a dry indoor position is the sensible choice.

What the figures mean in practice

  • Humidity limit: the 95% figure is non-condensing, so avoid positions where moisture forms on the plate.
  • Temperature: -5ºC to +40ºC leaves little margin in a very cold lobby or next to a heat source.

Installing it

  • Back box: flush or surface both work, so choose to suit the wall and the cable route, keeping to the 25mm single gang size.
  • The key: as a rule, keep it with whoever is responsible for the system, because it takes this point out of monitoring.
  • Testing: as a rule, open the monitored door and confirm the expected call level appears, then isolate it and repeat.

Planning your system

It needs a Quantec system to report to and a switched device to watch. As a rule, door contacts are a common choice for a door or cupboard, so check the one you pick has a normally open or normally closed output.

There is no onboard 6.35mm remote jack socket and no onboard infrared receiver, so it takes neither a remote lead nor an infrared signal directly.

Confirm the codes for the optional slave overdoor light or Call Alert Unit against the rest of the system.

Standards and ratings explained

  • IP41: the first digit means protection from solid objects over 1 mm, and the second means protection from water drops falling straight down.
C-TEC QT604 monitoring point, front view
C-TEC

C-TEC Quantec Monitoring Point, Keyswitch Isolation, Button Reset QT604

£52.56 £63.07

The C-TEC QT604 is a Quantec monitoring point for nurse call systems. It watches a fire exit, a drug cupboard or any normally open or closed switch, and raises a Standard or Emergency call. An isolation keyswitch switches monitoring off when needed, and a RESET button cancels calls.

Key features

For installers

Frequently asked questions

What does a monitoring point do?

It turns a switched event into a call on a Quantec system. It can raise a Standard or Emergency call when a monitored door opens or a telephone or door bell rings.

Can it monitor a PIR?

Yes. It works with PIRs, strip switches, flow switches and other devices with a normally open or normally closed switch.

What happens when it is isolated?

The LED lights green, and the monitored door or device may be opened and closed without signalling a call on the system.

What does the RESET button cancel?

Calls made from the monitoring point and from devices wired on the same Zone.

Does it fit a standard back box?

Yes. It mounts on a standard UK 25mm single gang flush or surface back box.

Is there a magnetic reset version?

Yes. The QT604M is the secure magnetic reset version, which is a different code.

View product