Hochiki I.S. Compatible Dual Zone Monitor, ESP, Isolator CHQ-DZM(SCI)-IS
About this product
The Hochiki CHQ-DZM(SCI)-IS is a dual zone monitor that links conventional intrinsically safe detectors to a Hochiki ESP addressable loop. It suits sites where part of the building is a hazardous area needing I.S. detection. It takes up to 40 I.S. detectors over two zones, through an appropriate barrier, and has a built-in isolator.
Key features
- Brings hazardous areas onto an addressable system – up to 40 (20 per zone) conventional I.S. detectors
- Two independent zones – both fully monitored for short/open circuit
- Call points too – up to 20 CCP-E-IS manual call points per zone
- One loop address – set with DIL switches
- Contains loop faults – integral short-circuit isolator
- Clear status – green LED flashes when polled, amber LED lights on a short-circuit fault
- Approved – EN54-17 and EN54-18
For installers
- Power: loop 17 – 41 VDC, 330 µA quiescent, 22 mA ± 20 % whilst polling. Auxiliary 24 VDC supply required: 20-28.8 VDC, 70 mA with both zones in fire.
- Mounting: safe area only, with the barrier. Smart-Fix module 127 x 157 x 35 mm; can be fitted within an IP67 rated enclosure.
- Cabling: zone resistance 50 Ω (Max), zone capacitance 0.3 µF (Max), 10 kΩ end-of-line resistor supplied. Wire call points at the beginning of the zone.
- Compatibility: Hochiki ESP; SLR-E-IS and DCD-1E-IS detectors, CCP-E-IS call points. Barriers: KFD0-CS-Ex1.51P, KFD0-CS-Ex2.51P, MTL5061 & MTL4061, MTL7728+, MTL728+, P&F Z728. Fire alarm control panel compatibility required.
- Standards: EN54-17 short circuit isolators, EN54-18 input/output modules.
In the box
- "Smart-Fix" CHQ module (back plate including PCB)
- CHQ-LID transparent module lid with four screws and retaining washers
- 10 kΩ end-of-line resistor
Frequently asked questions
Can the module go inside the hazardous area?
No. It must be installed in the safe area, along with the barrier.
Which detectors can it monitor?
Hochiki conventional I.S. CDX Range detectors: up to 20 SLR-E-IS or DCD-1E-IS per zone, or a mixture of both.
Does it need a barrier?
Yes. An appropriate barrier must be used, such as the KFD0-CS-Ex1.51P galvanic isolator or the MTL7728+ zener barrier.
Does it need a separate power supply?
Yes. Besides the loop, it requires an auxiliary 24 VDC supply, 20-28.8 VDC.
Where do call points go on the zone?
At the beginning of the zone. The zones do not support any line continuity options.
Which panels does it work with?
Hochiki ESP analogue addressable panels. Check the panel's documentation that it supports this module.
Specifications
Dimensions
Specifications
| Brand | Hochiki |
|---|---|
| Model | CHQ-DZM(SCI)-IS |
| Manufacturer Part Number (MPN) | CHQ-DZM(SCI)-IS |
| Product type | Intrinsically safe compatible dual zone monitor, Smart-Fix module |
| Order codes | CHQ-DZM(SCI)-IS (module); DIN version CHQ-DZM/DIN(SCI)-IS |
| Transmission method | Digital communication using ESP |
| Loop operating voltage | 17 – 41 VDC |
| Loop quiescent current | 330 µA |
| Current consumption whilst polling | 22 mA ± 20 % |
| Isolator leakage current (switch open) | 8 mA (max) |
| Isolator switch current (switch closed) | 1 A (max) |
| External supply operating voltage | 20-28.8 VDC (24 VDC nominal) |
| External current consumption when in fire | 70 mA (both zones in fire) |
| Output rating | 24 VDC 8.5 mA |
| Zone loading (max) | Up to 20 SLR-E-IS or DCD-1E-IS detectors (or a mixture of both); up to 20 CCP-E-IS manual call points |
| E.O.L device | 10 kΩ resistor (supplied with unit) |
| Zone resistance | 50 Ω (Max) |
| Zone capacitance | 0.3 µF (Max) |
| Outputs | Two controllable outputs for remote LEDs (if supported by the control panel) |
| Compatible barrier types | Galvanic isolators KFD0-CS-Ex1.51P, KFD0-CS-Ex2.51P, MTL5061 & MTL4061 (older types); zener barriers MTL7728+, MTL728+ (older type), P&F Z728 |
| Operating temperature range | -10 °C to +50 °C |
| Storage temperature range | -30 °C to +60 °C |
| Dimensions (module) | 127 x 157 x 35 mm |
| Certification | EN54-17 short circuit isolators; EN54-18 input/output modules; 0832-CPD-1659 |
Dimensions
| Dimensions | 127 x 157 x 35 mm |
|---|
Hochiki I.S. Compatible Dual Zone Monitor, ESP, Isolator CHQ-DZM(SCI)-IS