Vanderbilt ACTpro-1520 Door Controller, Single Door IP, 12V 2A PSU V54502-C110-A100

Free Delivery
£ 428 86
(Incl. VAT) RRP: £514.63
Save £85.77

About this product

The Vanderbilt V54502-C110-A100 (ACTpro-1520) is a door controller for one access controlled door, with its own 2Amp 12V DC PSU. It takes a 230VAC mains input and suits installers building a single door system or a larger one. It supports 60,000 users and connects over Ethernet.

Key features

  • Powers the door from one box – built-in 2Amp 12V DC PSU with battery charging
  • Room for a large user list – 60,000 users, each with 4 credentials and one PIN code
  • Can grow with the site – systems that need to grow up to 4,000 doors
  • Network ready – 2 Ethernet ports, with DHCP or static IP addressing
  • Works with fire alarm wiring – fire alarm override, and unlock configured doors on fire input
  • Flags faults – tamper, mains and break glass monitoring, reported in ACT Enterprise software
  • Handles wireless locks too – 16 Aperio locks supported per controller

For installers

  • Power: 230VAC +/- 10% mains input. PSU output 13.65V (+/-5%), 1.5A @ 25°C plus 0.5A for battery charging. Standby battery type: 12V 7AHr Battery.
  • Mounting: surface mounting, Internal Use only. 236 x 255 x 84 mm, net weight 0.975 kg.
  • Cabling: inputs for Door Contact(DC), Push Button (PB/REX), AC Monitoring, Emergency Door Release (BG/EDR) and Tamper. Relay limits with inductive loads are 1.5A @ 30VDC or 1.5A @ 50VAC on the main relay.
  • Compatibility: compatible with all ACT readers, Vanderbilt and HID OSDP readers, and 3rd Party Wiegand and C&D readers.
  • Standards: Directive 2014/30/EU, Directive 2014/35/EU and Directive 2011/65/EU.

Frequently asked questions

What is a door controller?

It is the unit that decides whether a credential opens the door, then switches the lock. This one is a single door IP controller with 2Amp 12V DC PSU.

Does it have a power supply built in?

Yes. The ACTpro-1520 includes a 2Amp 12V DC PSU, fed from 230VAC +/- 10%.

Can it power a maglock directly?

Check the load first. The PSU is rated at 1.5A @ 25°C plus 0.5A for battery charging, and the main relay at 1.5A @ 30VDC or 1.5A @ 50VAC with maglock or strike loads.

What standby battery does it use?

A 12V 7AHr Battery.

Does it work with non-Vanderbilt readers?

Usually yes, if the reader uses a supported format. It takes HID OSDP readers and 3rd Party Wiegand and C&D readers, so check any other reader against those formats.

Can it be fitted outside?

No. It is for surface mounting, Internal Use only.

£ 428 86
RRP: £514.63 Save £85.77
Google Top Quality Store · Rated Exceptional
Ships from United Kingdom
28 days hassle free returns
Secure payment transactions
Price
£428.86 Incl. VAT £514.63
Add a WME Product Care Plan Includes warranty, replacement and repairs backed by WME
Why add a product care plan:
  • Full breakdown support
  • Full replacement if we can't repair your product within 10 days
  • All parts, labour and callouts included if necessary
  • Extended manufacturer warranty with faster turn arounds
  • Excludes accidental & cosmetic damages
By selecting one of these plans you agree to purchase WME Care Plan. Please read the Terms and Important information to ensure WME Care Plan is right for you. Compare prices of extended warranties for electrical goods at www.compareextendedwarranties.co.uk
WME Care
Technical Details
Specifications
Brand
Vanderbilt
Model
V54502-C110-A100
Manufacturer Part Number (MPN)
V54502-C110-A100
Also listed as
ACTpro-1520
Product type
ACTpro-1520, single door IP controller with 2Amp 12V DC PSU
Controller input voltage
9-28V DC
Controller current consumption
350mA (Max)
Operating environment
Surface mounting, Internal Use only
Environmental temperature
-10 to +55° C
Gross product weight
1.14 kg
Net product weight
0.975 kg
Size (W x L x D)
236 x 255 x 84 mm
Enclosure material
ABS, Gray
LED status indicators
Yes
PSU fault output
No
Lid opening tamper detection (front)
Yes
Rear tamper detection
No
MTBF
200,000 hr
Mains input
230VAC +/- 10%
Mains frequency
47-53Hz
Mains input fuse
625mA 250V anti-surge fuse
PSU output voltage
13.65V (+/-5%)
PSU max load current
1.5A @ 25°C plus 0.5A for battery charging
Load output fuse
2A PTC Resettable Fuse
Battery charging
Yes
Standby battery
12V 7AHr Battery
Battery protections
Deep Discharge/Over Charge/Reverse Polarity
Battery current
~0.5A for a battery discharged to ~10V
AC mains monitoring
Yes
Users
60,000
Credentials per user
4 credentials and one PIN code per user
User groups
2,000 (firmware version 1.08 or later required)
Doors on controller
1
Log events
20,000
System growth
Up to 4,000 doors
Ethernet ports
2, maximum of 4 controllers on hub network
IP addressing
DHCP/Static IP address
Door relay output
5 Amp
Auxiliary relay output
1 Amp
Main relay with inductive load
1.5A @ 30VDC or 1.5A @ 50VAC
Aux relay with inductive load
400mA @ 30VDC
Inputs
Door Contact(DC), Push Button (PB/REX), AC Monitoring, Emergency Door Release (BG/EDR), Tamper
Programmable input
AUXI (Interlock, Fire override, Alarm monitoring), 1
Programmable outputs
OP2, OP3, 2 (100mA)
Entry and exit readers
Yes (multiple up to 500mA)
ACT readers
Compatible with all ACT readers
OSDP readers
Vanderbilt and HID OSDP readers
OSDP security
Secure communications using 128bit AES encryption
Third party readers
3rd Party Wiegand and C&D Readers
Bluetooth credentials
Bluetooth mobile credential support via OSDP or Wiegand bluetooth readers
Door station support
ACT Door Station support (RS485), Yes (31 Door Stations)
Door stations per controller
Up to 32 doors per Controller
Wireless locks per controller
Aperio Locks supported per controller, 16
Wireless lock versions
ASSA Aperio Wireless locks Version 2 and Version 3 locks
Fire alarm override
Yes
Unlock configured doors on fire input
Yes
Airlock/Interlock
Yes
Anti-passback
Local and Global Anti-passback (controllers must be on the same routable network)
EDR monitoring
Emergency Door Release(EDR)/break glass Monitoring or Deadbolt monitoring (FW 1.09.06 or later required)
Elevator control
Elevator Control with ACTpro-IOM (maximum 96 floors)
Arm/Disarm intruder panel
Yes
PIN lockout
Automatic user lockout for 5 minutes after 5 failed PIN code attempts (Card and PIN mode)
EMC directive
Directive 2014/30/EU (Electromagnetic Compatibility Directive)
Low Voltage directive
Directive 2014/35/EU (Low Voltage Directive)
RoHS directive
Directive 2011/65/EU
Dimensions
Dimensions
236 x 255 x 84 mm (W x L x D)

Specifications

Brand Vanderbilt
Model V54502-C110-A100
Manufacturer Part Number (MPN) V54502-C110-A100
Also listed as ACTpro-1520
Product type ACTpro-1520, single door IP controller with 2Amp 12V DC PSU
Controller input voltage 9-28V DC
Controller current consumption 350mA (Max)
Operating environment Surface mounting, Internal Use only
Environmental temperature -10 to +55° C
Gross product weight 1.14 kg
Net product weight 0.975 kg
Size (W x L x D) 236 x 255 x 84 mm
Enclosure material ABS, Gray
LED status indicators Yes
PSU fault output No
Lid opening tamper detection (front) Yes
Rear tamper detection No
MTBF 200,000 hr
Mains input 230VAC +/- 10%
Mains frequency 47-53Hz
Mains input fuse 625mA 250V anti-surge fuse
PSU output voltage 13.65V (+/-5%)
PSU max load current 1.5A @ 25°C plus 0.5A for battery charging
Load output fuse 2A PTC Resettable Fuse
Battery charging Yes
Standby battery 12V 7AHr Battery
Battery protections Deep Discharge/Over Charge/Reverse Polarity
Battery current ~0.5A for a battery discharged to ~10V
AC mains monitoring Yes
Users 60,000
Credentials per user 4 credentials and one PIN code per user
User groups 2,000 (firmware version 1.08 or later required)
Doors on controller 1
Log events 20,000
System growth Up to 4,000 doors
Ethernet ports 2, maximum of 4 controllers on hub network
IP addressing DHCP/Static IP address
Door relay output 5 Amp
Auxiliary relay output 1 Amp
Main relay with inductive load 1.5A @ 30VDC or 1.5A @ 50VAC
Aux relay with inductive load 400mA @ 30VDC
Inputs Door Contact(DC), Push Button (PB/REX), AC Monitoring, Emergency Door Release (BG/EDR), Tamper
Programmable input AUXI (Interlock, Fire override, Alarm monitoring), 1
Programmable outputs OP2, OP3, 2 (100mA)
Entry and exit readers Yes (multiple up to 500mA)
ACT readers Compatible with all ACT readers
OSDP readers Vanderbilt and HID OSDP readers
OSDP security Secure communications using 128bit AES encryption
Third party readers 3rd Party Wiegand and C&D Readers
Bluetooth credentials Bluetooth mobile credential support via OSDP or Wiegand bluetooth readers
Door station support ACT Door Station support (RS485), Yes (31 Door Stations)
Door stations per controller Up to 32 doors per Controller
Wireless locks per controller Aperio Locks supported per controller, 16
Wireless lock versions ASSA Aperio Wireless locks Version 2 and Version 3 locks
Fire alarm override Yes
Unlock configured doors on fire input Yes
Airlock/Interlock Yes
Anti-passback Local and Global Anti-passback (controllers must be on the same routable network)
EDR monitoring Emergency Door Release(EDR)/break glass Monitoring or Deadbolt monitoring (FW 1.09.06 or later required)
Elevator control Elevator Control with ACTpro-IOM (maximum 96 floors)
Arm/Disarm intruder panel Yes
PIN lockout Automatic user lockout for 5 minutes after 5 failed PIN code attempts (Card and PIN mode)
EMC directive Directive 2014/30/EU (Electromagnetic Compatibility Directive)
Low Voltage directive Directive 2014/35/EU (Low Voltage Directive)
RoHS directive Directive 2011/65/EU

Dimensions

Dimensions 236 x 255 x 84 mm (W x L x D)

Vanderbilt V54502-C110-A100 door controller, front view

Vanderbilt ACTpro-1520 Door Controller, Single Door IP, 12V 2A PSU V54502-C110-A100

What this controller is for

Every access controlled door needs a decision point. It reads the credential, checks the user's rights and switches the lock.

This Vanderbilt unit is that decision point for one door, in a box that also holds the power supply. It suits a single door today or a site that plans to add more doors later.

How it works

  • IP controller: it connects over a data network, using DHCP or a static IP address, instead of a dedicated control cable.
  • Dual port switch: the 2 Ethernet ports let controllers pass the network along, with a maximum of 4 controllers on a hub network.
  • Credentials: each user can hold 4 credentials and one PIN code, with card only, PIN only and card and PIN operation.
  • OSDP: a reader connection standard. It offers secure communications using 128bit AES encryption with Vanderbilt OSDP readers.

Where to use it

It is an internal, surface mounted unit rated for -10 to +55° C, so plan a dry location such as a comms cupboard or a ceiling void with access.

On an escape route, the fire alarm override and fire input are wiring options, not a design. As a rule, how the door releases should be settled with whoever holds the building's fire strategy.

What the figures mean in practice

  • 1.5A @ 25°C plus 0.5A for battery charging: this is how the 2Amp PSU divides up. Add the lock, the readers and any other load together, and keep the total inside the 1.5A figure.
  • 5 Amp and 1.5A relay figures: the door relay is rated 5 Amp, but with inductive loads such as a maglock or strike the main relay figure is 1.5A @ 30VDC or 1.5A @ 50VAC. Use the lower figure for a lock.
  • 20,000 log events: this is how many events the controller can hold in its log.
  • Automatic lockout: in Card and PIN mode, 5 failed PIN code attempts lock the user out for 5 minutes.

Installing it

  • Space: allow for 236 x 255 x 84 mm on the wall, and use the space in the enclosure for cable management.
  • Tamper: it has lid opening tamper detection at the front, but no rear tamper detection, so choose the position with that in mind.
  • Firmware: 2,000 user groups need firmware version 1.08 or later, and EDR or deadbolt monitoring needs FW 1.09.06 or later. Check the version on site before relying on those functions.
  • Readers: entry and exit readers are supported, multiple up to 500mA in total, so add up reader current before wiring.

Planning your system

The controller is one part of the door. The job also needs a lock, such as maglocks or electric strikes, a reader, an exit device and usually a standby battery.

  • Readers: the controller is compatible with all ACT readers. Check the reader's own data and the credential type before ordering.
  • Adding a door: use the ACTpro-120 door station with 2Amp 12V DC PSU for extending a system over RS485.
  • Software: extra rights and door plans require ACT Enterprise pro, so check which functions the site needs. The access control system guide covers how the wider system fits together.

Standards explained

The three directives for this model cover electromagnetic compatibility, low voltage safety and restricted hazardous substances. They are the basis of its CE marking.

Vanderbilt's other controllers and readers are grouped under Vanderbilt products, and other makes are under access controllers and panels.

Vanderbilt V54502-C110-A100 door controller, front view
Vanderbilt

Vanderbilt ACTpro-1520 Door Controller, Single Door IP, 12V 2A PSU V54502-C110-A100

£428.86 £514.63

The Vanderbilt V54502-C110-A100 (ACTpro-1520) is a door controller for one access controlled door, with its own 2Amp 12V DC PSU. It takes a 230VAC mains input and suits installers building a single door system or a larger one. It supports 60,000 users and connects over Ethernet.

Key features

For installers

Frequently asked questions

What is a door controller?

It is the unit that decides whether a credential opens the door, then switches the lock. This one is a single door IP controller with 2Amp 12V DC PSU.

Does it have a power supply built in?

Yes. The ACTpro-1520 includes a 2Amp 12V DC PSU, fed from 230VAC +/- 10%.

Can it power a maglock directly?

Check the load first. The PSU is rated at 1.5A @ 25°C plus 0.5A for battery charging, and the main relay at 1.5A @ 30VDC or 1.5A @ 50VAC with maglock or strike loads.

What standby battery does it use?

A 12V 7AHr Battery.

Does it work with non-Vanderbilt readers?

Usually yes, if the reader uses a supported format. It takes HID OSDP readers and 3rd Party Wiegand and C&D readers, so check any other reader against those formats.

Can it be fitted outside?

No. It is for surface mounting, Internal Use only.