Shaver Sockets and Bathroom Power: What's Actually Allowed (2026)
A shaver socket is the only socket normally allowed in a UK bathroom, because of the isolating transformer inside it. Zones, the 20VA limit and the 3m exception.
Jujhar Bhambra |
Get help with all your electrical products from WME.
A shaver socket is the only socket normally allowed in a UK bathroom, because of the isolating transformer inside it. Zones, the 20VA limit and the 3m exception.
Jujhar Bhambra |
Space downlights at roughly half your ceiling height apart. Fire rating, IP zones, GU10 vs integrated, and why twelve fittings is not twice as good as six.
Jujhar Bhambra |
A cooker switch is a 45A double-pole isolator on its own circuit. With or without socket, where it goes, and the cable question to ask before you buy.
Jujhar Bhambra |
Size a PoE switch on its power budget, not its port count. PoE vs PoE+ vs Hi-PoE, the 100m cable limit, and switch vs injector.
Jujhar Bhambra |
The amps on a USB socket are shared across the ports, not per port. Socket-with-USB vs USB-only, back box depth, and where they earn their keep.
Jujhar Bhambra |
A fused spur puts one appliance on its own fuse. Switched vs unswitched, the flex outlet people forget to specify, and where the regs need one.
Jujhar Bhambra |
VESA and weight rating decide your TV bracket, not screen inches. Fixed vs tilting vs full-motion, and the wall type that changes your fixings.
Jujhar Bhambra |
Why there are nine wires in your ceiling rose, what each terminal bank does, which conductor stays live with the switch off, and when the job stops being DIY.
Jujhar Bhambra |
24V or 230V, why one needs a driver and one doesn't, how to size it with proper headroom, linking and cutting, and the IP rating that decides where strip lighting...
Jujhar Bhambra |
Sizing an extractor fan in litres per second, IP zones, timer vs humidistat, the ducting rules everyone breaks, and the triple-pole isolator most quotes leave off.
Jujhar Bhambra |
UK emergency lighting regulations explained — where it's required, the 3-hour rule, maintained vs non-maintained, BS 5266 testing and who carries the duty. A clear guide from WME, Birmingham, est....
Jujhar Bhambra |
Dimmer switch wiring made simple — one-way and two-way explained, leading vs trailing edge, and the LED mistake that makes lights flicker. A UK guide from WME, Birmingham, est. 1975.
Jujhar Bhambra |
Where to fit a carbon monoxide detector — the right height, the distance from your boiler, which rooms actually need one and the mistakes we see every week. A clear...
Jujhar Bhambra |