C-TEC CAST-PRO Smoke and Heat Multisensor with Tone Sounder, 92dB(A), Addressable CP414T

£ 69 22
(Incl. VAT) RRP: £83.06
Save £13.84

About this product

The C-TEC CP414T is a CAST-PRO smoke and heat multisensor with a built-in tone sounder, for C-TEC's ZFP CAST protocol addressable fire panels. One device detects fire and sounds the alarm at 92dB(A). It suits sites that want fewer devices on the ceiling and fewer false alarms.

Key features

  • Detects and warns in one device – smoke and heat multisensor plus a 92dB(A) tone alarm sounder
  • Fewer false alarms – MASC™ chamber and AFFIRM™ algorithms tolerate false alarm sources
  • Settings for the day and night – 8 detection modes, default Mode 7
  • Stays accurate as it ages – drift compensation
  • Protects the loop – onboard short circuit loop isolator
  • Easy to spot in alarm – 2 red LED indicator strips with 360º visibility

For installers

  • Power: 28 to 40V DC loop supply, 2-wire, polarity sensitive. Quiescent 590uA @ 40V; alarm 5.4mA max (Imax at Vmin).
  • Mounting: requires a CA408 CAST base, or the CA408R relay base. 105mm diameter x 65mm deep in base, 176g.
  • Cabling: via the CA408 base, terminal 1 +Ve IN, 2 +Ve OUT, 3 Remote LED.
  • Compatibility: C-TEC's ZFP CAST addressable fire alarm systems.
  • Standards: KIWA certified to EN54-3, 5, 7, 17 & 29. CPR number 0063-CPR-242190019. IP21C.

Frequently asked questions

Does it need a separate base?

Yes. It requires a CA408 CAST base, or the CA408R relay base where a relay is wanted.

Which panels does it work with?

C-TEC's ZFP CAST protocol addressable fire panels. It uses the CAST protocol, so it is not for other makers' panels.

How loud is the sounder?

92dB(A) at 1m, measured as LAFmax at Vmax.

Does it have a flashing beacon?

No. It has a tone sounder only, and VAD category and coverage is N/A. Its red LED strips show alarm status, not a visual alarm signal.

Can it be used in a damp room?

It is rated IP21C and takes up to 95% humidity, non-condensing, so it is for normal indoor areas.

£ 69 22
RRP: £83.06 Save £13.84
Google Top Quality Store · Rated Exceptional
Ships from United Kingdom
28 days hassle free returns
Secure payment transactions
Price
£69.22 Incl. VAT £83.06
Add a WME Product Care Plan Includes warranty, replacement and repairs backed by WME
Why add a product care plan:
  • Full breakdown support
  • Full replacement if we can't repair your product within 10 days
  • All parts, labour and callouts included if necessary
  • Extended manufacturer warranty with faster turn arounds
  • Excludes accidental & cosmetic damages
By selecting one of these plans you agree to purchase WME Care Plan. Please read the Terms and Important information to ensure WME Care Plan is right for you. Compare prices of extended warranties for electrical goods at www.compareextendedwarranties.co.uk
WME Care
Technical Details
Specifications
Brand
C-TEC
Model
CP414T
Manufacturer Part Number (MPN)
CP414T
Product type
CAST-PRO Smoke + Heat Multisensor c/w Tone Sounder
Type
Heat & Smoke Fire Detection plus Tone Alarm
Protocol
C-TEC CAST
Compatible panels
C-TEC ZFP CAST Addressable Fire Alarm Systems
Sensitivity
8 Detection Modes (default Mode 7)
Sound pressure level
92dB(A) (LAFmax at Vmax at 1m)
VAD category & coverage
N/A
Supply voltage
28 to 40V DC
Supply wiring
2-wire, polarity sensitive
Quiescent current
590uA @ 40V
Alarm current (Imax at Vmin)
5.4mA (max volume)
Alarm current (Iavg at Vmin)
5.0mA (max volume)
Indicators
2 red LED indicator strips, 8mm x 2mm, 360º visibility
Loop isolator
Onboard short circuit loop isolator
Base
Requires CA408 CAST base, or CA408R relay base
Dimensions
105mm diameter x 48mm deep (detector only); 105mm diameter x 65mm deep (in base)
Weight
122g (not in base); 176g (in base)
IP rating
IP21C
Humidity
Max 95% relative humidity (non-condensing)
Approvals
KIWA certified to EN54-3, 5, 7, 17 & 29
CPR number
0063-CPR-242190019
Dimensions
Dimensions
105mm diameter x 48mm deep (detector only); 105mm diameter x 65mm deep (in base)

Specifications

Brand C-TEC
Model CP414T
Manufacturer Part Number (MPN) CP414T
Product type CAST-PRO Smoke + Heat Multisensor c/w Tone Sounder
Type Heat & Smoke Fire Detection plus Tone Alarm
Protocol C-TEC CAST
Compatible panels C-TEC ZFP CAST Addressable Fire Alarm Systems
Sensitivity 8 Detection Modes (default Mode 7)
Sound pressure level 92dB(A) (LAFmax at Vmax at 1m)
VAD category & coverage N/A
Supply voltage 28 to 40V DC
Supply wiring 2-wire, polarity sensitive
Quiescent current 590uA @ 40V
Alarm current (Imax at Vmin) 5.4mA (max volume)
Alarm current (Iavg at Vmin) 5.0mA (max volume)
Indicators 2 red LED indicator strips, 8mm x 2mm, 360º visibility
Loop isolator Onboard short circuit loop isolator
Base Requires CA408 CAST base, or CA408R relay base
Dimensions 105mm diameter x 48mm deep (detector only); 105mm diameter x 65mm deep (in base)
Weight 122g (not in base); 176g (in base)
IP rating IP21C
Humidity Max 95% relative humidity (non-condensing)
Approvals KIWA certified to EN54-3, 5, 7, 17 & 29
CPR number 0063-CPR-242190019

Dimensions

Dimensions 105mm diameter x 48mm deep (detector only); 105mm diameter x 65mm deep (in base)

C-TEC CP414T smoke and heat multisensor with tone sounder, angled view

C-TEC CAST-PRO Smoke and Heat Multisensor with Tone Sounder, 92dB(A), Addressable CP414T

Overview

A combined detector and sounder saves a second device and a second fixing on the ceiling. This C-TEC unit detects smoke and heat and gives its own tone alarm.

It is built for one family of panels only, so it suits sites already running, or planning, a C-TEC CAST system.

How it works

  • Multisensor: a detector that reads more than one sign of fire. This one combines smoke and heat, which helps it confirm a real fire.
  • MASC™ and AFFIRM™: MASC™ stands for Miniature Advanced Smoke Detection Chamber. With the AFFIRM™ algorithms it is designed to tolerate false alarms while still detecting real fires.
  • Detection modes: there are 8 detection modes, with Mode 7 as the default. Different sensitivities can be used for different times of the day.
  • Loop isolator: a short circuit on one part of an addressable loop is cut off by the isolator, so the rest of the loop keeps working.

Where to use it

It suits ordinary indoor rooms and corridors where a fire alarm sounder is needed close to the detector. The rating is IP21C.

In most buildings, areas with steam, heavy dust or outdoor exposure need a different device.

What the figures mean in practice

  • 92dB(A) at 1m: the sound level measured close to the device. It falls with distance, so sounder coverage is planned room by room.
  • 5.4mA in alarm: the current at maximum volume. Loop and battery calculations should use this figure, not the 590uA quiescent current.
  • 65mm deep in base: the total depth below the ceiling once the head sits in its CA408 base.

Installing it

Fit the CA408 CAST base first and wire the loop through it, keeping polarity correct. Where something else must switch on alarm, the CA408R relay base can be used instead.

Terminal 3 on the base serves a remote LED, which helps where the detector sits out of sight.

Planning your system

Each CP414T needs a base and a ZFP CAST panel to report to.

Other C-TEC heads are in the C-TEC detector range, and more choices sit in the wider fire detectors section.

The guide to commercial fire alarm systems explains why a loop device must match the panel protocol.

Standards and ratings explained

  • EN54-3, 5, 7, 17 & 29: parts of the EN54 series covering sounders, heat detectors, smoke detectors, short circuit isolators and multi-sensor detectors. This device is KIWA certified to all five.
  • CPR number: the Construction Products Regulation reference for the certification, 0063-CPR-242190019.
  • IP21C: basic protection against fingers and vertically dripping water, which suits indoor use.
C-TEC CP414T smoke and heat multisensor with tone sounder, angled view
C-TEC

C-TEC CAST-PRO Smoke and Heat Multisensor with Tone Sounder, 92dB(A), Addressable CP414T

£69.22 £83.06

The C-TEC CP414T is a CAST-PRO smoke and heat multisensor with a built-in tone sounder, for C-TEC's ZFP CAST protocol addressable fire panels. One device detects fire and sounds the alarm at 92dB(A). It suits sites that want fewer devices on the ceiling and fewer false alarms.

Key features

For installers

Frequently asked questions

Does it need a separate base?

Yes. It requires a CA408 CAST base, or the CA408R relay base where a relay is wanted.

Which panels does it work with?

C-TEC's ZFP CAST protocol addressable fire panels. It uses the CAST protocol, so it is not for other makers' panels.

How loud is the sounder?

92dB(A) at 1m, measured as LAFmax at Vmax.

Does it have a flashing beacon?

No. It has a tone sounder only, and VAD category and coverage is N/A. Its red LED strips show alarm status, not a visual alarm signal.

Can it be used in a damp room?

It is rated IP21C and takes up to 95% humidity, non-condensing, so it is for normal indoor areas.

View product