Vanderbilt ACTpro-1500PoE Access Controller, Single Door IP, PoE++ PSU V54502-C112-A100

Free Delivery
£ 536 24
(Incl. VAT) RRP: £643.49
Save £107.25

About this product

The Vanderbilt V54502-C112-A100 (ACTpro-1500PoE) is an access controller for one door, powered through its PoE++ PSU rather than mains. It suits installers who already run network cable to the door location. It supports 60,000 users, has 2 Ethernet ports and sits in a steel enclosure.

Key features

  • One network cable can power the door – PoE 802.3bt gives 13.8V at 3A output + 0.5A battery charge
  • Room for a large user list – 60,000 users, each with 4 credentials and one PIN code
  • Can grow with the site – systems that need to grow up to 4,000 doors
  • Network ready – 2 Ethernet ports, with DHCP or static IP addressing
  • Works with fire alarm wiring – fire alarm override, and unlock configured doors on fire input
  • Flags faults – front and rear tamper detection, plus a PSU fault output
  • Handles wireless locks too – 16 Aperio locks supported per controller

For installers

  • Power: PoE input. 802.3bt gives 13.8V at 3A output and 802.3at gives 13.8V at 1A output, each + 0.5A battery charge. Standby battery: 12V 7AHr Battery.
  • Mounting: surface mounting, Internal Use only. 355 x 305 x 95 mm, net weight 2.84 kg.
  • Cabling: inputs for Door Contact(DC), Push Button (PB/REX), AC Monitoring, Emergency Door Release (BG/EDR) and Tamper. Relay limits with inductive loads are 1.5A @ 30VDC or 1.5A @ 50VAC on the main relay.
  • Compatibility: compatible with all ACT readers, Vanderbilt and HID OSDP readers, and 3rd Party Wiegand and C&D readers.
  • Standards: Directive 2014/30/EU and Directive 2011/65/EU. RoHS, Reach and WEEE: Yes.

Frequently asked questions

What does an access controller do?

It decides whether a credential opens the door, then switches the lock. This one is a single door IP controller with PoE++ PSU.

Does it need a mains supply?

No. Its power comes from the PoE input, through the PSU in the enclosure.

Can an ordinary PoE switch power it?

It depends on the load. A PoE 802.3at input gives 13.8V at 1A output, while 802.3bt gives 13.8V at 3A output, so match the switch to the lock and readers. Check with Vanderbilt before relying on a plain 802.3af port.

Is a battery included?

Check before ordering, and allow for one if you need standby. The standby battery is a 12V 7AHr Battery, and battery charging is supported.

Does it work with non-Vanderbilt readers?

Usually yes, if the reader uses a supported format. It takes HID OSDP readers and 3rd Party Wiegand and C&D readers.

Can it be fitted outside?

No. It is for surface mounting, Internal Use only.

£ 536 24
RRP: £643.49 Save £107.25
Google Top Quality Store · Rated Exceptional
Ships from United Kingdom
28 days hassle free returns
Secure payment transactions
Price
£536.24 Incl. VAT £643.49
Add a WME Product Care Plan Includes warranty, replacement and repairs backed by WME
Why add a product care plan:
  • Full breakdown support
  • Full replacement if we can't repair your product within 10 days
  • All parts, labour and callouts included if necessary
  • Extended manufacturer warranty with faster turn arounds
  • Excludes accidental & cosmetic damages
By selecting one of these plans you agree to purchase WME Care Plan. Please read the Terms and Important information to ensure WME Care Plan is right for you. Compare prices of extended warranties for electrical goods at www.compareextendedwarranties.co.uk
WME Care
Technical Details
Specifications
Brand
Vanderbilt
Model
V54502-C112-A100
Manufacturer Part Number (MPN)
V54502-C112-A100
Also listed as
ACTpro-1500PoE
Product type
ACTpro-1500PoE, single door IP controller with PoE++ PSU
Controller input voltage
9-28V DC
Controller current consumption
350mA (Max)
Operating environment
Surface mounting, Internal Use only
Environmental temperature
-10 to +40 (operating) 75% RH non-condensing
Gross product weight
3.06 kg
Net product weight
2.84 kg
Size (W x L x D)
355 x 305 x 95 mm
Enclosure material
1.2 mm steel gray powder coated
LED status indicators
Yes
PSU fault output
Yes
Lid opening tamper detection (front)
Yes
Rear tamper detection
Yes
MTBF
50,000 hr
PoE 802.3bt input (PoE Ultra / PoE++)
13.8V at 3A output + 0.5A battery charge
PoE 802.3at input (PoE+)
13.8V at 1A output + 0.5A battery charge
Battery charging
Yes
Standby battery
12V 7AHr Battery
PSU output voltage
13.8V
Users
60,000
Credentials per user
4 credentials and one PIN code per user
User groups
2,000 (firmware version 1.08 or later required)
Doors on controller
1
Log events
20,000
Ethernet ports
2, maximum of 4 controllers on hub network
IP addressing
DHCP/Static IP address
Door relay output
5 Amp
Auxiliary relay output
1 Amp
Main relay with inductive load
1.5A @ 30VDC or 1.5A @ 50VAC
Aux relay with inductive load
400mA @ 30VDC
Inputs
Door Contact(DC), Push Button (PB/REX), AC Monitoring, Emergency Door Release (BG/EDR), Tamper
Programmable input
AUXI (Interlock, Fire override, Alarm monitoring), 1
Programmable outputs
OP2, OP3, 2 (100mA)
Entry and exit readers
Yes (multiple up to 500mA)
Aperio locks supported per controller
16
ACT door station support (RS485)
Yes (31 Door Stations)
Fire alarm override
Yes
Unlock configured doors on fire input
Yes
Local and global anti-passback
Yes, controllers must be on the same routable network
Airlock/Interlock
Yes
Arm/Disarm intruder panel
Yes
PIN lockout
Automatic user lockout for 5 minutes after 5 failed PIN code attempts (Card and PIN mode)
Dimensions
Dimensions
355 x 305 x 95 mm (W x L x D)

Specifications

Brand Vanderbilt
Model V54502-C112-A100
Manufacturer Part Number (MPN) V54502-C112-A100
Also listed as ACTpro-1500PoE
Product type ACTpro-1500PoE, single door IP controller with PoE++ PSU
Controller input voltage 9-28V DC
Controller current consumption 350mA (Max)
Operating environment Surface mounting, Internal Use only
Environmental temperature -10 to +40 (operating) 75% RH non-condensing
Gross product weight 3.06 kg
Net product weight 2.84 kg
Size (W x L x D) 355 x 305 x 95 mm
Enclosure material 1.2 mm steel gray powder coated
LED status indicators Yes
PSU fault output Yes
Lid opening tamper detection (front) Yes
Rear tamper detection Yes
MTBF 50,000 hr
PoE 802.3bt input (PoE Ultra / PoE++) 13.8V at 3A output + 0.5A battery charge
PoE 802.3at input (PoE+) 13.8V at 1A output + 0.5A battery charge
Battery charging Yes
Standby battery 12V 7AHr Battery
PSU output voltage 13.8V
Users 60,000
Credentials per user 4 credentials and one PIN code per user
User groups 2,000 (firmware version 1.08 or later required)
Doors on controller 1
Log events 20,000
Ethernet ports 2, maximum of 4 controllers on hub network
IP addressing DHCP/Static IP address
Door relay output 5 Amp
Auxiliary relay output 1 Amp
Main relay with inductive load 1.5A @ 30VDC or 1.5A @ 50VAC
Aux relay with inductive load 400mA @ 30VDC
Inputs Door Contact(DC), Push Button (PB/REX), AC Monitoring, Emergency Door Release (BG/EDR), Tamper
Programmable input AUXI (Interlock, Fire override, Alarm monitoring), 1
Programmable outputs OP2, OP3, 2 (100mA)
Entry and exit readers Yes (multiple up to 500mA)
Aperio locks supported per controller 16
ACT door station support (RS485) Yes (31 Door Stations)
Fire alarm override Yes
Unlock configured doors on fire input Yes
Local and global anti-passback Yes, controllers must be on the same routable network
Airlock/Interlock Yes
Arm/Disarm intruder panel Yes
PIN lockout Automatic user lockout for 5 minutes after 5 failed PIN code attempts (Card and PIN mode)

Dimensions

Dimensions 355 x 305 x 95 mm (W x L x D)

Vanderbilt V54502-C112-A100 access controller, front view

Vanderbilt ACTpro-1500PoE Access Controller, Single Door IP, PoE++ PSU V54502-C112-A100

What this controller is for

Every access controlled door needs a decision point. It reads the credential, checks the user's rights and switches the lock.

This Vanderbilt unit does that for one door, and it takes power over the network cable. It suits a door where running a separate mains supply would be awkward, or a site adding doors over time.

How it works

  • IP controller: it connects over a data network, using DHCP or a static IP address, rather than a dedicated control cable.
  • PoE: Power over Ethernet sends power and data down one network cable. The PSU in this enclosure turns that input into a 13.8V output for the door.
  • Dual port switch: the 2 Ethernet ports let controllers pass the network along, with a maximum of 4 controllers on a hub network.
  • OSDP: a reader connection standard. Secure communications use 128bit AES encryption with Vanderbilt OSDP readers.

Where to use it

It is an internal, surface mounted unit rated -10 to +40 (operating) at 75% RH non-condensing, so plan a dry location such as a comms cupboard, and check warm plant rooms first.

On an escape route, the fire alarm override and fire input are wiring options, not a design. How the door releases should be settled with whoever holds the building's fire strategy.

What the figures mean in practice

  • 3A or 1A output: the output depends on the PoE class of the port feeding it. The same controller has far less power for a lock on 802.3at than on 802.3bt, so add up the lock, readers and other loads first.
  • 5 Amp and 1.5A relay figures: the door relay is rated 5 Amp, but with inductive loads such as a maglock or strike the main relay figure is 1.5A @ 30VDC or 1.5A @ 50VAC. Use the lower figure for a lock.
  • 20,000 log events: this is how many events the controller can hold in its log.
  • Automatic lockout: in Card and PIN mode, 5 failed PIN code attempts lock the user out for 5 minutes.

Installing it

  • Space and weight: allow for 355 x 305 x 95 mm and a gross weight of 3.06 kg, and use the space in the enclosure for cable management.
  • Tamper: the 1.2 mm steel case has both lid opening and rear tamper detection, so the rear switch needs a sound fixing surface.
  • Firmware: 2,000 user groups need firmware version 1.08 or later, and EDR or deadbolt monitoring needs FW 1.09.06 or later. Check the version on site before relying on those functions.
  • Readers: entry and exit readers are supported, multiple up to 500mA in total, so add up reader current before wiring.

Planning your system

The controller is one part of the door. The job also needs a lock, such as maglocks or electric strikes, a reader, an exit device, a suitable PoE switch and usually a standby battery.

  • Readers: The controller supports ACT readers, Vanderbilt and HID OSDP readers, and third-party Wiegand and Clock&Data readers. Check the credential type before ordering.
  • Adding a door: the ACTpro-120 door station comes with 2Amp 12V DC PSU, and this controller supports ACT door stations over RS485.
  • More inputs and outputs: the ACTpro-IOM is an IO module, with 8 Inputs and 8 Outputs.

The access control system guide covers fail safe and fail secure locks and escape route rules. Vanderbilt's other parts are grouped under Vanderbilt products, and comparable units sit under access controllers and panels.

Vanderbilt V54502-C112-A100 access controller, front view
Vanderbilt

Vanderbilt ACTpro-1500PoE Access Controller, Single Door IP, PoE++ PSU V54502-C112-A100

£536.24 £643.49

The Vanderbilt V54502-C112-A100 (ACTpro-1500PoE) is an access controller for one door, powered through its PoE++ PSU rather than mains. It suits installers who already run network cable to the door location. It supports 60,000 users, has 2 Ethernet ports and sits in a steel enclosure.

Key features

For installers

Frequently asked questions

What does an access controller do?

It decides whether a credential opens the door, then switches the lock. This one is a single door IP controller with PoE++ PSU.

Does it need a mains supply?

No. Its power comes from the PoE input, through the PSU in the enclosure.

Can an ordinary PoE switch power it?

It depends on the load. A PoE 802.3at input gives 13.8V at 1A output, while 802.3bt gives 13.8V at 3A output, so match the switch to the lock and readers. Check with Vanderbilt before relying on a plain 802.3af port.

Is a battery included?

Check before ordering, and allow for one if you need standby. The standby battery is a 12V 7AHr Battery, and battery charging is supported.

Does it work with non-Vanderbilt readers?

Usually yes, if the reader uses a supported format. It takes HID OSDP readers and 3rd Party Wiegand and C&D readers.

Can it be fitted outside?

No. It is for surface mounting, Internal Use only.

View product