Vanderbilt ACTpro-1500PoE Access Controller, Single Door IP, PoE++ PSU V54502-C112-A100
About this product
The Vanderbilt V54502-C112-A100 (ACTpro-1500PoE) is an access controller for one door, powered through its PoE++ PSU rather than mains. It suits installers who already run network cable to the door location. It supports 60,000 users, has 2 Ethernet ports and sits in a steel enclosure.
Key features
- One network cable can power the door – PoE 802.3bt gives 13.8V at 3A output + 0.5A battery charge
- Room for a large user list – 60,000 users, each with 4 credentials and one PIN code
- Can grow with the site – systems that need to grow up to 4,000 doors
- Network ready – 2 Ethernet ports, with DHCP or static IP addressing
- Works with fire alarm wiring – fire alarm override, and unlock configured doors on fire input
- Flags faults – front and rear tamper detection, plus a PSU fault output
- Handles wireless locks too – 16 Aperio locks supported per controller
For installers
- Power: PoE input. 802.3bt gives 13.8V at 3A output and 802.3at gives 13.8V at 1A output, each + 0.5A battery charge. Standby battery: 12V 7AHr Battery.
- Mounting: surface mounting, Internal Use only. 355 x 305 x 95 mm, net weight 2.84 kg.
- Cabling: inputs for Door Contact(DC), Push Button (PB/REX), AC Monitoring, Emergency Door Release (BG/EDR) and Tamper. Relay limits with inductive loads are 1.5A @ 30VDC or 1.5A @ 50VAC on the main relay.
- Compatibility: compatible with all ACT readers, Vanderbilt and HID OSDP readers, and 3rd Party Wiegand and C&D readers.
- Standards: Directive 2014/30/EU and Directive 2011/65/EU. RoHS, Reach and WEEE: Yes.
Frequently asked questions
What does an access controller do?
It decides whether a credential opens the door, then switches the lock. This one is a single door IP controller with PoE++ PSU.
Does it need a mains supply?
No. Its power comes from the PoE input, through the PSU in the enclosure.
Can an ordinary PoE switch power it?
It depends on the load. A PoE 802.3at input gives 13.8V at 1A output, while 802.3bt gives 13.8V at 3A output, so match the switch to the lock and readers. Check with Vanderbilt before relying on a plain 802.3af port.
Is a battery included?
Check before ordering, and allow for one if you need standby. The standby battery is a 12V 7AHr Battery, and battery charging is supported.
Does it work with non-Vanderbilt readers?
Usually yes, if the reader uses a supported format. It takes HID OSDP readers and 3rd Party Wiegand and C&D readers.
Can it be fitted outside?
No. It is for surface mounting, Internal Use only.
-
Download
- V54502-C112-A100 datasheet
Specifications
Dimensions
Specifications
| Brand | Vanderbilt |
|---|---|
| Model | V54502-C112-A100 |
| Manufacturer Part Number (MPN) | V54502-C112-A100 |
| Also listed as | ACTpro-1500PoE |
| Product type | ACTpro-1500PoE, single door IP controller with PoE++ PSU |
| Controller input voltage | 9-28V DC |
| Controller current consumption | 350mA (Max) |
| Operating environment | Surface mounting, Internal Use only |
| Environmental temperature | -10 to +40 (operating) 75% RH non-condensing |
| Gross product weight | 3.06 kg |
| Net product weight | 2.84 kg |
| Size (W x L x D) | 355 x 305 x 95 mm |
| Enclosure material | 1.2 mm steel gray powder coated |
| LED status indicators | Yes |
| PSU fault output | Yes |
| Lid opening tamper detection (front) | Yes |
| Rear tamper detection | Yes |
| MTBF | 50,000 hr |
| PoE 802.3bt input (PoE Ultra / PoE++) | 13.8V at 3A output + 0.5A battery charge |
| PoE 802.3at input (PoE+) | 13.8V at 1A output + 0.5A battery charge |
| Battery charging | Yes |
| Standby battery | 12V 7AHr Battery |
| PSU output voltage | 13.8V |
| Users | 60,000 |
| Credentials per user | 4 credentials and one PIN code per user |
| User groups | 2,000 (firmware version 1.08 or later required) |
| Doors on controller | 1 |
| Log events | 20,000 |
| Ethernet ports | 2, maximum of 4 controllers on hub network |
| IP addressing | DHCP/Static IP address |
| Door relay output | 5 Amp |
| Auxiliary relay output | 1 Amp |
| Main relay with inductive load | 1.5A @ 30VDC or 1.5A @ 50VAC |
| Aux relay with inductive load | 400mA @ 30VDC |
| Inputs | Door Contact(DC), Push Button (PB/REX), AC Monitoring, Emergency Door Release (BG/EDR), Tamper |
| Programmable input | AUXI (Interlock, Fire override, Alarm monitoring), 1 |
| Programmable outputs | OP2, OP3, 2 (100mA) |
| Entry and exit readers | Yes (multiple up to 500mA) |
| Aperio locks supported per controller | 16 |
| ACT door station support (RS485) | Yes (31 Door Stations) |
| Fire alarm override | Yes |
| Unlock configured doors on fire input | Yes |
| Local and global anti-passback | Yes, controllers must be on the same routable network |
| Airlock/Interlock | Yes |
| Arm/Disarm intruder panel | Yes |
| PIN lockout | Automatic user lockout for 5 minutes after 5 failed PIN code attempts (Card and PIN mode) |
Dimensions
| Dimensions | 355 x 305 x 95 mm (W x L x D) |
|---|
Vanderbilt ACTpro-1500PoE Access Controller, Single Door IP, PoE++ PSU V54502-C112-A100