Fire & Safety Equipment
Fire safety equipment is the hardware of a building's fire alarm: detectors and manual call points that start an alarm, the control panel that processes it, and the sounders, beacons and visual alarm devices that warn the people inside. This collection covers conventional and addressable panels by C-TEC, Advanced and Kentec and ESP's MAG range, plus detectors, call points, interfaces, power supplies, fire extinguishers and extinguisher signs.
1-Loop 16-Zone Addressable Fire Alarm Panel, CAST Protocol, EN54-4 PSU, XFP501E/CA
EN54 Certified£ 387 84RRP: £416.69A3 CCTV Warning Sign, Data-Compliant PVC, Black/Yellow on White, HAY-WSA3
A3 Size£ 5 44RRP: £6.53Fast delivery Tomorrow, 24 NovA4 Fire Document Box, Lockable, 1.2mm Steel, Low Profile, A4-DOC-BOX-R-FIRE
Fire Docs£ 17 19RRP: £20.63Fast delivery Tomorrow, 24 NovActiV Ceiling Base Sounder + VAD, 96 dB, EN54-3/23 BF456C/CC/W
96dB Sounder£ 45 51RRP: £48.89Fast delivery Tomorrow, 24 NovActiV Diode Detector Base C4408D - Schottky Diode, 2-Wire, IP42
EN54 Certified£ 3 41RRP: £3.67Fast delivery Tomorrow, 24 NovActiV Hi-Output Wall Sounder + VAD BF433C/CC/DR - EN54-3/23, 100 dB, Deep Base
100 dB Output£ 48 81RRP: £52.44Addressable Ceiling Base Sounder + VAD, 96 dB, C-3-8 VAD, BF456A/CX/W
Loud & Clear£ 57 48RRP: £61.75Fast delivery Tomorrow, 24 NovAddressable Ceiling Sounder with VAD, 91 dB, BF451A/CX/SW
90dB Sounder£ 56 57RRP: £60.77Fast delivery Tomorrow, 24 NovAddressable Fire Alarm Panel, 1 Loop 16 Zones, Apollo XP95/Discovery, Integral 27 V PSU, XFP501E/X
LPCB Certified£ 498 31RRP: £535.38Addressable Rate-of-Rise Heat Detector EV-H-A1R, A1R 54°C, Evolution FSK
£ 26 14RRP: £28.08Fast delivery Tomorrow, 24 Nov- Weatherproof£ 59 60RRP: £64.04Fast delivery Tomorrow, 24 Nov
Advanced 1.5A 24V EN54-4 Fire Alarm PSU and Battery Charger, 7Ah Enclosure MXP-549
£ 178 39RRP: £214.07Advanced AXIS-PU programming unit
£ 286 50Advanced Commander BACnet Modbus Gateway, Configured IP Interface for MxPro 5 MXP-642C
£ 3,023 88RRP: £3,628.66Advanced Commander BACnet Modbus Gateway, IP Interface for MxPro 5 MXP-642
£ 2,388 23RRP: £2,865.88- £ 232 76
Choosing Fire & Safety Equipment
Fire safety equipment detects a fire and raises the alarm, and includes smoke and heat detectors, call points, control panels, sounders, bells and beacons from brands such as C-TEC, ESP, Klaxon and Vimpex. A fire alarm is specified as a matched set: detection, a control panel, warning devices and a power supply, drawn from ranges that work with one another.
Conventional, two-wire or addressable
Conventional panels, such as the MAG4 and C-TEC CFP708-4, group devices into zones so the panel shows which area is in alarm. In a two-wire system, detectors and sounders share one pair of cores per zone; the ESP MAGDUO2, MAGDUO4 and MAGDUO8 are 2-wire panels. Addressable panels, such as the MAGPRO16 or the 1-loop 16-zone XFP501E, identify each device on a loop.
Protocol matters
On an addressable system, a loop device must speak the panel's protocol. The C-TEC XFP501E comes in CAST (XFP501E/CA), Apollo XP95/Discovery (XFP501E/X) and Hochiki (XFP501E/H) versions, and the detectors, call points and interfaces fitted to it must match.
Warning devices
Wall and ceiling sounders, sounder beacons and combined sounder VAD bases come in red and white, with weatherproof deep-base versions for outdoor walls.
| Device | Role | Example | Standard |
|---|---|---|---|
| Smoke detector | Senses smoke | C-TEC CA416 | EN54-7 |
| Heat detector | Fixed temperature or rate of rise | C-TEC C4403A1R | EN54-5 |
| Manual call point | Raises the alarm by hand | C-TEC CA470 | EN54-11 |
| Sounder | Audible warning | C-TEC BF431C/CC/W | EN54-3 |
| Visual alarm device | Visible warning | Apollo 55000-745APO | EN54-23 |
| Input/output module | Inputs and outputs on the loop | Cygnus SN.IOU00.1 | EN 54-18 |
| Power supply | Powers panel and devices | Haydon HAY-PSUEN54-5A | EN54-4 |
Standards & compliance
The Cygnus SN.IOU00.1 input output unit is certified to EN 54-18, and the C-TEC CFP708-4 panel has certified compliance with EN54.
Brands we stock in Fire & Safety Equipment
3E Security, Acre, Advanced, Aico, Airsense, Ajax, Apollo Fire, Aritech, Axis Communications, Bell System, Bull, C-TEC, Comelit PAC, CQR, Cranford Controls, Cygnus, Dahua Technology, Eaton, Elmdene, EMS, ESP, Fike, FireClass, Haes Technologies, Haydon, Hikvision, Hochiki, Honeywell Commercial Security, Honeywell Fire Systems, Hoyles, KAC by Honeywell, Kentec Electronics, Kidde, Klaxon, Knightsbridge, Labor Strauss, LINIAN, Luminite, Mercury, Morley-IAS, Nittan, Notifier, Opus Technologies, Protect, Pyronix, RGL Electronics, Safety Technology International, Scope, System Sensor, Takex, Texecom, Videx, Vimpex, Winland Electronics, Xtralis by Honeywell and Zeta.
Vimpex supplies the most products.
Related categories
Browse by type: fire alarm systems, fire detectors and manual call points. Escape lighting is in emergency lighting.
Frequently asked questions
How does a fire detection system work?
A fire detection system uses automatic detectors to sense smoke or heat and report it to a control panel, which then sounds the alarm. Smoke detectors react to particles in the air, while heat detectors respond to a set temperature or a rapid rise. Manual call points let people raise the alarm by hand. The panel can also signal other equipment through interface modules.
What equipment makes up a fire alarm system?
A fire alarm system usually has four parts: detection, a control panel, warning devices and a power supply. Detectors and call points trigger the alarm, the panel decides how to respond, and sounders, beacons or visual alarm devices alert occupants. Choose parts designed to work together, and check that devices are certified to the relevant part of EN 54. The range here includes panels, detectors, call points and sounders.
What is fire safety equipment?
Fire safety equipment is the hardware that warns people of a fire and helps them respond safely. It includes alarm equipment such as detectors, panels and sounders, as well as fire extinguishers and safety signs. The right mix depends on the building, how it is used and its fire risk assessment. The range here includes fire alarm equipment, extinguishers and extinguisher signs.
Why buy from West Midlands Electrics
- Established 1975
- Birmingham trade counter
- UK-only supply
Updated